QIAstat-Dx Rise

For higher throughput multiplex syndromic testing applications

S_1174_0_QIAstatDx_Rise_5584
Virtual Demo
Explore the virtual tour to learn more and see this product in action.

QIAstat-Dx Rise Base

Cat no. / ID.   9003163

The QIAstat-Dx Rise Base is a benchtop in vitro diagnostic device for use with QIAstat-Dx assays and QIAstat-Dx Analytical Modules. It provides full automation from sample preparation to real-time PCR detection. This higher-throughput system can accommodate up to 160 patient samples per day using 8 Analytical Modules.
InstrumentProductProduct TypePanel
QIAstat-Dx Rise Base
QIAstat-Dx Analytical Module
QIAstat-Dx Respiratory Panel Plus
QIAstat-Dx Respiratory Panel Mini
QIAstat-Dx Gastrointestinal Panel 2
QIAstat-Dx GI Panel 2 Mini B&V
QIAstat-Dx GI Panel 2 Mini B
QIAstat-Dx instruments and QIAstat-Dx panels are intended for in vitro diagnostic use. For up-to-date licensing information and product-specific disclaimers, see the respective QIAGEN kit instructions for use or user manual. QIAGEN instructions for use and user manuals are available at www.qiagen.com or can be requested from QIAGEN Technical Services (or your local distributor).
Virtual Demo
Explore the virtual tour to learn more and see this product in action.

Features

  • Uses real-time PCR to deliver comprehensive results for up to 160 patient samples per day with 8 Analytical Modules
  • Easily view Ct values and amplification curves for all detected pathogens
  • Single-step cartridge preparation with no precision pipetting required
  • Easily load the full capacity of cartridges in just a few minutes, or add them continuously, whenever needed
  • Safely dispose of all used cartridges from the waste tray in one quick step

 

 

Product Details

QIAstat-Dx simplifies infectious disease diagnostics so you can get faster results for your patients. All you need is a patient sample, a QIAstat-Dx assay cartridge and one of our intuitive QIAstat-Dx instruments.  

QIAstat-Dx Rise is our higher-throughput powerhouse, built to fit the needs of high-demand institutions. Combined with QIAstat-Dx assay cartridges, QIAstat-Dx Rise uses multiplex PCR technology – also known as syndromic testing – to quickly survey many different pathogens in a single patient sample.  

The cartridges come ready with all reagents preloaded and use our trusted assay chemistry. The system includes random access and batch testing options, with a daily capacity of 160 samples using 8 Analytical Modules. The QIAstat-Dx Rise also includes a multi-test front drawer that can process up to 16 cartridges at the same time, and 2 additional slots for urgent testing. When the test is done, all used cartridges are automatically disposed in the dedicated waste drawer. 

Each instrument is made up of two components: 1) A QIAstat-Dx Rise Base, which contains the intuitive touch-screen interface and robotic system that moves and scans the cartridges within the device and 2) up to 8 Analytical Modules, letting you test up to eight samples at once.  

With QIAstat-Dx Rise in your lab, you can get:

  • Scalable, high-throughput testing

With scalability up to 8 Analytical Modules, QIAstat-Dx Rise adapts to your needs – automating up to 160 tests daily. 

  • Smart drawer system for efficient processing

Load up to 16 cartridges at once – start new tests anytime and prioritize urgent samples without disruption. 

  • Versatility that matches your workflow

Choose between targeted or syndromic panels – all on a single platform designed for diagnostic flexibility. 

Plus, every QIAstat-Dx Analytical Module is compatible with both QIAstat-Dx Analyzer 2.0 and QIAstat-Dx Rise. Easily update your QIAstat-Dx testing format based on your evolving testing needs. Click here to know more about QIAstat-Dx Analyzer 2.0, our modular system perfect for labs of every size. 

Principle

QIAstat-Dx Rise, combined with QIAstat-Dx assay cartridges, uses real-time PCR to detect pathogen nucleic acids in human biological samples. The instrument and cartridges are designed as a closed system that contains on board all necessary reagents, enabling hands-off sample preparation. Detected real-time amplification signals are interpreted by the integrated software and are reported via an intuitive user interface.

Procedure

Preparing a QIAstat-Dx cartridge using liquid transfer is efficient and fast. And once the cartridges are ready, it takes just a few minutes to load the full capacity of cartridges and start a run on QIAstat-Dx Rise.  

