Looking for a quick way to design experiments?
Try the Workflow Configurator. A convenient tool to build experimental workflows and find products to match your needs.

EZ2 Connect Fx

์‹œ์•ฝ ์„ค์ •๋ถ€ํ„ฐ ์šฉ์ถœ๊นŒ์ง€ ์‹ ์› ํ™•์ธ ์• ํ”Œ๋ฆฌ์ผ€์ด์…˜์—์„œ ํ•ต์‚ฐ ์ถ”์ถœ์˜ ์—”๋“œํˆฌ์—”๋“œ ์ž๋™ํ™”๋ฅผ ์œ„ํ•ด ์‚ฌ์šฉ

S_1121_4_HID_EZ2connect_0287

โœ“ ์—ฐ์ค‘๋ฌดํœด ํ•˜๋ฃจ 24์‹œ๊ฐ„ ์ž๋™ ์˜จ๋ผ์ธ ์ฃผ๋ฌธ ์ฒ˜๋ฆฌ

โœ“ ํ’๋ถ€ํ•œ ์ง€์‹๊ณผ ์ „๋ฌธ์„ฑ์„ ๊ฐ–์ถ˜ ์ œํ’ˆ ๋ฐ ๊ธฐ์ˆ  ์ง€์›

โœ“ ์‹ ์†ํ•˜๊ณ  ์•ˆ์ •์ ์ธ (์žฌ)์ฃผ๋ฌธ

EZ2 Connect Fx System

์นดํƒˆ๋กœ๊ทธ ๋ฒˆํ˜ธ / ID.   9003220

๋ฐ€๋ด‰๋œ ์‚ฌ์ „ ์ถฉ์ „ ์นดํŠธ๋ฆฌ์ง€๋ฅผ ์‚ฌ์šฉํ•˜์—ฌ ์ตœ๋Œ€ 24๊ฐœ์˜ ๊ฒ€์ฒด์—์„œ ํ•ต์‚ฐ์„ ์ž๋™์œผ๋กœ ๋ถ„๋ฆฌํ•  ์ˆ˜ ์žˆ๋Š” ์‹คํ—˜๋Œ€ ๊ธฐ๊ธฐ๋กœ, EZ2 Connect ๋ž™ 2๊ฐœ(EZ2 Connect Fx Tip Rack ๋ฐ EZ2 Conect Fx Tip Rack โ€“ Flip Cap Tubes), EZ2 Connect Fx Cartridge Rack, ๋ถ€ํ’ˆ ๋ฐ ๊ณต์ž„ 1๋…„ ๋ณด์ฆ์ด ํฌํ•จ๋˜์–ด ์žˆ์Šต๋‹ˆ๋‹ค.
EZ2 Connect๋Š” EZ1 Kit ๋ฐ EZ1&2 Kit์™€ ํ˜ธํ™˜๋ฉ๋‹ˆ๋‹ค.
์ตœ์‹  ๋ผ์ด์„ ์Šค ์ •๋ณด ๋ฐ ์ œํ’ˆ๋ณ„ ๋ฉด์ฑ… ์‚ฌํ•ญ์€ ๊ฐ QIAGEN ํ‚คํŠธ ์•ˆ๋‚ด์„œ ๋˜๋Š” ์‚ฌ์šฉ ์„ค๋ช…์„œ๋ฅผ ์ฐธ๊ณ ํ•˜์‹ญ์‹œ์˜ค.
EZ2 Connect Fx๋ฒ•์˜ํ•™, ์‹ ์› ํ™•์ธ ๋ฐ ์นœ์ž ํ™•์ธ ๊ฒ€์‚ฌ์—์„œ ๋ถ„์ž์ƒ๋ฌผํ•™ ์‘์šฉ ๋ถ„์•ผ์— ์‚ฌ์šฉํ•˜๊ธฐ ์œ„ํ•œ ๊ฒƒ์ž…๋‹ˆ๋‹ค. ์ด ์ œํ’ˆ์€ ์งˆ๋ณ‘์˜ ์ง„๋‹จ, ์˜ˆ๋ฐฉ ๋˜๋Š” ์น˜๋ฃŒ ๋ชฉ์ ์œผ๋กœ ์‚ฌ์šฉํ•  ์ˆ˜๋Š” ์—†์Šต๋‹ˆ๋‹ค.

