QIAcuity RCL Quant Kit

For the detection of Replication Competent Lentivirus (RCL) with high accuracy using the QIAcuity digital PCR instruments

S_1084_5_GEN_disclaimer

✓ 24/7 automatic processing of online orders

✓ Knowledgeable and professional Product & Technical Support

✓ Fast and reliable (re)-ordering

QIAcuity RCL Quant Kit

Cat no. / ID.   250322

This kit includes: QIAcuity MasterMix, QN Internal Control DNA dPCR, QN IC Probe Assay, VSV-G Assay, Positive Control and RNase-free water
US$2,200.00
Log in To see your account pricing.

✓ 24/7 automatic processing of online orders

✓ Knowledgeable and professional Product & Technical Support

✓ Fast and reliable (re)-ordering

Features

  • Premixed master mix with positive and internal controls for easy set-up and detection of replication competent lentiviruses (RCLs) 
  • Enables sensitive, fast and accurate detection of RCL using VSV-G assay
  • Robust assay for reliable results in the presence of high background noise without prior dilution 

 

Product Details

Lentivirus (LV) is a widely used viral vector in cell and gene therapies. However, rare recombination events within the plasmid sequences used to generate LVs can lead to the formation of replication-competent lentivirus (RCL), which can infect non-target cells and replicate, posing significant safety risks.
 
To mitigate these risks, regulatory authorities mandate rigorous quality control testing to ensure the absence of RCLs throughout the lentiviral manufacturing workflow. For instance, the FDA recommends testing sufficient supernatant to achieve at least a 95% probability of detecting RCL if present at a concentration of 1 RCL per dose equivalent.
 
Accurate detection of RCL is essential for the safety and efficacy of LV-based therapies. Digital PCR, using tools like QIAcuity RCL Quant Kit, provides unmatched sensitivity and accuracy compared to other methods, such as qPCR, making it an ideal choice for detecting RCLs.

 

Performance

QIAcuity RCL Quant Kit provides:

  • Accurate results on the absence or presence of RCL based on the detection of envelope gene sequences VSV-G (vesicular stomatitis virus G glycoprotein)
  • High sensitivity down to 0.35 copies/µL (Dynamic range of 0.35–7,500 copies/µL)
  • High linearity even in the presence of up to 10 µg gDNA without the need for prior dilution
  • Reproducible results and simplified dPCR workflow

 

Principle

The principle of the dPCR reaction in the nanoplates is described here.

QIAcuity RCL Quant Kit detects the absence or presence of RCL based on the detection of envelope gene sequences VSV-G (vesicular stomatitis virus G glycoprotein). It also works in conjunction with dedicated QIAcuity Cell and Gene Therapy dPCR Assays for lentivirus workflow, QIAcuity Digital PCR System and QIAcuity Nanoplates, offering an end-to-end fast dPCR workflow comparable to qPCR but delivering robust detection of RCL in your samples.

 

Procedure

QIAcuity RCL Quant Kit is provided for 96 reactions and optimized for RCL detection using the VSV-G Assay and an Internal Control with the QIAcuity® MasterMix in multiplex reactions on the QIAcuity digital PCR (dPCR) instrument. The VSV-G Assay targets are detected in the Green Channel, while the Internal Control is detected in the Yellow Channel. Both assays come in a ready-to-use primer–probe mix. The QIAcuity RCL Quant Kit is compatible with PvuII restriction enzyme. 

 

Applications

QIAcuity RCL Quant Kit is designed for highly precise detection of RCLs in lentiviral manufacturing processes. 

References 

  1. U.S. Food and Drug Administration. (n.d.). Labeling for Human Prescription Drug and Biological Products – Implementing the PLR Content and Format Requirements. Retrieved from https://www.fda.gov/media/113790/download 

Resources

Quick-Start Protocols (1)
Safety Data Sheets (1)
Certificates of Analysis (1)

FAQ

Which channels are used for the RCL target and the Internal Control (IC) assays in the QIAcuity RCL Quant Kit, respectively?
The RCL VSV-G assay is measured in the Green Channel and the optional Internal Control (IC) assay is detected in the Yellow Channel. Therefore, the RCL VSV-G assay and the IC assay can be used in a duplex reaction.
FAQ ID - 4082
Which target is used for RCL detection in the QIAcuity RCL Quant Kit?
The kits detect VSV-G in the Green Channel.
FAQ ID - 4081
Which kit is recommended to isolate DNA for RCL analysis using the QIAcuity RCL Quant Kit?
We recommend the QIAamp DNA Mini Kit for DNA extraction.
FAQ ID - 4078
Do I need to use restriction enzymes with the QIAcuity RCL Quant Kit?
Yes, it is highly recommended to use PvuII to digest unfragmented genomic DNA.
FAQ ID - 4079
What is the maximum DNA input when using the QIAcuity RCL Quant Kit?
Samples with up to 10 µg per reaction of total DNA can be used. Samples with high levels of genomic DNA should be digested with a restriction enzyme. The QIAcuity RCL Quant Kit is compatible with PvuII.
FAQ ID - 4080