PyroMark Q24 and PyroMark Q24 Advanced

For reagents and support of discontinued instruments PyroMark Q24 and PyroMark Q24 Advanced

Features

Consider upgrading to a PyroMark Q48 Autoprep System for these advantages

  • Automation of the Pyrosequencing protocol without the need for a manual process on a vacuum prep workstation
  • Up to 48 samples can be analyzed
  • Compact instrument size
  • Enabled for connectivity
  • Touch screen display that guides users through the process
S_2018_ADNA_PyroM001_s

✓ 24/7 automatic processing of online orders

✓ Knowledgeable and professional Product & Technical Support

✓ Fast and reliable (re)-ordering

PyroMark OneStep RT-PCR Kit (50)

Cat. No. / ID: 978801

For 50 reactions: QIAGEN OneStep RT-PCR Enzyme Mix, optimized QIAGEN OneStep RT-PCR Buffer, 10x CoralLoad Concentrate, 5x Q-Solution, dNTP Mix, and RNase-Free Water
€221.00
KitAssayAccessoriesReagentSoftware
PyroMark Kits
Assays and Tests
Buffers
Q24 Reagents
Consumables
PyroMark Q24 Software
PyroMark Software
Type
OneStep RT-PCR Kit
PyroMark PCR Kit
Reactions
50
200
This product contains substances regulated under REACH (EC 1907/2006 Annex XIV). The use of this product in the EU is permitted subject to an exemption (Article 56(3)). Please refer to the REACH notification and the SDS of this product, both of which can be found in the “Resources” section of this page, for more information.
The PyroMark Q24 Instrument and PyroMark Q24 Software and PyroMark Q24 Advanced Instrument and PyroMark Q24 Advanced Software are intended to be used only in combination with QIAGEN kits indicated for use with the PyroMark Q24 and PyroMark Q24 Advanced for the applications described in the kit handbooks. If the PyroMark Instruments and Software are used with other than QIAGEN kits, it is the user's responsibility to validate the performance of such product combination for any particular application.

✓ 24/7 automatic processing of online orders

✓ Knowledgeable and professional Product & Technical Support

✓ Fast and reliable (re)-ordering

Product Details

The PyroMark Q24 was discontinued in 2018. The instrument is no longer sold, but existing instruments will be supported until the end of 2025. In addition, reagents will continue to be available until the end of 2025.

To future-proof your Pyrosequencing assays, consider upgrading your work to using a PyroMark Q48 Autoprep System which is actively sold and supported by QIAGEN.

Service Plans

Pyro Q24, Full Agreement

Cat. No. / ID: 9241822

Instrument repair service for the PyroMark Q24 at regional repair center. Shipping, labor and parts included during the Full Agreement period. Loaner instrument provided within 2–3 business days. Instrument repair turnaround time of 7–10 business days. Includes one on-site Preventive Maintenance or Inspection Service during the Full Agreement period.
Pyro Q24, Preventive Subscription

Cat. No. / ID: 9243547A

One on-site Preventive Maintenance or Inspection Service visit for the PyroMark Q24, including travel, labor and parts. Includes a 10% discount on repair services during the Preventive Subscription period.
Pyro Q24, Core Agreement

Cat. No. / ID: 9245245

One-time PyroMark Q24 instrument repair performed at a regional repair center including shipping, labor, and spare parts for a period of one year. Instrument repair turnaround time of 7–10 business days. Includes one on-site Preventive Maintenance or Inspection Service and a 10% discount on additional repair service during the Core Agreement period.