โœ“ ์—ฐ์ค‘๋ฌดํœด ํ•˜๋ฃจ 24์‹œ๊ฐ„ ์ž๋™ ์˜จ๋ผ์ธ ์ฃผ๋ฌธ ์ฒ˜๋ฆฌ

โœ“ ํ’๋ถ€ํ•œ ์ง€์‹๊ณผ ์ „๋ฌธ์„ฑ์„ ๊ฐ–์ถ˜ ์ œํ’ˆ ๋ฐ ๊ธฐ์ˆ  ์ง€์›

โœ“ ์‹ ์†ํ•˜๊ณ  ์•ˆ์ •์ ์ธ (์žฌ)์ฃผ๋ฌธ

ํŠน์ง•

  • ์ตœ๋Œ€ 24๊ฐœ์˜ ๊ฒ€์ฒด์—์„œ ์•ฝ 20๋ถ„(288๊ฐœ ๊ฒ€์ฒด/์ผ) ์ด๋‚ด์— DNA ๋ฐ RNA๋ฅผ ์ •์ œ
  • ์ง๊ด€์ ์ธ ํ„ฐ์น˜์Šคํฌ๋ฆฐ ์ธํ„ฐํŽ˜์ด์Šค๋กœ ์‹ ์› ํ™•์ธ ๋ฐ ๋ฒ•์˜ํ•™ ์ „์šฉ ํ”„๋กœํ† ์ฝœ์— ์‰ฝ๊ฒŒ ์•ก์„ธ์Šค
  • ์˜จ๋ณด๋“œ ์นด๋ฉ”๋ผ๋กœ ๊ฒ€์ฒด ์ถ”์  ๋ฐ ๊ฒ€์ฒด ๋ณต๊ตฌ ๊ธฐ๋Šฅ์œผ๋กœ ํ”„๋กœ์„ธ์Šค ์•ˆ์ „์„ฑ์„ ๊ทน๋Œ€ํ™”
  • ๋ฐ”๋กœ ์‚ฌ์šฉํ•  ์ˆ˜ ์žˆ๋Š” ์‚ฌ์ „ ์ถฉ์ „์‹ ๋ฒ•์˜ํ•™ ๋“ฑ๊ธ‰(ISO 18385) ์นดํŠธ๋ฆฌ์ง€๋กœ ์žฌํ˜„์„ฑ ํ™•๋ณด
  • LIMS ๋ฐ QIAsphere ์—ฐ๊ฒฐ์„ ํ†ตํ•ด ๊ฒ€์ฒด๋ฅผ ์›๊ฒฉ์œผ๋กœ ๋ชจ๋‹ˆํ„ฐ๋งํ•˜์—ฌ ๊ฒ€์‚ฌ์‹ค ์ฒ˜๋ฆฌ๋Ÿ‰ ์ฆ๊ฐ€

