For qPCR-enabled quantification of NGS libraries
  • Ready-to-use, predispensed, sequentially diluted DNA standard (array format)
  • Automatic calculation of library concentration
  • Simple protocol, high sensitivity, and wide dynamic range
  • Compatibility with Illumina and Ion Torrent/Proton NGS platforms
  • Compatibility with most qPCR instruments
The QIAseq Library Quant System provides a simple, out-of-the-box solution to quantify NGS libraries, enabling consistent results with every NGS run. The QIAseq Library Quant System uses real-time PCR to specifically quantify DNA molecules with sequencing adaptors at both ends, ensuring optimal cluster density or template-to-bead ratio.

Please note: GeneRead Library Quant Array (product number 180611) and GeneRead Library Quant Kit (product number 180612) will be phased out by the end of 2016. Please use QIAseq Library Quant Assay Kit (product number 333314) instead.
Product Product no. Cat. no. List price:
 
 
show details
    varies
Can't order online?
To place an order via phone, email or for requesting a quote, please provide the product’s name, number and catalog number.
Available Products
6
Product Product no. Cat. no. List price:
qPCR arrays (96-well format) for quantifying Illumina libraries
show details
333304 QSIL-003 varies
qPCR arrays (384-well format) for quantifying Illumina libraries
show details
333304 QSIL-3003 varies
qPCR arrays (96-well format) for quantifying Ion Torrent libraries
show details
333304 QSIT-003 varies
qPCR arrays (384-well format) for quantifying Ion Torrent libraries
show details
333304 QSIT-3003 varies
qPCR assays for quantifying Illumina libraries
show details
333314 QSTF-ILZ varies
qPCR assays for quantifying Ion Torrent libraries
show details
333314 QSTF-ITZ varies
Configure
Product Product no. Cat. no. List price:
 
 
show details
    varies
Can't order online?
To place an order via phone, email or for requesting a quote, please provide the product’s name, number and catalog number.
The QIAseq Library Quant System is intended for molecular biology applications. This product is not intended for the diagnosis, prevention, or treatment of a disease.
  • Main Image Navi
QIAseq Library Quant Array workflow|The QIAseq Library Quant System enables quantification of libraries with concentrations below the detection limit of conventional methods|Principle of the QIAseq Library Quant System|
Each sample DNA library is combined with QIAseq qPCR SYBR® Green Mastermix, aliquoted in technical triplicate across the QIAseq Library Quant Array, and analyzed with qPCR. Raw CT values are copied into the data analysis Excel template, and the software automatically calculates the library concentration or dilution factor.|The QIAseq Library Quant Array's high sensitivity and broad dynamic range enable the quantification of both the NGS-L1 and NGS-L2 libraries [A]. By contrast, Agilent's High Sensitivity DNA Kit (for use with the Agilent 2100 BioAnalyzer) quantified only the NGS-L1 library; with this kit, the NGS-L2 concentration was too low for quantification [B].|The serial dilutions of the DNA standard (5 sequential 10-fold dilutions) generate a standard curve. The sample library should fall within the standard curve.|
Performance

The sensitivity and dynamic range of the QIAseq Library Quant System were compared against Agilent's High Sensitivity DNA Kit, using two NGS libraries of differing concentrations. The first library was quantifiable by both systems, but the low concentration of the second library was below the detection limit of Agilent's 2100 BioAnalyzer. By contrast, the QIAseq Library Quant Array was able to quantify both libraries (see figure QIAseq Library Quant System enables quantification of libraries with concentrations below the detection limit of conventional methods).

Principle
Accurate quantification of library molecules is essential for the efficient use of NGS platforms; however, current spectrophotometric methods only measure total nucleic acid concentrations. The QIAseq Library Quant System, by contrast, uses real-time PCR to quantify only DNA molecules with adaptors at both ends, which are the only amplifiable molecules during emulsion PCR (Ion Torrent platform) or bridge PCR (Illumina platform), and therefore provides highly accurate quantification of amplifiable library molecules. The high sensitivity of real-time PCR allows quantification of libraries at very low concentrations, even below the detection threshold of conventional spectrophotometric methods.

The QIAseq Library Quant System is available in both a tube and an array format, and is optimized with QIAseq qPCR SYBR® Green Mastermixes to provide superior sensitivity and a wide dynamic range. Both formats provide a DNA standard specific to the Illumina or Ion Torrent platform. The array format provides this standard in five predispensed, sequential 10-fold dilutions mixed with a PCR primer assay in triplicate, ensuring that your sample library will fall within the detection range of the array (see figure Principle of QIAseq Library Quant System).
Procedure

The array format workflow (see figure QIAseq Library Quant Array workflow) begins with two tenfold dilutions of the sample library, to ensure that its concentration falls within the range of the serially diluted standards. The samples are mixed with QIAseq qPCR SYBR Green Mastermix and aliquoted in technical triplicate across the array plate. PCR is performed, and raw CT values are exported to the provided data analysis Excel file for automatic calculation of library concentration (Illumina platform) or template dilution factor (Ion Torrent/Proton platform).

The tube format workflow is similar to the array format workflow, with a few small differences. The procedure begins with preparation of five sequential tenfold dilutions of DNA Standard and two tenfold dilutions of the sample library. This ensures that the concentration of the library will fall within the range of the standard dilutions. Next, the diluted DNA standards and sample libraries are mixed with the provided PCR assay and the appropriate QIAseq qPCR SYBR Green Mastermix. PCR is performed, and CT values are exported to the provided data analysis Excel file for automatic calculation of library concentration (Illumina platform) or template dilution factor (Ion Torrent/Proton platform).

Applications
The QIAseq Library Quant Array and QIAseq Library Quant Kit provide rapid, accurate measurement of sample library concentration prior to sequencing with the Illumina or Ion Torrent/Proton NGS platforms.

You are not authorized to download the resource

Brochures & Guides
2
Analysis Software
8
New version – Excel-based data analysis template for use with GeneRead Library Quant Kit (assay format) or GeneRead Library Quant Array for 384-well plates for Illumina libraries
Show details
New version – Excel-based data analysis template for use with GeneRead Library Quant Kit (assay format) or GeneRead Library Quant Array for 384-well plates for Ion Torrent libraries
Show details
New version – Excel-based data analysis template for use with GeneRead Library Quant Kit (assay format) or GeneRead Library Quant Array for 96-well plates for Illumina libraries
Show details
New version – Excel-based data analysis template for use with GeneRead Library Quant Kit (assay format) or GeneRead Library Quant Array for 96-well plates for Ion Torrent libraries
Show details
New version – Excel-based data analysis template for use with GeneRead Library Quant Kit (assay format) or GeneRead Library Quant Array for Rotor-Disc 100 rings for Illumina libraries
Show details
New version – Excel-based data analysis template for use with GeneRead Library Quant Kit (assay format) or GeneRead Library Quant Array for Rotor-Disc 100 rings for Ion Torrent libraries
Show details
New version – Excel-based data analysis template for use with GeneRead Library Quant Kit (assay format) for 72-well Rotor rings for Illumina libraries
Show details
New version – Excel-based data analysis template for use with GeneRead Library Quant Kit (assay format) for 72-well Rotor rings for Ion Torrent libraries
Show details
Kit Handbooks
4
New version – For reliable quantification of Ion Torrent or Illumina® libraries using real-time PCR
Show details

Show details
New version – For reliable quantification of Ion Torrent or Illumina® libraries using real-time PCR (assay format)
Show details

Show details