therascreen EGFR Plus RGQ PCR Kit

For detection and identification of 42 mutations in exons 18, 19, 20 and 21 of the EGFR gene

S_1212_6_MDx_CG_theraEGFRPlusRGQPCR_CEIVD

✓ 24/7 automatic processing of online orders

✓ Knowledgeable and professional Product & Technical Support

✓ Fast and reliable (re)-ordering

therascreen EGFR Plus RGQ PCR Kit (24)

Cat. No. / ID:  874611

For 24 reactions: T790M & L861Q Mix, Insertions & G719X Mix, L858R & C797S Mix, Deletions & S768I Mix, PCR Master Mix, EGFR Positive Control, RNase/DNase-free Water
Copy order details
ProductKitInstrumentSoftware
therascreen EGFR Plus RGQ PCR Kit (24)
QIAamp DSP Circulating NA Kit
QIAsymphony DSP DNA Mini Kit
QIAsymphony DSP Circulating DNA Kit (192)
Rotor-Gene Q MDx HRM
Rotor-Gene Q MDx HRM Platform
Rotor-Gene AssayManager
The therascreen EGFR Plus RGQ PCR Kit is intended for in vitro diagnostic use.

✓ 24/7 automatic processing of online orders

✓ Knowledgeable and professional Product & Technical Support

✓ Fast and reliable (re)-ordering

Features

  • Detection of TKI resistance biomarkers, including T790M and C797S
  • Run FFPE and liquid biopsy samples in the same PCR run
  • Reliable, sensitive and specific detection of clinically relevant EGFR mutations
  • Automated sample preparation option with QIAsymphony SP
  • Automated analysis and next-day result reporting with Rotor-Gene Assay Manager software

Product Details

The therascreen EGFR Plus RGQ PCR Kit is an in vitro diagnostic real-time PCR test intended for the qualitative detection and identification of 42 mutations in exons 18, 19, 20 and 21 of the epidermal growth factor receptor (EGFR) gene in DNA samples extracted from plasma or formalin-fixed paraffin-embedded (FFPE) tumor tissue taken from non-small cell lung cancer (NSCLC) patients.

Furthermore, the kit also indicated for the semi-quantitative measurement of mutations in exons 18, 20 and 21 of the EGFR gene in DNA samples extracted from human plasma as an aid in the clinical management of NSCLC patients.

The test is intended to be used as an aid in selecting patients with NSCLC for therapy with an EGFR tyrosine kinase inhibitor (TKI).

Performance

When compared to the analytical reference method, there was a high level of concordance between therascreen EGFR Plus RGQ PCR Kit and the analytical accuracy method(s). The reference and discrepancy resolution methods used were: PNA qPCR, Sanger bi-directional sequencing; next-generation sequencing, therascreen EGFR RGQ PCR Kit V2 (cat. no. 874111) and therascreen EGFR Plasma RGQ PCR Kit (cat. no. 870311).

Results were analyzed to assess the positive percent agreement (PPA), negative percent agreement (NPA) and overall percent agreement (OPA) regarding EGFR mutation status (mutant; MT or wild-type; WT) and EGFR target (mutation identification) for FFPE and plasma samples between therascreen EGFR Plus RGQ PCR Kit and respective reference method and following discrepancy resolution method.

FFPE samples

In the study 170 FFPE samples were tested, of which 48 gave valid interpretable results (148 sample status and 155 target status).

When the results of the therascreen EGFR Plus RGQ PCR Kit were compared to the results of the respective reference method, four EGFR sample status (MT or WT) showed discordance. Following discrepancy resolution method analysis, the number of discordant samples statuses (MT or WT) decreased to one discrepant, false-negative sample status. The PPA, NPA and OPA with the corresponding two-sided 95% confidence intervals (CI) are summarized in Table 1 and Table 2.

Table 1. Analysis of agreement of overall mutation status per sample: therascreen EGFR Plus RGQ PCR Kit and reference method comparison for FFPE samples

    Lower limit 95% CI Upper limit 95% CI
OPA 97.30% 93.22% 99.26%
PPA (sensitivity) 93.65% 84.53% 98.24%
NPA (specificity) 100.00% 95.75% 100.00%

Table 2. Analysis of agreement of overall mutation status per sample after discordant investigation for FFPE samples

    Lower limit 95% CI Upper limit 95% CI
OPA 99.32% 96.29% 99.98%
PPA (sensitivity) 98.33% 91.06% 99.96%
NPA (specificity) 100.00% 95.89% 100.00%

Plasma samples

In the study, 106 plasma samples were tested and 106 gave valid interpretable results (106 sample status and 121 target status).