์ œํ’ˆ ์„ธ๋ถ€ ์ •๋ณด

EZ2 Connect Fx๋กœ ์ฒ˜๋ฆฌ๋Ÿ‰, ์žฌํ˜„์„ฑ, ์œ ์—ฐ์„ฑ ํ–ฅ์ƒ์— ๋Œ€ํ•œ ๊ฒ€์‚ฌ์‹ค์˜ ์š”๊ตฌ๋ฅผ ์ถฉ์กฑํ•˜์‹ญ์‹œ์˜ค. ์ด ์‹คํ—˜๋Œ€ ๊ธฐ๊ธฐ๋Š” ์‚ฌ์šฉ์ž๊ฐ€ ์ž˜ ์•Œ๊ณ  ์‹ ๋ขฐํ•˜๋Š” EZ1 Advanced XL ์ž์„ฑ ๋น„๋“œ ์ •์ œ ๊ธฐ์ˆ ์„ ์‚ฌ์šฉํ•˜์—ฌ ํ•œ ๋ฒˆ์— ์ตœ๋Œ€ 24๊ฐœ์˜ ๊ฒ€์ฒด๋ฅผ ์•ฝ 20๋ถ„ ๋งŒ์— ์ž๋™์œผ๋กœ ์ฒ˜๋ฆฌํ•ฉ๋‹ˆ๋‹ค. ๋ฒ„ํŠผ ํ•˜๋‚˜๋งŒ ๋ˆ„๋ฅด๋ฉด ๋‹ค์–‘ํ•œ ์ „์šฉ ์‹ ์› ํ™•์ธ ๋ฐ ๋ฒ•์˜ํ•™ ํ”„๋กœํ† ์ฝœ์— ์‰ฝ๊ฒŒ ์•ก์„ธ์Šคํ•  ์ˆ˜ ์žˆ๊ณ  ๋‹ด๋ฐฐ๊ฝ์ดˆ, ํƒ€์•ก, ํ˜ˆ์•ก, ์ ‘์ด‰ ๊ฒ€์ฒด, ๋ผˆ, ์ •์•ก ๋“ฑ ๊ด‘๋ฒ”์œ„ํ•œ ๊ฒ€์ฒด ์œ ํ˜•์—์„œ ์ˆ˜๋งŽ์€ ๋‹ค์šด์ŠคํŠธ๋ฆผ ์• ํ”Œ๋ฆฌ์ผ€์ด์…˜์„ ์œ„ํ•œ ๊ณ ํ’ˆ์งˆ DNA๋ฅผ ๋ถ„๋ฆฌํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค. ์ตœ๋Œ€ 2mL์˜ ํˆฌ์ž… ์šฉํ•ด๋ฌผ๊ณผ 20ยตL~200ยตL ๋ฒ”์œ„์˜ ์šฉ์ถœ๋Ÿ‰์„ ํ—ˆ์šฉํ•˜๋Š” ํ”„๋กœํ† ์ฝœ์„ ํ†ตํ•ด ๊ฒ€์ฒด ํˆฌ์ž… ๋ฐ ์šฉ์ถœ๋Ÿ‰์˜ ์œ ์—ฐ์„ฑ์„ ๊ฐ–์ถ˜ EZ2 Connect Fx์˜ ์ด์ ์„ ํ™œ์šฉํ•˜์‹ญ์‹œ์˜ค. ๋˜ํ•œ ์›๊ฒฉ ์—ฐ๊ฒฐ ๊ธฐ๋Šฅ์„ ํ†ตํ•ด ๊ฒ€์‚ฌ์‹ค ์™ธ๋ถ€์—์„œ๋„ ์‹คํ–‰์„ ๋ชจ๋‹ˆํ„ฐ๋งํ•˜๊ณ  ๊ธฐ๊ธฐ๋ฅผ ๊ด€๋ฆฌํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.

