QIAsymphony RGQ

用于整合的自动纯化、反应体系构建和检测,满足分子检测所需

Products

QIAsymphony SP核酸提取纯化分析仪应与可与其兼容的QIAsymphony Kits配合使用,适用于试剂盒使用手册中指定的应用。QIAsymphony AS应与可与其兼容的QIAGEN Kits配合使用,适用于试剂盒使用手册中指定的应用。如果将QIAsymphony AS 与非QIAGEN的试剂盒配合使用,用户应自行确认是否适用于相关应用。Rotor-Gene Q实时荧光定量PCR分析仪应与可与其兼容的QIAGEN Kits配合使用,适用于试剂盒使用手册中指定的应用。如果将Rotor-Gene Q实时荧光定量PCR分析仪与非QIAGEN的试剂盒配合使用,用户应自行确认是否适用于相关应用。
Image
QIAsymphony RGQ MDx (US)

Cat. No. / ID:  9002341

QIAsymphony SP, QIAsymphony AS, Rotor-Gene Q MDx, Rotor-Gene AssayManager software; includes required accessories and consumables, installation, and training; includes 1-year warranty on parts and labor
Copy order details
Image
artus basic (US) plug-in for Rotor-Gene AssayManager

Cat. No. / ID:  9022910

Compact disc (CD) containing artus basic (US) plug-in for Rotor-Gene AssayManager
Copy order details
Image
QIAsymphony DSP Virus/Pathogen Mini Kit

Cat. No. / ID:  937036

For 192 preps (200 µl each): includes 2 reagent cartridges and enzyme racks and accessories
Copy order details
US$1,508.00
Image
QIAsymphony Cabinet SP/AS

Cat. No. / ID:  9020246

Accessory for correct positioning of the QIAsymphony SP/AS instruments
Copy order details

Features

  • 前所未有的灵活性
  • 优化的操作流程,高实用性
  • 易于操作,提供最大程度的便利性
  • 监控分析和实验室开发测试
  • 适合多种应用

Product Details

新的QIAGEN工作流程包括用于样本制备的QIAsymphony SP核酸提取纯化分析仪、用于反应体系构建的QIAsymphony AS以及在Rotor-Gene Q实时荧光定量PCR分析仪上进行的一系列即用型分析。QIAGEN将进一步研发、拓展QIAsymphony系列产品。

Performance

QIAsymphony RGQ配合artus QS-RGQ Kits,应用于多种高灵敏度、高特异性检测:

Principle

QIAsymphony RGQ可处理多达96个样本,从样本到结果只需一次完整的自动化运行,节省时间。一系列专门的试剂盒可组成分子检测的开放或封闭系统。

QIAsymphony SP/AS仪器和Rotor-Gene Q实时荧光定量PCR分析仪配合形成了一个可自动完成工作流程的完整系统。QIAsymphony SP核酸提取纯化分析仪可自动完成各种类型样本的制备。QIAsymphony AS确保构建的PCR反应体系高度可靠且重复性好,适合每日需要进行复杂PCR分析的实验室。QIAsymphony AS可对每次运行或样本进行多重体系构建,支持artus QS-RGQ的产品,完全兼容CE-IVD标准的工作流程,也支持自己设定的工作流程。Rotor-Gene Q实时荧光定量PCR分析仪可配合CE-IVD-marked的artus QS-RGQ试剂盒或自己设定的工作流程进行敏感、精确的real-time PCR分析。

