QIAcuity Nanoplate 是微流体数字 PCR 孔板,可让您以每孔最多 8500 个或 26,000 个反应分区运行 8 份、24 份或 96 份样本。所有四款纳米微孔板均旨在 QIAcuity 数字 PCR 仪器上运行。
这些纳米微孔板仅供与 QIAcuity Digital PCR System一起使用。使用 QIAgility 在 QIAcuity Nanoplate 中进行自动化液体处理和 PCR 反应体系构建时应使用专用的 QIAcuity Nanoplate 适配器。操作完成后,将该孔板加载到 QIAcuity Digital PCR System 上进行 dPCR 反应。
您想要进一步了解该产品并让我们的 dPCR 专家联系您吗?请在这里登记,我们将很快与您联系。
这些孔板经过专门设计,专供用于在 QIAcuity 仪器中进行数字 PCR 反应。QIAGEN 提供的纳米微孔板有四种类型,均为边合成边测序 (Sequencing by Synthesis, SBS) 格式,但规格有所不同,可满足不同的应用需求。
| 类型 | 框架颜色 | 规格 | 应用 |
| Nanoplate 26K 8-well | 浅蓝色 |
8 孔 x 大约 26,000 个反应分区 每孔 40 µL dPCR 反应体系 |
罕见突变检测、 液体活检、基因 表达分析、 病原体检测等。 |
| Nanoplate 26K 24-well | 蓝色 |
24 孔 x 大约 26,000 个反应分区 每孔 40 µL dPCR 反应体系 |
罕见突变检测、 液体活检、基因 表达分析、 病原体检测等。 |
| Nanoplate 8.5K 24-well | 白色 |
24 孔 x 大约 85,000 个反应分区 每孔 12 µL dPCR 反应体系 |
拷贝数变异 分析、基因表达 分析、NGS 文库 定量、基因编辑 检测等。 |
| Nanoplate 8.5K 96-well | 灰色 |
96 孔 x 大约 85,000 个反应分区 每孔 12 µL dPCR 反应体系 |
仅需 3 个简单的步骤——移液及加载、运行实验和分析结果,您就能在 2 小时内获得 dPCR 结果。有关纳米微孔板中 dPCR 反应的原理说明,请参见这里。
与 qPCR 实验一样,样本制备包括将预混液、探针和引物转移到一个 8 孔、24 孔或 96 孔纳米微孔板中,随后添加样本该系统将微分化、热循环和成像集成到单一全自动化的仪器上,使用户可在 2 小时内获得结果。您可在 Suite Software 上执行分析,该软件可针对您的靶序列及质量控制(例如阳性样本或无模板对照 [NTC])给出以每微升拷贝数表示的浓度。该分析还可在同一局域网 (LAN) 上的远程计算机上执行。
QIAcity 纳米微孔板与 QlAcuity Digital PCR System 和 QIAcity PCR 试剂盒的联合使用可让您执行各种数字 PCR 应用,包括:


Version 3.5
The QIAcuity Control Software is an integral part of the QIAcuity instrument. It provides a graphical user interface (GUI) for basic functions such as plate setup, changing the order of plates to be processed and monitoring run status in real time. When a run is complete, the data are stored in the instrument's memory and transferred to the connected QIAcuity Software Suite for analysis.
QIAcuity Control Software version 3.5 includes several improvements to enhance system security, troubleshooting and image acquisition reliability. The Control Software platform, underlying Ubuntu operating system and firmware have been updated. The upgrade to Ubuntu 22.04 LTS and .NET 10 provides access to current security patches and reduces cybersecurity risks. QIAGEN therefore recommends installing or updating to this software version.
Additional improvements include the automatic transfer of support packages to the QIAcuity Software Suite following a critical system error, reducing the need for manual transfer or support package generation. In addition, if a blurry reference image is detected, the system automatically retakes the image to support reliable image acquisition.
Detailed information about QIAcuity Control Software version 3.5 is available in the Release Notes, which can also be downloaded from the Technical Information section.
Note: The latest QIAcuity Control Software (CSW) version 3.5 is compatible only with QIAcuity Software Suite version 3.5. If only one software component is updated, a connection cannot be established between the QIAcuity Software Suite and the Control Software.
Both software are Long-Term Support (LTS) releases, and each offers an extended support period of 7 years from its respective release date.
Important: Follow the instructions provided in the QIAcuity User Manual. for software version 3.5 and in the Release Notes.
Note: In some cases, the CSW installation may fail with the message "Installation failed" due to excessive residual data on the instrument. Before retrying the update, select Force Clear under Tools > System Support in the installed CSW. Wait a few minutes for the Disk Space Usage display to update, perform the Force Clear process at least twice, and then run the update again.
It is strongly recommended to update the QIAcuity Software Suite first before proceeding with the QIAcuity Control Software.
Note: After you click Reboot during a Control Software upgrade or after changing the QIAcuity Software Suite connection, the login screen may briefly appear. Ignore the login screen and wait for the QIAcuity instrument to shut down and restart automatically.
If you are unsure how to proceed or require technical assistance, contact QIAGEN Technical Service.
Version 11
The Volume Precision Factor (VPF) offers a unique feature to secure precision of concentration results obtained from a QIAcuity dPCR run.