์„ฑ๋Šฅ

EZ2 Connect Fx๋Š” ๋‹ค์–‘ํ•œ ๊ฒ€์ฒด ์œ ํ˜•์—์„œ ํ•ต์‚ฐ ์ถ”์ถœ์„ ์™„์ „ํžˆ ์ž๋™ํ™”ํ•˜์—ฌ ๋ฒ•์˜ํ•™ ๊ฒ€์ฒด๋ฅผ ์ฒ˜๋ฆฌํ•˜๋Š” ๊ฒ€์‚ฌ์‹ค์—์„œ ์™„์ „ํžˆ ์ƒˆ๋กœ์šด ์ˆ˜์ค€์˜ ์œ ์—ฐ์„ฑ๊ณผ ํŽธ์˜์„ฑ์„ ๋‹ฌ์„ฑํ•  ์ˆ˜ ์žˆ๋„๋ก ๋„์™€์ค๋‹ˆ๋‹ค. ์ˆ˜๋™ ํ”ผํŽซํŒ… ๋‹จ๊ณ„๋ฅผ ๋Œ€ํญ ์ค„์ด๊ณ  EZ2 Connect Fx์˜ ์‚ฌ์ „ ์ถฉ์ „ ์‹œ์•ฝ ์นดํŠธ๋ฆฌ์ง€ ์‹œ์Šคํ…œ์œผ๋กœ ๋Œ€์ฒดํ•˜์—ฌ ์‹คํ—˜์˜ ์†๋„์™€ ์žฌํ˜„์„ฑ์„ ๋†’์ผ ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค. ์ตœ๋Œ€ 24๊ฐœ์˜ ๊ฒ€์ฒด๋ฅผ ๋™์‹œ์— ์ฒ˜๋ฆฌํ•˜์—ฌ ๊ฒ€์‚ฌ์‹ค ์ฒ˜๋ฆฌ๋Ÿ‰์„ ๋Š˜๋ฆฌ์‹ญ์‹œ์˜ค. EZ2 Connect Fx๋Š” LIMS ๋ฐ QIAsphere์™€๋„ ํ˜ธํ™˜๋˜๋ฏ€๋กœ ์›๊ฒฉ์œผ๋กœ ์‹คํ–‰์„ ๋ชจ๋‹ˆํ„ฐ๋งํ•˜๊ณ  ๊ธฐ๊ธฐ๋ฅผ ๊ด€๋ฆฌํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค. ์›ํ•˜๋Š” ํƒœ๋ธ”๋ฆฟ์ด๋‚˜ ์Šค๋งˆํŠธํฐ์— QIAsphere ์•ฑ์„ ์„ค์น˜ํ•˜๊ฑฐ๋‚˜ ๋…ธํŠธ๋ถ ๋˜๋Š” ๋ฐ์Šคํฌํ†ฑ ๋ธŒ๋ผ์šฐ์ €๋ฅผ ํ†ตํ•ด QIAsphere ์›น ์•ฑ์— ์ ‘์†ํ•˜๊ธฐ๋งŒ ํ•˜๋ฉด ๋ฉ๋‹ˆ๋‹ค. EZ2 Connect Fx๋Š” EZ1 Advanced XL์—์„œ ๊ฒ€์ฆ๋œ ์‹ ์› ํ™•์ธ ๋งž์ถคํ˜• ํ”„๋กœํ† ์ฝœ๊ณผ ์šฉ์ถœ๋Ÿ‰ ๊ฐ์†Œ ๋ฐ ๋Œ€์šฉ๋Ÿ‰ ์ž‘์—…๋Ÿ‰์„ ์œ„ํ•œ ์ƒˆ๋กœ์šด ํ”„๋กœํ† ์ฝœ์„ ์ œ๊ณตํ•ฉ๋‹ˆ๋‹ค. ๋™๋“ฑ์„ฑ ๊ฒ€์‚ฌ ๊ฒฐ๊ณผ, EZ2 Connect Fx๋Š” ๋‹ค์–‘ํ•œ ํˆฌ์ž… ๊ฒ€์ฒด ํฌ์„ ๋ฒ”์œ„์—์„œ EZ1 Advanced XL๊ณผ ์œ ์‚ฌํ•˜๊ฒŒ ์šฐ์ˆ˜ํ•œ DNA ์ˆ˜์œจ์„ ์ œ๊ณตํ•˜๋Š” ๊ฒƒ์œผ๋กœ ๋‚˜ํƒ€๋‚ฌ์Šต๋‹ˆ๋‹ค(๊ทธ๋ฆผ  EZ1 Advanced XL๊ณผ ๋น„๊ตํ–ˆ์„ ๋•Œ ๋™์ผํ•˜๊ฒŒ ์šฐ์ˆ˜ํ•œ DNA ์ˆ˜์œจ ์ฐธ์กฐ). ๋˜ํ•œ EZ2 Connect Fx๋Š” ์ตœํ•˜ 20ยตL๋ฅผ ํฌํ•จํ•œ ๋‹ค์–‘ํ•œ ์šฉ์ถœ๋Ÿ‰ ๋ฒ”์œ„์—์„œ ์ผ๊ด€๋œ ์„ฑ๋Šฅ์„ ๋ฐœํœ˜ํ•ฉ๋‹ˆ๋‹ค(๊ทธ๋ฆผ  ๋งค์šฐ ์ ์€ ์šฉ์ถœ๋Ÿ‰์—์„œ๋„ ์ผ๊ด€๋œ ๊ฒฐ๊ณผ ์ฐธ์กฐ).

