QuantiNova LNA Probe PCR Flexible Panels

For in-depth pathway- or disease-specific gene expression analysis using LNA-enhanced, probe-based PCR

Products

QuantiNova LNA Probe PCR Flexible Panels are intended for molecular biology applications. These products are not intended for the diagnosis, prevention, or treatment of a disease.
Image
QuantiNova LNA Probe PCR Flexible Panels

Cat. No. / ID:  249965

Ready-to-use plate containing a customized selection of focus panel assays in 96- or 384-well format for any cycler. Minimum order is 4-12 plates, depending on your configuration; price discounted when ordering 6 or more copies of the same plate: 6-11 plates 15% off, 12-23 plates 30% off, >24 plates 50% off.
Copy order details

Features

  • Build your own panel with any combination of assays from our cataloged Focus Panel assays
  • Easy online ordering through the intuitive custom builder tool
  • Exceptional sensitivity and specificity using short, LNA-enhanced primers and FAM-labeled hydrolysis probes
  • Stability for room-temperature setup allowing automation
  • Robust and reproducible results in less than 2 hours using the QuantiNova Probe PCR Kit

Product Details

QuantiNova LNA Probe PCR Flexible Panels enable quick and reliable gene expression profiling using hydrolysis probe-based qPCR. Simply tailor one of our existing Focus Panels to your requirements, or build a new panel containing assays from our cataloged Focus Panels. LNA enhancement enables us to design shorter primers with optimal Tm, allowing flexible positioning on the target for optimal sequence discrimination. Thorough design validation ensures top performance and robust detection. Optimized using QuantiNova chemistry, the simple workflow can be completed in under 2 hours and is robust enough to support room-temperature setup, automation and delayed run. We also offer Custom Panels, which are fully customizable with the predesigned and/or custom assays of your choice.

Need a quote for your research project or would you like to discuss your project with our specialist team? Just contact us!

Performance

Expert LNA enhancement for top qPCR performance

The assays in the QuantiNova LNA Probe PCR Flexible Panels have been developed using stringent design criteria and lab-validated algorithms. Twenty years of LNA design experience has enabled us to optimize our sophisticated LNA design algorithm, which incorporates over 50 different parameters to guarantee the most optimal assay for successful target detection. Each primer–probe set delivers the highest specificity and efficiency for the most reliable and accurate results. LNA enhancement enable Tm normalization across the panel, giving the primers and probes higher binding affinity, dramatically increasing assay sensitivity and specificity.

The increased sensitivity ensures excellent amplification efficiencies down to 1 RNA molecule, making it easier for you to detect low-abundance targets such as lncRNAs from less starting material (see figure  QuantiNova LNA Probe PCR Assays provide accurate, sensitive and linear quantification of targets over a wide dynamic range and figure  QuantiNova LNA Probe PCR Assays enable both high-expression and low-expression detection of mRNA). Increased specificity from the clever placement of LNA gives you a high signal-to-noise ratio, allowing discrimination of sequences that differ by only a single nucleotide and eliminating non-specific amplification and primer-dimer formation.

The high binding affinity of LNA bases increases the flexibility of primer and probe placement on the transcript, so we are able to use intelligent positioning to design assays for otherwise difficult-to-analyze targets. This gives you robust and reliable quantification, even for AU-rich targets, low-abundance transcripts, targets with high secondary structure and highly complex samples.

See figures

Principle

Robust and high-performance hydrolysis probe-based qPCR

QuantiNova LNA Probe PCR Flexible Panels use FAM-labeled hydrolysis probe-based detection, which is highly sensitive and robust, because only the desired PCR product is detected. Probe-based detection still requires high PCR specificity to prevent amplification artifacts such as non-specific PCR products and primer–dimers that can compete for reaction components and compromise performance. However, we’ve already optimized the QuantiNova LNA Probe PCR system for you to eliminate non-specific amplification and give you accurate and sensitive detection every time.

Choose from assays on our cataloged Focus Panels

QuantiNova LNA Probe PCR Focus Panels include the assays needed for a thoroughly researched panel of relevant pathway- or disease-focused genes. The predesigned assays have been designed using our proprietary algorithm to provide the most sensitive, accurate and effective analysis. Most of the assays are intron-spanning when possible and detect only RNA. Assays that do not span an intron are designated as such, and if there is one exon in the target, unwanted signals can be easily eliminated using the QuantiNova Reverse Transcription Kit with the integrated gDNA removal step.

