QuantiNova Reverse Transcription Kit

再現性の高い2ステップリアルタイムPCRのための迅速なcDNA合成

S_4513_QuantiNovaRT_98C9769_s

✓ 24/7 automatic processing of online orders

✓ Knowledgeable and professional Product & Technical Support

✓ Fast and reliable (re)-ordering

QuantiNova Reverse Transcription Kit (50)

Cat. No. / ID:  205411

For 50 x 20 µl reactions: 100 µl 8x gDNA Removal Mix, 50 µl Reverse Transcription Enzyme, 200 µl Reverse Transcription Mix (containing RT primers), 100 µl Internal Control RNA, 1.9 ml RNase-Free Water
Copy order details
¥44,000
KitAssay
QuantiNova Reverse Transcription Kit
QuantiNova IC Assay
Reactions
50
200
QuantiNova Reverse Transcription Kitは分子生物学的アプリケーション用であり、疾病の診断、予防、あるいは治療に使用することはできません。

✓ 24/7 automatic processing of online orders

✓ Knowledgeable and professional Product & Technical Support

✓ Fast and reliable (re)-ordering

Features

  • gDNA除去によるアーティファクトな結果の削減
  • 付属のインターナルコントロールを使用し、確実なcDNA合成のモニタリング
  • 逆転写酵素の高いアフィニティーにより幅広いリニアレンジでcDNA合成が可能

Product Details

ユニークなQuantiNova Reverse Transcription Kit はgDNA除去及び付属のインターナルコントロールを用いることで、迅速かつ簡便なcDNA合成のプロトコールを提供します。RNAサンプル中に混入しているゲノムDNAはgDNA Removal Mixによって除去され、かつ付属のInternal Control RNAによって、確実な逆転写と増幅を検証するために使用できます。QuantiNova Reverse Transcription Kit は迅速かつ効果的なcDNA合成を提供します。合成されたcDNAはリアルタイムPCRでの使用に至適化され、mRNA転写物の全ての領域を確実に定量できます。

Performance

Contaminating genomic DNA in RNA samples is effectively and rapidly removed with the unique gDNA Removal Mix. Elimination of genomic DNA is crucial for accurate gene expression results and when design of RNA-specific primers or probes is not always possible, for example, when analyzing single-exon genes. With gDNA Removal Buffer, time is saved and costs are reduced, since a separate DNase digestion during or after purification of RNA samples is not required.

The newly developed internal control is a defined transcript (RNA molecule) that can simply be added to your samples and transcribed into cDNA. It is intended to report instrument or chemistry failures, errors in assay setup and the presence of inhibitors. The expected range of Cq (CT) values can be used to test successful reverse transcription/amplification and the reproducibility of your results.

The high RNA affinity of the QuantiNova Reverse Transcriptase enables high yields of cDNA from any RNA template. Difficult templates, such as those with high GC-content or complex secondary structure, are also successfully reverse transcribed. The Reverse Transcription Mix contains a specially optimized mix of oligo-dT and random primers that enable cDNA synthesis from all regions of RNA transcripts, including 5' regions. The kit provides high yields of cDNA template for real-time PCR analysis, regardless of where the amplified target region is located on the transcript, and provides greater sensitivity in the detection of low-abundance genes.

The QuantiNova Reverse Transcription Kit offers accurate results over a wide range of input amounts, including up to 5 µg RNA in the standard protocol, which can be doubled to accommodate exceptionally large amounts of RNA.

Principle

The QuantiNova Reverse Transcriptase has a high affinity for RNA and is capable of cDNA synthesis from a wide range of RNA amounts (10 pg – 5 μg) (see figure “ Precise quantification from 5 µg – 10 pg RNA). The kit provides high yields of cDNA template for real-time PCR analysis, regardless of where the amplified target region is located on the transcript. Even difficult templates, such as those with high GC-content or complex secondary structure, are successfully reverse transcribed. The QuantiNova RT Buffer has also been optimized to be compatible with real-time PCR buffers. 

To obtain accurate results in real-time RT-PCR gene expression assays, it is important that only cDNA is amplified and detected. Interference by genomic DNA can effectively and rapidly be removed using the gDNA Removal Mix (see figure “ Efficient removal of contaminating gDNA ensures precise quantification of transcripts). Time is saved and costs are reduced, since a separate DNase digestion during or after purification of RNA samples is not required. Also, designing RNA-specific primers or probes is not necessary. 

Detecting variations in cDNA synthesis allows you to check the reproducibility of your results. The newly developed internal control is a defined transcript (RNA molecule) that can be optionally added to your samples and transcribed into cDNA. It is intended to report instrument or chemistry failures, errors in assay setup and the presence of inhibitors. Because the internal control behaves comparable to real transcripts, it can be used to confirm successful reverse transcription and amplification in subsequent qPCR (see figure “ Internal control reliably detects presence of inhibitors).
Components of the QuantiNova Reverse Transcription Kit
Component Benefits
gDNA Removal Mix Detection of RNA only in real-time RT-PCR
Internal Control RNA Verification of successful RT-PCR performance
QuantiNova Reverse Transcriptase Use of a wide range of RNA amounts (10 pg – 5 μg RNA)
High sensitivity
QuantiNova RT buffer system Read-through of difficult templates
RT Primer Mix cDNA synthesis from all regions of transcripts, even from 5' regions
See figures

Procedure

Genomic DNA removal and cDNA synthesis take only 20 minutes with the QuantiNova Reverse Transcription Kit. The kit includes everything you need for fast cDNA synthesis. 

Purified RNA is briefly incubated in gDNA Removal Mix to effectively remove contaminating genomic DNA. In contrast to other methods, the RNA sample is then used directly for reverse transcription in combination with a master mix prepared from the Reverse Transcription Mix plus Reverse Transcription Enzyme. With the QuantiNova Reverse Transcriptase, RNA can be transcribed at low temperatures, even through complex 2° degree structure. This ensures that the RNA will stay intact as the reaction takes place at 42°C and is then inactivated at 85°C. Additional steps for RNA denaturation or RNase H digestion are not necessary.

Applications

The QuantiNova Reverse Transcription Kit allows highly efficient and sensitive real-time RT-PCR for all types of starting materials, including laser-microdissected samples and tissue biopsies.

Supporting data and figures