In general, Nanoplates provide partitions of fixed sizes that enable a very precise way of sample concentration calculation. Potential variation of partition sizes in Nanoplate batches, caused by different microstructure molding forms, can be addressed by applying the batch specific VPF. Furthermore, the VPF includes well-specific volume information and therefore further increases precision of concentration calculation in each well of the Nanoplates.
"Version 2.1
Version 3.0
Version 3.1
Version 2.1.8
Version 2.2
Version 2.5
Version 3.1.3
Version 3.2
Version 2.1
Version 2.1.8
Version 2.2
Version 2.5.0.0
Version 2.5.0.1
Version 3.2
Version 3.0
Version 3.1
Version 3.1.1
This is not needed. The QIAcuity is equipped with a flexible power supply technology and operates within a range of 100–240V AC, 50/60 Hz, 1500 VA (max).
The instrument software GUI shows error codes including a description and information how to resolve the error. The instrument touchscreen shows an alarm icon in the upper right corner that turns red in case of an instrument failure. Accessing the System Status in the Tool tab allows users to clear errors. Rebooting of the instrument is required to complete the removal of the error. Please do not skip this step. You may always contact QIAGEN Technical Services in case of any question.
The user manual contains instructions on how to perform a regular cleaning and decontamination, and how to replace air filters on the QIAcuity instruments. A regular maintenance reduces the dust in the instrument and therefore minimizes the presence of dust particles on the nanoplate, which might interfere with the plate analysis.
If you had run a nanoplate for which the installed VPF misses the specific factor, the software will notify you. If you then analyze without the specific VPF, the impact depends on the variation of the partition volume of the new Nanoplate batch compared to the latest. Typically this variation is ±6–7% (approx. 5% CV over the entire plate). The analysis may be repeated after updating the VPF file. After installing the latest VPF and re-analysis of the run, a copy of the plate is generated in the QIAcuity Software Suite including the new results.
Yes, the report includes a notification if the matching VPF was missing and, therefore, not applied to the analysis. If the matching VPF was applied there is no notification on the report.
If you had analyzed your nanoplates without VFP, the impact depends on the variation of the partition volume of the new nanoplate batch compared to the latest. The VPF reduces the CV from approximately 5% to 2%. We recommend to reanalyze results in case the data originated from different wells (e.g., copy number variations or gene expression data sets for which the reference sample was measured in a different well). Results obtained across different plates should also be r-analyzed. A reanalysis is not required for assay data that were analyzed within the same well (e.g., mutation rate determination using two channels within the same well).
A standard PCR plate is required to set up dPCR reaction before transferring it to the nanoplate to ensure a proper mixing of the reaction mix before partitioning.
QIAGEN master mixes are optimized for nanoplate microfluidics and are recommended to be used with our dPCR system. They also include an optimized reference dye required for proper analysis.
All DNA samples used in reaction mixes should show similar quality and quantity, which can easily be assessed using UV spectrophotometry. DNA samples with an average length of ≥20 kb (e.g., genomic DNA purified via spin column with silica membrane) should be fragmented by restriction digestion before partitioning. Enzymatic fragmentation of larger DNA ensures an even distribution of template throughout the QIAcuity Nanoplate, which in turn leads to an accurate and precise quantification.
The QIAcuity Probe PCR Kit should be stored immediately upon receipt at –30 to –15°C in a constant-temperature freezer and protected from light. The QIAcuity Probe PCR master mix can also be stored protected from light at 2–8°C. Components are stable for 12 months, unless otherwise indicated on the label.
The QIAcuity EG PCR Kit should be stored immediately upon receipt at –30 to –15°C in a constant-temperature freezer and protected from light. The QIAcuity EG PCR master mix can also be stored protected from light at 2–8°C. Components are stable for 6 months, unless otherwise indicated on the label.
The QIAcuity Nanoplates does not have expiry date and are stable for at least 1 year when stored at RT.
The plate is designed for a single use run. For example, even if only 30 samples are loaded into the 96-well plate, a whole plate will be sealed by the roller. It can't be unsealed and used for another run. The QIAcuity Software won’t allow to set up a separate experiment for the same nanoplate to avoid that previously processed plates being not partitioned a second time.
An essential temperature gradient functionality was introduced with software version 2.5. When updating older software versions to 2.5, each QIAcuity instrument will offer the temperature gradient and may be used to find the best cycling temperature for new dPCR assays. When running a QIAcuity Four or a QIAcuity Eight, all plates may have their own temperature profile, including the option for a temperature gradient.
The VPF provides a set of well-specific and molding form-specific factors used to specify the exact reaction volume of a nanoplate, thus increasing the concentration calculation of each well.
In general, nanoplates provide partitions of fixed sizes that enable a very precise way of sample concentration calculation. If a new molding form is used for nanoplate manufacturing, potential variation of partition sizes can be addressed by applying the molding form-specific VPF. Thus, each time a new molding form is used, a new VPF is created and made available. Currently, the VPF is updated once every 3–6 months.
In dPCR we measure the absolute concentration of targets at endpoint reaction. Concentrations of unknowns can be determined based on dPCR results observed (number of negatives, number of positives, and partition volume analyzed).