QIAstat-Dx research

For multiplex PCR syndromic applications

Products

The QIAstat-Dx Viral Vesicular Panel and QIAstat-Dx Respiratory Panel are for research use only. Not for use in diagnostic procedures. The QIAstat-Dx Viral Vesicular Panel and QIAstat-Dx Respiratory Panel are run on the QIAstat-Dx Analyzer.
Image

QIAstat-Dx Viral Vesicular Panel

Cat no. / ID.   691731

Six individually packaged cartridges containing all reagents needed for sample preparation and multiplex real-time PCR plus internal control, including six transfer pipettes
This product contains substances regulated under REACH (EC 1907/2006 Annex XIV). The use of this product in the EU is permitted subject to an exemption (Article 56(3)). Please refer to the REACH notification and the SDS of this product, both of which can be found in the “Resources” section of this page, for more information.
Image

QIAstat-Dx Analytical Module

Cat no. / ID.   9002814

Module contains the hardware and software for sample testing and analysis.

Features

  • Intuitive workflow with minimal hands-on time
  • Uses real-time PCR to deliver comprehensive results in about an hour
  • Easily view Ct values and amplification curves for all detected pathogens
  • No precision pipetting required and unique direct swab protocol for input into the cartridge
  • QIAsphere-connected for real-time updates, proactive remote service and custom epidemiology reports

Product Details

The QIAstat-Dx Analyzer, combined with QIAstat-Dx assay cartridges, uses real-time PCR to detect pathogen nucleic acids in human biological samples. The QIAstat-Dx Analyzer and cartridges are designed as a closed system that enables hands-off sample preparation followed by detection and identification of pathogen nucleic acids. Samples are inserted into a QIAstat-Dx cartridge, which contains all the reagents to isolate and amplify nucleic acids from the sample. Detected real-time amplification signals are interpreted by the integrated software and are reported via an intuitive user interface.


Available panels utilize powerful QIAGEN sample and assay technologies, to deliver true Sample to Insight processing of even the most challenging samples.


QIAstat-Dx Viral Vesicular Panel: The QIAstat-Dx Viral Vesicular Panel can be used to detect viral nucleic acid from transport media by real-time RT-PCR. This multiplex PCR syndromic cartridge detects and differentiates 8 targets - mpox virus (MPXV) clade I*, MPXV clade II, orthopoxvirus (OPXV), herpes simplex virus (HSV) 1, HSV-2, human herpes virus 6, enterovirus and varicella zoster virus.
 
*MPXV clade I does not detect Ib samples, these samples will give a positive orthopoxvirus (OPXV) result.


QIAstat-Dx Respiratory Panel: This version of our multiplex syndromic cartridge detects and differentiates 22 respiratory targets from nasopharyngeal swabs (NPS).

 

Resources

Safety Data Sheets (1)
Download Safety Data Sheets for QIAGEN product components.
Certificates of Analysis (1)
Operating Software (3)
For use with the QIAstat-Dx Analyzer and the DiagCORE Analyzer
Checksum: 3C733E448169422E9CD41F13477C4CE02336F15B
For use with the QIAstat-Dx Analyzer and the DiagCORE Analyzer
Software User Guides (1)
For use with the QIAstat-Dx Analyzer 2.0 and software version 1.6 and higher
User Manuals (4)
For use with software version 1.2.x or higher
November 2024

For use with software version 1.5.x




November 2024

Download the QIAstat-Dx Analyzer 1.0 User Manual for setup, operation, maintenance & troubleshooting of QIAGEN's fast, accurate syndromic testing system.
For use with software version 1.6.x

March 2026

Essential instructions for setup, use, and maintenance of the QIAstat‑Dx Analyzer 2.0.

FAQ

Can QIAstat-Dx Analyzer 2.0 connect to HIS (Hospital Information System) and LIS (Laboratory Information System)?

Yes. QIAstat-Dx Analyzer 2.0 can be connected to an HIS/LIS system. Please refer to QIAstat-Dx Analyzer 2.0 User Manual for more information regarding HIS/LIS connectivity.

The LIS Interface Specification Guide is available upon request to QIAGEN Technical Service.

For security considerations regarding the connection, please see QIAstat-Dx Analyzer 2.0 Security and Privacy Guide.

 

 

FAQ-4175
How can I save the data/results?

We strongly recommend that you perform regular system backups according to your organization's policy for the availability of data and protection from data loss. Please see QIAstat-Dx Analyzer 2.0 User Manual for instructions regarding system backup.

Assay data can be saved as a Result Report in PDF to an external USB storage device or for printing.

Selected results can be archived with a subsequent removal option to free memory space on QIAstat-Dx Analyzer 2.0 and/or to support your organization's policy on data retention.

 

FAQ-4176
Can I use any USB storage device on QIAstat-Dx Analyzer 2.0?
QIAstat-Dx Analyzer 2.0 is delivered with a USB storage device which should preferably be used for short-term data storage and general data transfer. It should have the FAT32 format type. Please refer to QIAstat-Dx Analyzer 2.0 Security and Privacy Guide for security considerations.
FAQ-4177
Can QIAstat-Dx Analyzer 2.0 connect to a printer?

Yes. You can connect a printer directly via USB or have a network printer connected via ethernet. Please see QIAstat-Dx Analyzer 2.0 User Manual for the list of recommended and tested printers. 

Additional guidance regarding printer setup troubleshooting and avoiding common printer issues is available upon request. Please contact QIAGEN Technical Service.

FAQ-4178
What happens if the administrator forgets the password? How can the password be reset on QIAstat-Dx Analyzer 2.0?
The user has 3 attempts to enter the correct password. If a user forgets their password, a system administrator can reset it. If the administrator forgets their password, it can only be reset by QIAGEN. This would require an onsite visit by a QIAGEN service engineer. Therefore, we recommend that you create an additional administrator account.
FAQ-4179
How often should I change the air filter on QIAstat-Dx Analyzer 2.0?
The air filter must be replaced every year to ensure appropriate airflow rate inside the unit. Please see QIAstat-Dx Analyzer 2.0 User Manual for instructions regarding air filter change.
FAQ-4180
What is the part number for the QIAstat-Dx air filter in order to replace it?
The catalog number for the air filter is 9026189, Air Filter Tray, AM, QSTAT.
FAQ-4181
Any recommendations for detergents that can be used for cleaning QIAstat-Dx Analyzer 2.0?
QIAstat-Dx Analyzer 2.0 User Manual details the cleaning procedure for the instrument. We recommend using a mild non-abrasive detergent to clean the surfaces.
FAQ-4182
How can we verify the QIAstat-Dx panels?

We have guidelines for laboratory verification of QIAstat-Dx panels performance. Please see Application Notes in this product page to find the applicable resource.

External controls can be purchased separately. Quality control requirements should be performed in conformance with local, state, and/or federal regulations or accreditation requirements and your laboratory's standard quality control procedures.

FAQ-4183
How can we install/uninstall or pack/unpack the Analytical Module (AM)?

Please watch these video tutorials for details:

Installing the AM

QIAstat-Dx instruction video - Installation

Uninstalling the AM

QIAstat-Dx instruction video – Uninstallation

FAQ-4184