在QIAsymphony RGQ上完全兼容CE-IVD标准的试剂盒
试剂盒仪器方法
QIAsymphony DSP Virus/Pathogen KitsQIAsymphony SP核酸提取纯化分析仪从多种类型的样本中纯化病毒核酸或细菌DNA
artus QS-RGQ KitsQIAsymphony ASReal-time PCR(多重;样本和内参)
在QIAsymphony RGQ上适合自己设定工作流程测试的试剂盒
应用试剂盒仪器方法
纯化QIAsymphony DSP Virus/Pathogen KitsQIAsymphony SP核酸提取纯化分析仪从各种类型样本中纯化病毒核酸或细菌
QIAsymphony DSP AXpH DNA KitQIAsymphony SP核酸提取纯化分析仪从细胞培养悬浮液中纯化病毒核酸或细菌
QIAsymphony Certal KitsQIAsymphony SP核酸提取纯化分析仪从生物纯化缓冲液、细胞培养悬浮液样本和疫苗制备样本中纯化宿主残留DNA和病毒核酸
反应体系构建
—病原体检测
QuantiFast Pathogen +IC KitsQIAsymphony AS使用序列特异性探针进行多重real-time PCR和RT-PCR
QuantiTect Virus KitsQIAsymphony AS可在单管中高度灵敏的检测多种病毒DNA和RNA
QIAGEN OneStep RT-PCR KitQIAsymphony AS使用任何RNA模板,简单设置,进行灵敏的RT-PCR
反应体系构建
—基因表达
Rotor-Gene SYBR® Green KitsQIAsymphony AS使用SYBR® Green I进行超快速、精确的real-time PCR和RT-PCR
Rotor-Gene Probe KitsQIAsymphony AS使用序列特异性的探针进行超快速、精确的real-time PCR和RT-PCR
Rotor-Gene Multiplex KitsQIAsymphony AS使用序列特异性的探针进行超快速、精确的多重real-time PCR和RT-PCR
反应体系构建
—残留DNA 检测
Certal Detection KitsQIAsymphony AS多重real-time PCR检测残留DNA和内参

Procedure

QIAsymphony RGQ工作流程的开始是在QIAsymphony SP仪器上纯化核酸。从样本制备流程中得到的含纯核酸的洗脱液转移到QIAsymphony AS模块,进行分析体系构建。分析样本再转移到Rotor-Gene Q实时荧光定量PCR分析仪进行PCR和数据分析。

为了满足不同工作流程需要,操作系统中有两种模式:完整模式或独立模式。在完整模式中,样本在QIAsymphony SP核酸提取纯化分析仪处理后直接转移到QIAsymphony AS,减少了手工操作步骤和记录。为了增加灵活性,QIAsymphony SP核酸提取纯化分析仪和AS也可在独立模式中进行相互独立的操作。参见"QIAsymphony workflows"。

Applications

QIAsymphony RGQ是目前和将来用于各种分子检测的最具有多功能性的系统。QIAsymphony RGQ在一个平台上整合了多种分析,也能进行自行开发测试。

适合于开放和闭合系统多种应用,包括:

  • artus移植面板(CMV、EBV、HSV、BK病毒和VZV)
  • artus血源性病毒面板(HIV、HCV和HBV)
  • 内部测试

Specifications

FeaturesSpecifications
Elution volumeQIAsymphony SP, 50–400 µl (application/protocol dependent)
FeaturesDynamic range, 12 orders of magnitude
Operating temperature15-32°C
Samples per run (throughput)Tubes 0.2 ml; Strip Tubes 0.1 ml (4 tubes); Rotor-Disc 72; Rotor-Disc 100; Up to 100 samples per run using a Rotor-Disc 100
Storage temperature5-40°C in manufacturer's package
Pollution level2
Overvoltage categoryII
HumidityRelative humidity of 15–75% (noncondensing); maximum 75% relative humidity for temperatures up to 31°C, decreasing linearly to 50% humidity at 32°C
Instrument dimensionsQIAsymphony SP, 130 x 75 x 103 cm; QIAsymphony AS, 59 x 103 x 73 cm; QIAsymphony SP/AS (integrated operation), 185 x 103 x 73 cm
ProcessingAutomated
Heat dissipation/thermal loadAverage, 0.183 kW (632 BTU/hour); Peak, 0.458 kW (1578 BTU/hour)
Input volumeQIAsymphony SP, 100-1000 µl (application/protocol dependent)
Optical SystemUp to 6 channels spanning UV to infra-red wavelengths; Excitation sources: High energy light-emitting diodes; Detector: Photomultiplier; Acquisition time: 4 s. The software allows to create new excitation/detection wavelength combinations
SoftwareRotor-Gene Q software, supplied on the installation CD provided
TechnologyQIAsymphony SP — QIAGEN magnetic-particles chemistry
Power100-240 V AC, 50-60 Hz, 1400 VA, mains supply voltage are not to exceed 10% of nominal supply voltages
Place of operationFor indoor use only
Kits or Application Packs designed for this instrumentQIAsymphony SP — QIAsymphony DSP Virus/Pathogen Kits and other QIAsymphony Kits; QIAsymphony AS — artus QS-RGQ Kits (not available in all countries), Rotor-Gene Kits and other QIAGEN real-time and end-point PCR kits
Protocols/main application on this instrumentQIAsymphony SP — Purification of DNA, RNA, bacterial and viral nucleic acids, and 6xHis-tagged protein from a wide range of starting materials; QIAsymphony AS — PCR setup.
Thermal performanceTemperature range, 35 to 99ºC; Temperature accuracy, ±0.5ºC (type, measured 30 seconds after clock start); Temperature resolution, ±0.02ºC (smallest programmable increment); Temperature uniformity, ±0.02ºC; Ramp rate (peak ramp rates, air), >15ºC/s heating, >20ºC/s cooling
Typical run time40 cycles in 45 min with the QIAGEN RG Kits (assay dependent)
WeightQIAsymphony SP, 175 kg; QIAsymphony AS, 90 kg; QIAsymphony SP/AS (integrated operation), 265 kg
Transportation conditions-25-70°C in manufacturer's package
Warranty1 year on instrument; lifetime guarantee on excitation LEDs
AltitudeUp to 2000 m (6500 ft)