When the results of therascreen EGFR Plus RGQ PCR Kit were compared to the results of the respective reference method, nine EGFR sample status (MT or WT) showed discordance. Following discrepancy resolution method analysis, the number of discordant samples status (MT or WT) decreased to three discrepant, one false-negative, and two false-positive sample status. The PPA, NPA, and OPA with the corresponding two-sided 95% confidence intervals (CI) are summarized in Table 3 and Table 4.

Table 3. Analysis of agreement of overall mutation status per sample: therascreen EGFR Plus RGQ PCR Kit and reference method comparison for plasma samples

    Lower limit 95% CI Upper limit 95% CI
OPA 91.51% 84.49% 96.04%
PPA (sensitivity) 87.27% 75.52% 94.73%
NPA (specificity) 96.08% 86.54% 99.52%

Table 4. Analysis of agreement of overall mutation status per sample after discordant investigation for plasma samples

    Lower limit 95% CI Upper limit 95% CI
OPA 97.17% 91.95% 99.41%
PPA (sensitivity) 97.96% 89.15% 99.95%
NPA (specificity) 96.49% 89.89% 99.57%

Principle

The therascreen EGFR Plus RGQ PCR Kit comprises four triplex assays, each containing all the oligonucleotides (primers, probes and oligonucleotide clamp, where applicable) necessary to amplify and detect the targeted EGFR mutations. In each assay, two target mutations and one internal amplification control are assayed to determine the presence or absence of mutant DNA and to identify reaction failures due to suboptimal DNA input, or the presence of inhibitory substances in the sample matrix.

Allele-specific technology allows accurate and highly reproducible detection of mutations. DNA is selectively amplified using ARMS primers, probes and PCR clamps, with sensitive signal detection using the Rotor-Gene Q MDx 5plex HRM instrument. Result reporting is fully automated using Rotor-Gene AssayManager v2.1 software. If both the positive and no template controls are valid and the sample internal controls are valid, the EGFR mutation status will be displayed in the software.

Procedure

Flexibility is key to the therascreen EGFR Plus RGQ PCR System – with a choice of sample types and DNA extraction methods before real-time PCR.

DNA extraction from FFPE tissue or plasma samples can be performed manually or automated on the QIAsymphony SP, for walkaway sample processing. DNA is extracted from FFPE tissue samples manually using the QIAamp DSP DNA FFPE Tissue Kit, while automated processing uses the QIAsymphony DSP DNA Mini Kit. Plasma samples are processed manually using the QIAamp DSP Circulating Nucleic Acid Kit, while the QIAsymphony DSP Circulating DNA Kit offers automated DNA purification.

Following DNA extraction and quantification, sensitive real-time PCR is performed on the Rotor-Gene Q MDx 5plex HRM instrument. Automated data analysis displays qualitative results in Rotor-Gene AssayManager software, informing the system operator if one or more of the 42 mutations detected by the kit are present. The assay can be completed in ~8 hours, providing next-day results and informing earlier treatment decisions.

Applications

The therascreen EGFR Plus RGQ PCR Kit enables qualitative detection of 42 mutations in the EGFR gene for in vitro diagnostic use. It is an IVD assay to support treatment decisions when selecting NSCLC patients for therapy with an EGFR tyrosine kinase inhibitor (TKI).

Supporting data and figures

Resources

Instrument User Manuals (6)
For creation of Rotor-Gene AssayManager assay profiles (only available for the User Defined Test [UDT] mode)
For installation and setup of Rotor-Gene AssayManager
For use of Rotor-Gene AssayManager in User Defined Test (UDT) mode in combination with the UDT Basic Plug-in
For use with Rotor-Gene Q Software version 2.3.4
Performance Data (1)
Application/Protocol Documents for IVD Use (7)
For use with software version 4.0 or higher
For use with software version 4.0 or higher
For use with software version 4.0 or higher
For use with software version 4.0 or higher
For use with software version 4.0 or higher
For use with software version 4.0 or higher
For use with software version 4.0 or higher
Kit Handbooks (3)
For the Directive 98/79/EC (IVDD) compliant kit (kit version 1)
For verification of thermal accuracy of Rotor-Gene real-time cyclers
Operating Software (1)
For use on the Rotor-Gene Q. Rotor-Gene Q software 2.3.5 is compatible with Windows 7 and Windows 10 operating systems
Software Release Notes (1)
Technical Information (2)
Labware Documents (1)
For use with software version 5.0 or higher
Certificates of Analysis (1)

FAQ

Which-reporter-dyes-can-be-combined-for-use-in-multiplex-PCR-on-the-Rotor-Gene-Q-Cycler?
Please refer to section 'Guidelines for effective multiplex assays' under "Important Notes" in the Rotor-Gene Multiplex PCR Handbook for suitable combinations of reporter dyes, or visit our Multiplex real-time PCR Resource site for additional information.
FAQ ID -9028
What reaction volume is suitable for use in the Rotor-Gene Q?