์›๋ฆฌ

EZ2 Connect Fx๋Š” ์ฒœ๊ณต ๋ฉ”์ปค๋‹ˆ์ฆ˜์„ ์‚ฌ์šฉํ•˜์—ฌ ์‚ฌ์ „ ์ถฉ์ „ ์‹œ์•ฝ ์นดํŠธ๋ฆฌ์ง€๋ฅผ ์—ด ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค. ๊ทธ๋Ÿฐ ๋‹ค์Œ 24์ฑ„๋„ ํ”ผํŽซํ„ฐ ํ—ค๋“œ๋ฅผ ์‚ฌ์šฉํ•˜์—ฌ ๊ฒ€์ฒด์™€ ์‹œ์•ฝ์„ ํก์ธํ•˜๊ณ  ๋ถ„์ฃผํ•ฉ๋‹ˆ๋‹ค. ํ”„๋กœํ† ์ฝœ์— ๋”ฐ๋ผ ๊ฐ€์—ด์ด ํ•„์š”ํ•œ ๊ฒฝ์šฐ ์˜จ๋ณด๋“œ ๊ฐ€์—ด ์‹œ์Šคํ…œ์ด ์•ก์ฒด์˜ ์˜จ๋„๋ฅผ ์ œ์–ดํ•ฉ๋‹ˆ๋‹ค. ํ•ต์‚ฐ ๊ฒฐํ•ฉ, ์„ธ์ฒ™, ์šฉ์ถœ์€ ๋ชจ๋‘ ์ธํŒ ์ž์„ฑ ๋น„๋“œ ๊ธฐ์ˆ ์„ ํ†ตํ•ด ์•ฝ 20๋ถ„ ์•ˆ์— ์ž๋™์œผ๋กœ ์ˆ˜ํ–‰๋ฉ๋‹ˆ๋‹ค. ์ด ์›๋ฆฌ๋Š” EZ1 Advanced XL์˜ ์ž…์ฆ๋œ ๊ธฐ์ˆ ์„ ๊ธฐ๋ฐ˜์œผ๋กœ ํ•ฉ๋‹ˆ๋‹ค(๊ทธ๋ฆผ  ์ž…์ฆ๋œ EZ1 ๊ธฐ์ˆ ๋กœ ์ œ์ž‘๋จ ์ฐธ์กฐ).

์ ˆ์ฐจ

๊ธฐ๊ธฐ๋ฅผ ์ผœ๊ณ  ์‚ฌ์šฉ์ž ๊ด€๋ฆฌ ์‹œ์Šคํ…œ์„ ์‚ฌ์šฉํ•˜์—ฌ ๋กœ๊ทธ์ธํ•ฉ๋‹ˆ๋‹ค. ํ„ฐ์น˜์Šคํฌ๋ฆฐ ๋””์Šคํ”Œ๋ ˆ์ด์˜ ์ง€์นจ์— ๋”ฐ๋ผ ์‚ฌ์šฉ์ž๋Š” ๋žฉ์›จ์–ด์™€ ๊ฒ€์ฒด๋ฅผ EZ2 Connect Fx ์ž‘์—…๋Œ€์— ๋กœ๋“œํ•˜๊ณ  ์‚ฌ์ „ ์„ค์น˜๋œ ํ”„๋กœํ† ์ฝœ์„ ์„ ํƒํ•œ ํ›„ ์‹คํ–‰์„ ์‹œ์ž‘ํ•ฉ๋‹ˆ๋‹ค. ์‹คํ–‰ํ•˜๋Š” ๋™์•ˆ ๊ธฐ๊ธฐ๋Š” ํ•ต์‚ฐ์„ ๊ฒฐํ•ฉ, ์„ธ์ฒ™, ์šฉ์ถœํ•˜์—ฌ ์šฉํ•ด๋ฌผ์„ ์ •ํ™”ํ•˜๊ณ  ์‚ฌ์šฉ์ž๋Š” ๊ฒ€์‚ฌ์‹ค์„ ๋– ๋‚˜ ๋‹ค๋ฅธ ์ž‘์—…์— ์ง‘์ค‘ํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค. ์‹คํ–‰์ด ๋๋‚˜๋ฉด EZ2 Connect Fx์— ํ†ตํ•ฉ๋œ QIAsphere ์•ฑ ๋˜๋Š” LIMS๊ฐ€ ์‚ฌ์šฉ์ž์—๊ฒŒ ์‹คํ–‰์ด ์™„๋ฃŒ๋˜์—ˆ์Œ์„ ์•Œ๋ฆฌ๊ณ , ์‚ฌ์šฉ์ž๋Š” ์žฅ๋น„๋กœ ๋Œ์•„๊ฐ€ ์ •์ œ๋œ ํ•ต์‚ฐ์„ ์ˆ˜์ง‘ํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค(๊ทธ๋ฆผ  DNA ๋ฐ RNA๋ฅผ ๋ถ„๋ฆฌํ•˜๋Š” ๊ฐ„๋‹จํ•œ ์„ธ ๋‹จ๊ณ„ ์ฐธ์กฐ).