Resources

安全数据表 (1)
Download Safety Data Sheets for QIAGEN product components.
Application/Protocol Documents for User-Validated Use (6)
Application/Protocol Documents for IVD Use (9)
Complex400_OBL_V4_DSP protocol

QIAsymphony DSP Virus/Pathogen Kit Protocol Sheet_V2_In Vitro Diagnostic use according to the Regulation (EU) 2017/746 on in vitro diagnostics medical devices
Cellfree500_V5_DSP protocol

QIAsymphony DSP Virus/Pathogen Kit Protocol Sheet_V2_In Vitro Diagnostic use according to the Regulation (EU) 2017/746 on in vitro diagnostics medical devices
Complex200_V6_DSP protocol

QIAsymphony DSP Virus/Pathogen Kit Protocol Sheet_V2_In Vitro Diagnostic use according to the Regulation (EU) 2017/746 on in vitro diagnostics medical devices
Complex800_V6_DSP protocol

QIAsymphony DSP Virus/Pathogen Kit Protocol Sheet_V2_In Vitro Diagnostic use according to the Regulation (EU) 2017/746 on in vitro diagnostics medical devices
Cellfree1000_V7_DSP protocol


QIAsymphony DSP Virus/Pathogen Kit Protocol Sheet_V2_In Vitro Diagnostic use according to the Regulation (EU) 2017/746 on in vitro diagnostics medical devices
Cellfree200_V7_DSP protocol

QIAsymphony DSP Virus/Pathogen Kit Protocol Sheet_V2_In Vitro Diagnostic use according to the Regulation (EU) 2017/746 on in vitro diagnostics medical devices
Complex400_V4_DSP protocol

QIAsymphony DSP Virus/Pathogen Kit Protocol Sheet_V2_In Vitro Diagnostic use according to the Regulation (EU) 2017/746 on in vitro diagnostics medical devices
Complex800_OBL_V4_DSP protocol

QIAsymphony DSP Virus/Pathogen Kit Protocol Sheet_V2_In Vitro Diagnostic use according to the Regulation (EU) 2017/746 on in vitro diagnostics medical devices
Complex200_OBL_V4_DSP protocol

QIAsymphony DSP Virus/Pathogen Kit Protocol Sheet_V2_In Vitro Diagnostic use according to the Regulation (EU) 2017/746 on in vitro diagnostics medical devices
用户使用手册 (1)

For use with QIAsymphony RGQ MDx instruments (QIAsymphony software version 5.0)

耗材文档 (1)
QIAsymphony DSP Virus/Pathogen Kit Labware List_V2_In Vitro Diagnostic use according to the Regulation (EU) 2017/746 on in vitro diagnostics medical devices
试剂盒操作手册 (1)
QIAsymphony DSP Virus/Pathogen Kit Handbook_V2_In Vitro Diagnostic use according to the Regulation (EU) 2017/746 on in vitro diagnostics medical devices
仪器技术参数 (1)
Software document for QIAsymphony software version 4.0.1
Certificates of Analysis (1)