Loading a sample into the QIAstat-Dx cartridge requires less than one minute of hands-on time with no precision pipetting. 

Using the provided transfer pipette, the user applies a liquid sample to the main port of the QIAstat-Dx cartridge (see  Applying a liquid sample to the QIAstat-Dx cartridge).  

Following the instructions on the QIAstat-Dx Rise touchscreen display, the user loads the prepared cartridges into the instrument’s loading tray (see  Adding cartridges to the QIAstat-Dx Rise input tray).  

The QIAstat-Dx Rise will automatically scan the sample ID and cartridge barcodes, or the user can manually scan the barcodes. Once the user starts the run, the QIAstat-Dx Rise will autonomously process the samples.  

The input tray also offers random and continuous access, meaning up to 2 additional tests can be added to an ongoing run at a moment’s notice.  

Once the run is finished, the used cartridges are automatically placed in the dedicated waste tray so they can be disposed of safely and quickly.

Applications

QIAstat-Dx Respiratory Panel Plus: Our FDA-cleared test to analyze 21 viral and bacterial targets for common pathogens causing respiratory symptoms, including SARS-CoV-2. 

QIAstat-Dx Respiratory Panel Plus – 21 bacterial and viral pathogens
Viruses   Bacteria
Severe Acute Respiratory Syndrome Coronavirus (SARS-CoV-2)  Parainfluenza virus 1

Mycoplasma pneumoniae

Bordetella pertussis

Chlamydophila pneumoniae

Influenza A Parainfluenza virus 2

 

Influenza A H1N1 pdm09 Parainfluenza virus 3

 

Influenza A H1 Parainfluenza virus 4  
Influenza A H3 Adenovirus  
Influenza B Respiratory syncytial virus  
Human Coronavirus 229E Human metapneumovirus   
Human Coronavirus HKU1 Human Rhinovirus/Enterovirus (not differentiated)  
Human Coronavirus NL63    
Human Coronavirus OC43     

This version of our assay replaces the QIAstat-Dx Respiratory SARS-CoV-2 Panel. 

QIAstat-Dx Respiratory Panel Mini: Our FDA-cleared test to analyze 5 viral targets for common pathogens causing respiratory symptoms, including human rhinovirus. This targeted panel is ideal for low-risk patients.

QIAstat-Dx Respiratory Panel Mini – 5 viral targets 
Viruses
Severe Acute Respiratory Syndrome Coronavirus (SARS-CoV-2)   
Influenza A   
Influenza B 
Respiratory syncytial virus 
Human Rhinovirus 

The QIAstat-Dx Respiratory Panel Plus can be used on the QIAstat-Dx Analyzer 1.0, QIAstat-Dx Analyzer 2.0 and QIAstat-Dx Rise.

QIAstat-Dx Gastrointestinal Panel 2: Our FDA-cleared test to analyze 16 bacterial, viral and parasitic targets for common pathogens causing gastrointestinal symptoms using preserved stool samples (Para-Pak C&S and FecalSwab). This is our extended panel for high-risk, inpatient testing.

QIAstat-Dx Gastrointestinal Panel 2 – 16 bacterial, viral and parasitic targetsCaption
Bacteria Viruses Parasites
  • Campylobacter (C. jejuni, C. coli and C. upsaliensis)
  • Shigella/Enteroinvasive Escherichia coli (EIEC)
  • Enteropathogenic Escherichia coli (EPEC)
  • Enterotoxigenic Escherichia coli (ETEC) It/st
  • Shiga-like toxin-producing Escherichia coli (STEC) stx1/stx2 (including specific identification of E. coli O157 serogroup within STEC)
  • Salmonella
  • Plesiomonas shigelloides
  • Yersinia enterocolitica
  • Adenovirus F40/41
  • Astrovirus
  • Norovirus GI/GII
  • Rotavirus A
  • Cryptosporidium
  • Cyclospora cayetanensis
  • Entamoeba histolytica
  • Giardia lamblia*

The QIAstat-Dx Gastrointestinal Panel 2 is only available for use on the QIAstat-Dx Analyzer 2.0.

QIAstat-Dx Gastrointestinal Panel 2 Mini B&V: Our FDA-cleared test to analyze 4 bacterial and 1 viral target for common pathogens causing gastrointestinal symptoms using preserved stool samples (Para-Pak C&S and FecalSwab). This is our targeted seasonal panel, ideal for outpatient testing.