์‘์šฉ ๋ถ„์•ผ

EZ2 Connect Fx์™€ ์ ์ ˆํ•œ QIAGEN ํ‚คํŠธ๋ฅผ ์‚ฌ์šฉํ•˜์—ฌ ์ •์ œ๋œ ํ•ต์‚ฐ์€ ์‹ ์› ํ™•์ธ ๋ฐ ๋ฒ•์˜ํ•™ ๋‹ค์šด์ŠคํŠธ๋ฆผ ๋ถ„์„(์˜ˆ: PCR, qPCR, ์ฐจ์„ธ๋Œ€ ์—ผ๊ธฐ์„œ์—ด ๋ถ„์„(next-generation sequencing, NGS) ๋˜๋Š” ๋””์ง€ํ„ธ PCR(digital PCR, dPCR))์— ์‚ฌ์šฉํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค(๊ทธ๋ฆผ  ํ•˜๋‚˜์˜ ๊ธฐ๊ธฐ, ๋‹ค์–‘ํ•œ ์• ํ”Œ๋ฆฌ์ผ€์ด์…˜ ์ฐธ์กฐ).

์ง€์›๋˜๋Š” ๋ฐ์ดํ„ฐ ๋ฐ ์ˆ˜์น˜

์‚ฌ์–‘

ํŠน์ง•์‚ฌ์–‘
Sample types๋ฒ•์˜ํ•™ ๊ฒ€์ฒด: ๋ฏธ์„ธ ๊ฒ€์ฒด, ํ˜ˆ์•ก, ์ •์•ก, ํƒ€์•ก, ๋ผˆ, ๋จธ๋ฆฌ์นด๋ฝ
Protocols/main application on this instrumentTrace, ํŒ ๋Œ„์Šค, ๋Œ€์šฉ๋Ÿ‰, ๋Œ€ํ˜• ๋ผˆ, ์ •๊ทœํ™”
Pipetting range20~1000ยตL
Features์˜จ๋ณด๋“œ ํ”ผํŽซํŒ…, ๊ฐ€์—ด ๊ธฐ๋Šฅ, ์ž๋™ํ™”๋œ ์‹œ์•ฝ ์นดํŠธ๋ฆฌ์ง€ ์ฒœ๊ณต, UV-LED ์˜ค์—ผ ์ œ๊ฑฐ, ์›๊ฒฉ ์—ฐ๊ฒฐ, ํ„ฐ์น˜์Šคํฌ๋ฆฐ ๋””์Šคํ”Œ๋ ˆ์ด, ์นด๋ฉ”๋ผ
Throughput๊ฒ€์ฒด 1~24๊ฐœ
Technology์ž์„ฑ ์ž…์ž ๊ธฐ์ˆ 
Applications์ž๋™ํ™”๋œ ํ•ต์‚ฐ ์ •์ œ
Instrument dimensions57.5cm x 72cm x 56cm(๋†’์ด x ๊ฐ€๋กœ x ์„ธ๋กœ)