Flexible Panel vs. Custom Panel

QuantiNova LNA Probe PCR Flexible Panels are a semi-customizable product and are available in 96-well plate, 384-well plate and 100-well disc formats, with up to 96 different assays on each plate. Flexible Panels can only contain assays from our available Focus Panels. Our convenient custom builder allows you to simply load the plate content of an existing Focus Panel and swap out the assays to meet your requirements. Reference gene assays and controls from our Focus Panels can also be added.

QuantiNova LNA Probe PCR Custom Panels are a fully customizable product and are also available in 96-well plate, 384-well plate and 100-well disc formats, with all of our different plate layouts available. The custom builder allows you to upload your own list of targets and add any predesigned or custom assays of your choice. Any reference genes and control assays and controls can also be added.

 
Available plate layouts, minimum order quantity and multiple plate discount
Plate format Number of different assays per plate Configuration Minimum order
96-well or 100-well disc 8 assays 8 assays x 12 samples 4 plates
12 assays 12 assays x 8 samples 4 plates
16 assays 16 assays x 6 samples 4 plates
24 assays 24 assays x 4 samples 4 plates
32 assays 32 assays x 3 samples 4 plates
48 assays 48 assays x 2 samples 4 plates
96 assays 96 assays x 1 sample 6 plates
384-well 8 assays 8 assays x 48 samples 6 plates
12 assays 12 assays x 32 samples 6 plates
16 assays 16 assays x 24 samples 6 plates
24 assays 24 assays x 16 samples 6 plates
32 assays 32 assays x 12 samples 6 plates
48 assays (horizontal) 48 assays x 8 samples 6 plates
48 assays (normal vertical) 48 assays x 8 samples 6 plates
64 assays 64 assays x 6 samples 6 plates
96 assays 96 assays x 4 samples 6 plates
128 assays 128 assays x 3 samples not applicable
192 assays 192 assays x 2 samples not applicable
384 assays 384 assays x 1 sample not applicable

 

Plate quantity ordered Discount (%)
1–5 0
6–11 15
12–23 30
24+ 50
Complimentary data analysis

The complimentary, web-based data analysis tool in the GeneGlobe Data Analysis Center includes a user-friendly wizard to guide you step-by-step through the normalization and analysis of your data and generates publication-ready results figures.

Procedure

Choose one- or two-step qRT-PCR

QuantiNova LNA Probe PCR Flexible Panels have been optimized using the time-tested and high-performance QuantiNova chemistry. Best results are obtained when reverse transcription is performed with the QuantiNova Reverse Transcription Kit. The resulting cDNA is then quantified by qPCR using the master mixes of the QuantiNova Probe PCR Kit combined with the assays on your panel.

For one-step qRT-PCR, we recommend using the QuantiNova Probe RT-PCR Kit, which offers quick reaction setup without need for optimization of reaction conditions. Simply combine RNA template with the ready-to-use RT-PCR master mix and the assays on your panel and start the reaction.

Fast and easy workflow

The fast and easy workflow can be completed in under 2 hours with minimal hands-on time and can be automated to save even more time and labor. The simple protocol has been tested for compatibility on all major brand qPCR cyclers (see figure QuantiNova LNA Probe PCR Assays deliver consistent performance across all thermal cycler instruments). Furthermore, the cDNA generated in the RT step can be used across the entire QuantiNova LNA Probe PCR System, allowing seamless transition from assays to panels depending on your research needs, saving you time and sample.

What you need to get started with the QuantiNova LNA Probe PCR system

Reverse transcription: QuantiNova Reverse Transcription Kit

qPCR mastermix: QuantiNova Probe PCR Kit

One-Step qRT-PCR (optional): QuantiNova Probe RT-PCR Kit

Assays or panels:

  • QuantiNova LNA Probe PCR Assays
  • QuantiNova LNA Probe PCR Reference Assays
  • QuantiNova LNA Probe PCR Custom Assays
  • QuantiNova LNA Probe PCR Focus Panels
  • QuantiNova LNA Probe PCR lncRNA Focus Panels
  • QuantiNova LNA Probe PCR Custom Panels
  • QuantiNova LNA Probe PCR Flexible Panels

Applications

QuantiNova LNA Probe PCR Flexible Panels are highly suited for applications including:

  • mRNA and lncRNA expression analysis, profiling and quantification
  • Validation of RNA-seq gene expression data
  • Gene expression profiling
  • Signal and pathway analysis
  • Confirming gene expression knockdown by LNA GapmeRs or siRNAs
  • Biomarker development, including screening, identification and validation of disease-associated biomarkers
  • Monitoring phenotypic changes related to gene expression

Supporting data and figures

Resources

Kit Handbooks (1)
QuantiNova LNA Probe PCR Handbook
Quick-Start Protocols (1)
Certificates of Analysis (1)