QIAstat-Dx GI Panel 2 Mini B&V – 5 bacterial and viral targets
Bacteria Viruses
  • Campylobacter
  • Salmonella 
  • Shiga-like toxin E. coli (STEC)
  • Shigella
  • Norovirus

The QIAstat-Dx GI Panel 2 Mini B&V is only available for use on the QIAstat-Dx Analyzer 2.0.

QIAstat-Dx Gastrointestinal Panel 2 Mini B: Our FDA-cleared test to analyze 5 bacterial targets for common pathogens causing gastrointestinal symptoms using preserved stool samples (Para-Pak C&S and FecalSwab). This is our targeted panel, ideal for outpatient testing.

QIAstat-Dx GI Panel 2 Mini B – 5 bacterial targets
Bacteria
  • Campylobacter
  • Salmonella
  • Shiga-like toxin E. coli (STEC)
  • Shigella
  • Yersinia enterocolitica

The QIAstat-Dx GI Panel 2 Mini B is only available for use on the QIAstat-Dx Analyzer 2.0.

QIAstat-Dx Meningitis/Encephalitis Panel: Our FDA-cleared test to analyze 9 bacterial, viral and fungal nucleic acids from cerebrospinal fluid specimens obtained via lumbar puncture from individuals with signs and/or symptoms of meningitis and/or encephalitis.

QIAstat-Dx Meningitis/Encephalitis Panel – 9 bacterial, viral and fungal targets
Bacteria Viruses Fungi
  • Escherichia coli K1
  • Haemophilus influenzae
  • Listeria monocytogenes
  • Neisseria meningitidis (encapsulated)
  • Streptococcus agalactiae
  • Streptococcus pneumoniae
  • Streptococcus pyogenes
  • Enterovirus
  • Cryptococcus neoformans/gattii**

The QIAstat-Dx Meningitis/Encephalitis Panel is only available for use on the QIAstat-Dx Analyzer 1.0 and QIAstat-Dx Analyzer 2.0.

 
Features Specifications 
Configuration Modular syndromic testing system with QIAstat-Dx Rise Base, up to 8 QIAstat-Dx Analytical Modules and 1 QIAstat-Dx Rise Mobile Table (optional). 
Instrument dimensions (WxHxD) QIAstat-Dx Rise Base (door closed): 22.8 x 50.4 x 31.9 in 
QIAstat-Dx Rise Base (door open): 59 x 50.4 x 31.9 in  
QIAstat-Dx Analytical Module: 6.0 x 12.1 x 16.9 in  
QIAstat-Dx Rise mobile table: 59.1 in x 41.3 in x 29.9-31.5 in 
 
For installation and service interventions, 59 in of space around the instrument is required. 
Weight QIAstat-Dx Rise Base: 286.6 lb 
QIAstat-Dx Analytical Module: 35.3 lb 
QIAstat-Dx Rise Mobile Table (load-bearing capacity): 573.2 lb 
Power requirements  200–240 VAC
Operating conditions Specifications 
Air temperature 68–82.4 ̊F
Relative humidity 20–80%
Altitude 0–7217.8 m
Place of operation Laboratory (inside)

 

Supporting data and figures

Resources

User Manuals (4)
November 2024

Download the QIAstat-Dx Analyzer 1.0 User Manual for setup, operation, maintenance & troubleshooting of QIAGEN's fast, accurate syndromic testing system.
For use with software version 1.6.x

March 2026

Essential instructions for setup, use, and maintenance of the QIAstat‑Dx Analyzer 2.0.

QIAstat-Dx Rise User Manual
PDF (6.4MB)
Download
August 2025

Your complete reference for mastering QIAstat-Dx Rise—setup, workflow, and maintenance made simple for confident diagnostics.
Safety Data Sheets (1)
Download Safety Data Sheets for QIAGEN product components.
Certificates of Analysis (1)
Kit Handbooks (5)
August 2025


Streamline respiratory diagnostics with the QIAstat-Dx Respiratory Panel Plus—accurate results and clear Instructions for Use for confident testing.
For use with QIAstat-Dx Analyzer 1.0, QIAstat-Dx Analyzer 2.0, and QIAstat-Dx Rise
August 2025
R5 | March 2026

Discover how to use the QIAstat-Dx Gastrointestinal Panel 2 with clear, step-by-step IFU guidance for faster, confident syndromic diagnostics.
R4 | March 2026