Reaction volumes suitable for use on the Rotor-Gene Q are:

  • Rotor-Disc 100: 30 µl x 100-wells, 10-25 µl reaction volume
  • Rotor-Disc 72: 0.1 ml x 72-wells, 15-25 µl reaction volume
  • Strip Tubes 0.1 ml: 0.1 ml x 72-wells, 10-30 µl reaction volume, strips of 4 tubes and caps
  • PCR Tubes 0.2 ml: 0.2 ml x 36-wells, 15-50 µl reaction volume, individual tubes with caps
FAQ ID -9030
What sample types can be processed using the tissue protocols and the QIAsymphony DSP DNA Mini Kit?
Tissue and FFPE tissue can be processed using the tissue protocols and the QIAsymphony DSP DNA Mini Kit on the QIAsymphony SP.
FAQ ID -2925
How much starting material can be used with the QIAsymphony DSP DNA Mini Kit on the QIAsymphony SP?

Tissue: If no information about the expected yield is available, we recommend starting with 25 mg sample material. Depending on the yield obtained, the sample size can be increased in subsequent preparations to a maximum of 50 mg.

FFPE: Up to 4 sections, each with a thickness of up to 10 µm, or 8 sections with a thickness of up to 5 µm and a surface area of up to 250 mm2, can be combined in one preparation.

FAQ ID -2927
Why is no fluorescence signal detected in my run?

Please make data are collected in the appropriate fluorescent channel. Also check the gain is optimized.

If the issue persists, please send the original run file with extension .rex to QIAGEN Technical Service for further assistance.

FAQ ID -9023
What sample volumes can be used with the tissue HC and LC protocols on the QIAsymphony SP?
After pretreatment, 220 µl of the lysates must be transferred to the QIAsymphony SP to ensure that 200 µl of sample is processed.
FAQ ID -2992
What should I do if the Rotor-Disc OTV run does not pass?

Please send the original OTV run file to QIAGEN Technical Service for further assistance.

FAQ ID -9022
What are the recommended lysis times for tissue samples on the QIAsymphony SP?
Lysis time varies depending on the tissue type processed. For recommended lysis times refer to the tissue protocol sheets. If lysis is incomplete after recommended lysis time, as indicated by the presence of insoluble material or highly viscous lysates, lysis time can be prolonged or insoluble material can be removed by centrifugation. Overnight lysis is possible and does not affect the preparation.
FAQ ID -2993
What kind of file is required for hardware-related trouble-shooting?
For hardware related issues, please send the support package to QIAGEN Technical Service. Within the Rotor-gene Q software, click Help and select Send Support Email. In the new window, select the file that relates to the issue and email it to QIAGEN Technical Service.
FAQ ID - 9024
Is regular calibration needed with the Rotor-gene instrument?
QIAGEN recommends the annual inspection service on Rotor-gene instruments, during which all application-critical modules of the Rotor-gene are inspected and tested and an OTV check is conducted. Performed tests and test results are documented in a GMP/GLP-compliant Report. In addition, the end users can perform the temperature calibration in the lab as needed using the Rotor-Disc OTV kit.

Note: The Rotor-Disc OTV kit requires the Rotor-Disc 72 Rotor and Rotor-Disc 72 locking ring.
FAQ ID -9025
What can be used as an alternative to the A260 measurement for quantification of small amounts of RNA and DNA?

Small amounts of RNA and DNA may be difficult to measure spectrophotometrically. Fluorometric measurements, or quantitative RT-PCR and PCR are more sensitive and accurate methods to quantify low amounts of RNA or DNA.

Fluorometric measurements are carried out using nucleic acid binding dyes, such as RiboGreen® RNA Quantitation Reagent for RNA, and PicoGreen® DNA Quantitation Reagent for DNA (Molecular Probes, Inc.).

FAQ ID -728
What sample types should be processed with the low content (LC) and high content (HC) protocols for DNA extraction on the QIAsymphony SP?
Tissues will give increased DNA yields when processed with the high content protocol, but the low content protocol in combination with a small elution volume (50µl) may be used if high DNA concentration is required. For FFPE tissue we recommend using the low content protocol.
FAQ ID -2989
Will mitochondrial DNA also be isolated using the DNA tissue protocols and QIAsymphony DSP DNA Mini Kit on the QIAsymphony SP?
Yes. The DNA tissue protocols on the QIAsymphony SP purify genomic and mitochondrial DNA.
FAQ ID -2991
Must I fill blank positions with empty tubes when running sample numbers lower than the rotor capacity of the Rotor Gene Q?
Yes, all empty positions in the rotor of the Rotor-Gene Q have to be filled with empty tubes. This guarantees optimal temperature repartition in the Rotor-Gene Q chamber.
FAQ ID -9029