Resources

Download Files (28)
Instrument methods file for use with PyroMark Q24 Advanced Software, PyroMark Q24 Advanced Reagents or PyroMark Q24 Advanced CpG Reagents, and PyroMark Q24 Cartridges marked with method 0011
Instrument methods file for use with PyroMark Q24 Advanced Software, PyroMark Q24 Advanced Reagents or PyroMark Q24 Advanced CpG Reagents, and PyroMark Q24 Cartridges marked with method 0012
Instrument methods file for use with PyroMark Q24 Advanced Software, PyroMark Q24 Advanced Reagents or PyroMark Q24 Advanced CpG Reagents, and PyroMark Q24 Cartridges marked with method 0007
Instrument methods file for use with PyroMark Q24 Advanced Software, PyroMark Q24 Advanced Reagents or PyroMark Q24 Advanced CpG Reagents, and PyroMark Q24 Cartridges marked with method 0015
Instrument methods file for use with PyroMark Q24 Advanced Software, PyroMark Q24 Advanced Reagents or PyroMark Q24 Advanced CpG Reagents, and PyroMark Q24 Cartridges marked with method 0014
Instrument methods file for use with PyroMark Q24 Software, PyroMark Gold Q24 Reagents, and PyroMark Q24 Cartridges marked with method code 0008
Instrument methods file for use with PyroMark Q24 Advanced Software, PyroMark Q24 Advanced Reagents or PyroMark Q24 Advanced CpG Reagents, and PyroMark Q24 Cartridges marked with method 0008
Instrument methods file for use with PyroMark Q24 Software, PyroMark Gold Q24 Reagents, and PyroMark Q24 Cartridges marked with method code 0013
Instrument methods file for use with PyroMark Q24 Software, PyroMark Gold Q24 Reagents, and PyroMark Q24 Cartridges marked with method code 0004
Instrument methods file for use with PyroMark Q24 Software, PyroMark Gold Q24 Reagents, and PyroMark Q24 Cartridges marked with method code 0002
Instrument methods file for use with PyroMark Q24 Advanced Software, PyroMark Q24 Advanced Reagents or PyroMark Q24 Advanced CpG Reagents, and PyroMark Q24 Cartridges marked with method 0004
Instrument methods file for use with PyroMark Q24 Software, PyroMark Gold Q24 Reagents, and PyroMark Q24 Cartridges marked with method code 0009
Instrument methods file for use with PyroMark Q24 Software, PyroMark Gold Q24 Reagents, and PyroMark Q24 Cartridges marked with method code 0011
Instrument methods file for use with PyroMark Q24 Advanced Software, PyroMark Q24 Advanced Reagents or PyroMark Q24 Advanced CpG Reagents, and PyroMark Q24 Cartridges marked with method 0005
Instrument methods file for use with PyroMark Q24 Software, PyroMark Gold Q24 Reagents, and PyroMark Q24 Cartridges marked with method code 0010
Instrument methods file for use with PyroMark Q24 Software, PyroMark Gold Q24 Reagents, and PyroMark Q24 Cartridges marked with method code 0005
Instrument methods file for use with PyroMark Q24 Advanced Software, PyroMark Q24 Advanced Reagents or PyroMark Q24 Advanced CpG Reagents, and PyroMark Q24 Cartridges marked with method 0013
Instrument methods file for use with PyroMark Q24 Software, PyroMark Gold Q24 Reagents, and PyroMark Q24 Cartridges marked with method code 0003
Instrument methods file for use with PyroMark Q24 Software, PyroMark Gold Q24 Reagents, and PyroMark Q24 Cartridges marked with method code 0012
Instrument methods file for use with PyroMark Q24 Software, PyroMark Gold Q24 Reagents, and PyroMark Q24 Cartridges marked with method code 0001
Instrument methods file for use with PyroMark Q24 Software, PyroMark Gold Q24 Reagents, and PyroMark Q24 Cartridges marked with method code 0006
Instrument methods file for use with PyroMark Q24 Advanced Software, PyroMark Q24 Advanced Reagents or PyroMark Q24 Advanced CpG Reagents, and PyroMark Q24 Cartridges marked with method 0010
Instrument methods file for use with PyroMark Q24 Advanced Software, PyroMark Q24 Advanced Reagents or PyroMark Q24 Advanced CpG Reagents, and PyroMark Q24 Cartridges marked with method 0006
Instrument methods file for use with PyroMark Q24 Advanced Software, PyroMark Q24 Advanced Reagents or PyroMark Q24 Advanced CpG Reagents, and PyroMark Q24 Cartridges marked with method 0009
Instrument methods file for use with PyroMark Q24 Advanced Software, PyroMark Q24 Advanced Reagents or PyroMark Q24 Advanced CpG Reagents, and PyroMark Q24 Cartridges marked with method 0003
Instrument methods file for use with PyroMark Q24 Software, PyroMark Gold Q24 Reagents, and PyroMark Q24 Cartridges marked with method code 0007
Instrument methods file for use with PyroMark Q24 Software, PyroMark Gold Q24 Reagents, and PyroMark Q24 Cartridges marked with method code 0014
Instrument methods file for use with PyroMark Q24 Software, PyroMark Gold Q24 Reagents, and PyroMark Q24 Cartridges marked with method code 0015
Safety Data Sheets (2)
Download Safety Data Sheets for QIAGEN product components.
Download Safety Data Sheets for QIAGEN product components.
Operating Software (4)
This version is compatible with Windows 7 and Windows 10 (64 bit) operating systems. This software may only be downloaded by registered users with a valid PyroMark Q24 software license and registered PyroMark Q24 instrument. If you do not have a valid software license, contact your QIAGEN sales representative.
Files for upgrading existing PyroMark Q24 instruments to firmware 1.5.6903
PyroMark Q24 Advanced Software version 3.0.1 is compatible with Windows 7 and Windows 10 (64 bit) operating systems. This software may only be downloaded by registered users with a valid PyroMark Q24 Advanced Software license and registered PyroMark Q24 Advanced instrument. If you do not have a valid software license, contact your QIAGEN sales representative.
PyroMark Assay Design Software version 2.0.2 is compatible with Windows 7 and Windows 10 (64 bit) operating systems. This software may only be downloaded by registered users with a valid PyroMark Assay Design Software license. If you do not have a valid software license, contact your QIAGEN sales representative.
Kit Handbooks (6)
For use with PyroMark Q48 Autoprep, PyroMark Q24 Advanced, PyroMark Q24, PyroMark Q96 ID and PyroMark Q96 MD systems
Software User Guides (1)