Streamline GI diagnostics with the QIAstat‑Dx GI Panel 2 Mini B IFU, offering clear steps for rapid, reliable syndromic testing performance.
R4 | March 2026

Find QIAstat‑Dx GI Panel 2 Mini B&V Instructions for Use with clear guidance on setup, sample prep, workflow steps, safety notes, and troubleshooting.
Protocols (8)
For use with QIAstat-Dx Respiratory Panel Plus (FDA) - 691224
For use with QIAstat-Dx Gastrointestinal Panel 2 (FDA) - 691421
For use with QIAstat-Dx GI Panel 2 Mini B (FDA) - 691423
For use with QIAstat-Dx GI Panel 2 Mini B&V (FDA) - 691424
For use with QIAstat-Dx Respiratory Panel Mini (FDA) - 691218

FAQ

Can QIAstat-Dx Analyzer 2.0 connect to HIS (Hospital Information System) and LIS (Laboratory Information System)?

Yes. QIAstat-Dx Analyzer 2.0 can be connected to an HIS/LIS system. Please refer to QIAstat-Dx Analyzer 2.0 User Manual for more information regarding HIS/LIS connectivity.

The LIS Interface Specification Guide is available upon request to QIAGEN Technical Service.

For security considerations regarding the connection, please see QIAstat-Dx Analyzer 2.0 Security and Privacy Guide.

 

 

FAQ-4175
How can I save the data/results?

We strongly recommend that you perform regular system backups according to your organization's policy for the availability of data and protection from data loss. Please see QIAstat-Dx Analyzer 2.0 User Manual for instructions regarding system backup.

Assay data can be saved as a Result Report in PDF to an external USB storage device or for printing.

Selected results can be archived with a subsequent removal option to free memory space on QIAstat-Dx Analyzer 2.0 and/or to support your organization's policy on data retention.

 

FAQ-4176
Can I use any USB storage device on QIAstat-Dx Analyzer 2.0?
QIAstat-Dx Analyzer 2.0 is delivered with a USB storage device which should preferably be used for short-term data storage and general data transfer. It should have the FAT32 format type. Please refer to QIAstat-Dx Analyzer 2.0 Security and Privacy Guide for security considerations.
FAQ-4177
Can QIAstat-Dx Analyzer 2.0 connect to a printer?

Yes. You can connect a printer directly via USB or have a network printer connected via ethernet. Please see QIAstat-Dx Analyzer 2.0 User Manual for the list of recommended and tested printers. 

Additional guidance regarding printer setup troubleshooting and avoiding common printer issues is available upon request. Please contact QIAGEN Technical Service.

FAQ-4178
What happens if the administrator forgets the password? How can the password be reset on QIAstat-Dx Analyzer 2.0?
The user has 3 attempts to enter the correct password. If a user forgets their password, a system administrator can reset it. If the administrator forgets their password, it can only be reset by QIAGEN. This would require an onsite visit by a QIAGEN service engineer. Therefore, we recommend that you create an additional administrator account.
FAQ-4179
How often should I change the air filter on QIAstat-Dx Analyzer 2.0?
The air filter must be replaced every year to ensure appropriate airflow rate inside the unit. Please see QIAstat-Dx Analyzer 2.0 User Manual for instructions regarding air filter change.
FAQ-4180
What is the part number for the QIAstat-Dx air filter in order to replace it?
The catalog number for the air filter is 9026189, Air Filter Tray, AM, QSTAT.
FAQ-4181
Any recommendations for detergents that can be used for cleaning QIAstat-Dx Analyzer 2.0?
QIAstat-Dx Analyzer 2.0 User Manual details the cleaning procedure for the instrument. We recommend using a mild non-abrasive detergent to clean the surfaces.
FAQ-4182
How can we verify the QIAstat-Dx panels?

We have guidelines for laboratory verification of QIAstat-Dx panels performance. Please see Application Notes in this product page to find the applicable resource.

External controls can be purchased separately. Quality control requirements should be performed in conformance with local, state, and/or federal regulations or accreditation requirements and your laboratory's standard quality control procedures.

FAQ-4183
How can we install/uninstall or pack/unpack the Analytical Module (AM)?

Please watch these video tutorials for details:

Installing the AM

QIAstat-Dx instruction video - Installation

Uninstalling the AM

QIAstat-Dx instruction video – Uninstallation

FAQ-4184