ํ‚คํŠธ ๋ฐ ์†Œ๋ชจํ’ˆ

Kits
Accessories
Supplementary Consumables
EZ1&2 DNA Investigator Kit (48) imageEZ1&2 DNA Investigator Kit (48) image
์นดํƒˆ๋กœ๊ทธ ๋ฒˆํ˜ธ: 952034
โ‚ฌ457.00
EZ2 DNA Investigator Sep&Prep Kit (48) imageEZ2 DNA Investigator Sep&Prep Kit (48) image
์นดํƒˆ๋กœ๊ทธ ๋ฒˆํ˜ธ: 952134
โ‚ฌ795.00
EZ1&2 DNA Blood 200 ยตl Kit (48) imageEZ1&2 DNA Blood 200 ยตl Kit (48) image
์นดํƒˆ๋กœ๊ทธ ๋ฒˆํ˜ธ: 951034
โ‚ฌ518.00
EZ1&2 DNA Blood 350 ยตl Kit (48) imageEZ1&2 DNA Blood 350 ยตl Kit (48) image
์นดํƒˆ๋กœ๊ทธ ๋ฒˆํ˜ธ: 951054
โ‚ฌ576.00
EZ1&2 Virus Mini Kit v2.0 (48) imageEZ1&2 Virus Mini Kit v2.0 (48) image
์นดํƒˆ๋กœ๊ทธ ๋ฒˆํ˜ธ: 955134
โ‚ฌ503.00
EZ1&2 DNA Tissue Kit (48) imageEZ1&2 DNA Tissue Kit (48) image
์นดํƒˆ๋กœ๊ทธ ๋ฒˆํ˜ธ: 953034
โ‚ฌ600.00
EZ1&2 ccfDNA Kit (48) imageEZ1&2 ccfDNA Kit (48) image
์นดํƒˆ๋กœ๊ทธ ๋ฒˆํ˜ธ: 954854
โ‚ฌ1,189.00

์„œ๋น„์Šค ๊ณ„ํš

EZ2 Connect, Core Agreement

์นดํƒˆ๋กœ๊ทธ ๋ฒˆํ˜ธ / ID.   9245569

1๋…„ ๋™์•ˆ ์ถœ์žฅ๋น„, ์ธ๊ฑด๋น„ ๋ฐ ๋ถ€ํ’ˆ์„ ํฌํ•จํ•œ ํ˜„์žฅ ์žฅ๋น„ ์ˆ˜๋ฆฌ ์„œ๋น„์Šค๊ฐ€ ์ œ๊ณต๋ฉ๋‹ˆ๋‹ค. ์˜์—…์ผ ๊ธฐ์ค€ 5์ผ ์•ˆ์— ๋Œ€์‘. Core Agreement ๊ธฐ๊ฐ„ ๋™์•ˆ ๊ณ„ํš๋œ ์œ ์ง€๋ณด์ˆ˜ 1ํšŒ ํฌํ•จ.

EZ2 Connect, Full Agreement

์นดํƒˆ๋กœ๊ทธ ๋ฒˆํ˜ธ / ID.   9245570

1๋…„ ๋™์•ˆ ์ถœ์žฅ๋น„, ์ธ๊ฑด๋น„ ๋ฐ ๋ถ€ํ’ˆ์„ ํฌํ•จํ•œ ํ˜„์žฅ ์žฅ๋น„ ์ˆ˜๋ฆฌ ์„œ๋น„์Šค๊ฐ€ ์ œ๊ณต๋ฉ๋‹ˆ๋‹ค. ์˜์—…์ผ ๊ธฐ์ค€ 2์ผ ์•ˆ์— ๋Œ€์‘ํ•ด ๋“œ๋ฆฝ๋‹ˆ๋‹ค. Full Agreement ๊ธฐ๊ฐ„ ๋™์•ˆ ๊ณ„ํš๋œ ์œ ์ง€๋ณด์ˆ˜ 1ํšŒ ํฌํ•จ.

๋ฆฌ์†Œ์Šค

Brochures & Guides (8)
Full Service Agreement -- Protect your investment and keep your instrument performing at its best
Make the right decisions to streamline processing of sexual assault samples with our guide to optimized workflows.