FAQ

Which operating system is compatible with PyroMark Q24 Advanced application software?

The new PyroMark Q24 Advanced Software (version 3.0.1) is compatible with Windows XP, Vista (32 and 64 bit), Windows 7 (32 and 64 bit), and Windows 10 (64 bit).

FAQ ID -3164
Can I order the nucleotides from PyroMark Gold Reagents separately?
The nucleotides can only be ordered as part of the PyroMark Gold Reagents which also contain enzyme and substrate mix.
FAQ ID -2827
How much space does the PyroMark Q24 instrument need?

PyroMark Q24 takes very little bench space, measuring only H420 x W390  x D525 mm.

 

FAQ ID -2098
Which analyses can be performed with the PyroMark Q96 ID software version 1.0?
The PyroMark Q96 ID software version 1.0 contains a SNP mode for simplex and multiplex entries (and Allele Quantification analyses can be performed for simplex entries) and an SQA mode for de novo sequencing analysis. This software version does not contain a CpG mode for methylation analysis, however the PyroMark CpG software v1.0 can be used.
FAQ ID -2845
Does the PyroMark CpG LINE assay target mouse transposons as well?

The PyroMark CpG LINE-1 assay is specific for human DNA and was not tested on mouse DNA.  Mouse LINE-1 elements differ slightly in sequence and may not be detected.

 

 

-1
Which analyses can be performed with the PyroMark Q96 MD software?

The PyroMark Q96 MD software contains a SNP mode for simplex and multiplex entries (and Allele Quantification analyses can be performed for simplex entries). This software version does not contain a CpG mode for methylation analysis, however the PyroMark CpG software v1.0 can be used. SQA analysis for de novo sequencing is not possible. 

See our Product Selection Guide for additional information on CpG supplementary software.

FAQ ID -2866
Can I reinstall the PyroMark Q24 software on my new computer or following an operating system upgrade, or do I need to purchase a new license?

If you need to install the PyroMark Q24 software on a new computer replacing your old one, or after you reinstall or upgrade the operating system, you can reinstall the PyroMark Q24 software without purchasing a new license.

FAQ ID - 3473

What are the changes of PyroMark Assay Design Software Version 2.0 compared to 1.0?
The new PyroMark Assay Design Software Version 2.0 contains new algorithms to facilitate CpG assay design and enables PCR and sequencing primer design for all pyroseqeuncing applications and PyroMark instruments.
FAQ ID -2849
Can PyroMark Gold reagents be vortexed?
Reconstiuted enzyme and substrate of PyroMark Gold Reagents, should not be vortexed since this could lead to conformational changes which affect the activity.
FAQ ID -2844