Get the most out of every sample with ultra-efficient nucleic acid extraction on EZ2 Connect Fx


Automated processing of sexual assault samples using EZ2 Connect Fx

Solutions for missing persons and bone sample processing


EZ2 Connect Fx optimizes DNA yield from difficult firearm and cartridge casings
Our improved noninvasive paternity testing workflow delivers answers with greater confidence
Operating software (7)

Software v1.3.1, Standard Protocol Package v13 (October 2026)

 

Note: Unzip the folder prior to installation on the EZ2 Connect instrument, and install the *.ez2u file only.

For more information on the installation process, refer to Section 5.4.6 (Installing New Protocols) of the EZ2 Connect and EZ2 Connect Fx User Manual.

Version 1.2.0

For more information on the installation process, please refer to Section 5.3.8 (Updating software) of the EZ2 Connect and EZ2 Connect Fx User Manual.


Software v1.2.1, Standard Protocol Package v12, and DSP Standard Protocol Package v2

Note: Unzip the folder prior to installation on the EZ2 Connect instrument, and install the *.ez2u file only.

For more information on the installation process, please refer to Section 5.3.8 (Updating software) of the EZ2 Connect and EZ2 Connect Fx User Manual.


Version 1.1.2

This is the language package corresponding to the EZ2 Connect software. For more information on the installation process, please refer to Section 5.3.7 (Language Settings) of the EZ2 Connect and EZ2 Connect Fx User Manual.


Version 8 (old version, compatible with software version 1.1)

For more information on the installation process, please refer to Section 5.3.6. (Installing New Protocols), of the EZ2 Connect and EZ2 Connect Fx User Manual.
Version 11

Note: Unzip the folder prior to installation on the EZ2 Connect instrument, and install the *.ez2u file only.

For more information on the installation process, please refer to Section 5.3.6 (Installing New Protocols) of the EZ2 Connect and EZ2 Connect Fx User Manual.
Version 10 

Note: Unzip the folder prior to installation on the EZ2 Connect instrument, and install the *.ez2u file only.

For more information on the installation process, please refer to Section 5.3.6 (Installing New Protocols) of the EZ2 Connect and EZ2 Connect Fx User Manual.
User Manuals (4)
For use with EZ1&2 DNA Investigator Kit
For use with EZ2 DNA Investigator Sep&Prep Kit
Validation & Technical Documentation (7)
This privacy and security guide will help you install, configure, operate and maintain your EZ2 Connect devices safely and securely and in compliance with your data protection regulations.

Instructions for cleaning and disinfection of EZ2 Instruments

EZ2 Off The Shelf Software (OSS) License for EZ2 Connect, EZ2 Connect Fx, and EZ2 Connect MDx
Safety Data Sheets (1)
Download Safety Data Sheets for QIAGEN product components.
Certificates of Analysis (1)

FAQ

Which protocol package needs to be installed on EZ2 Connect Fx to run the Sep&Prep protocol?
Software Version 1.2.1 (or newer) has to be installed. It is integrated into SW patch 12.
FAQ-4137
Which Sep&Prep workflow steps are automated on EZ2 Connect Fx?
After the off-deck epithelial lysis and centrifugation, the instrument does the following automated steps: removal of non-sperm fraction from the sperm pellet, a series of sperm (pellet) washes, sperm pellet lysis, Prot K inactivation resulting in elution of ready to use sperm fraction, and a non-sperm fraction ready for purification.
FAQ-4147
Do I have to wait for EZ2 Connect Fx to cool down before starting a new run?
No, one doesnโ€™t have to wait for the cooldown of the device for a re-run with Sep&Prep. When starting a run to process non-sperm or any other samples with the EZ1&2 DNA Investigator Kit shortly after an Investigator Sep&Prep run, the heating block of the instrument is still at high temperature. This may cause increased evaporation of elution buffer, which is transferred to the heating position after a protocol is started, resulting in slightly lower eluate volumes. If this is observed, wait until the heating block has cooled to a lower temperature. Note that the elution buffer is heated to 65ยฐC during a run. Thus, cooling to lower temperatures is not required.
FAQ-4148
EZ2 Connect Fx instrument crashed mid-run. How do I recover my samples?
Please refer to EZ2 Connect Fx DNA Investigator Sep&Prep Recovery Protocol User Manual (www.qiagen.com/HB-3743).
FAQ-4149