QIAamp Circulating Nucleic Acid Kit
For isolation of free-circulating DNA and RNA from human plasma or serum
- Concentration of nucleic acids, with high input and low elution volumes
- Efficient recovery of fragmented DNA and RNA
- No organic extraction or ethanol precipitation
- Removal of contaminants and inhibitors
The QIAamp Circulating Nucleic Acid Kit greatly simplifies concentration and purification of free-circulating DNA and RNA from plasma or serum. The kit can be automated on the QIAcube Connect.
ja-JP
|
製品名
|
Cat. no.
|
List price:
|
|
|
QIAamp Circulating Nucleic Acid Kit (50)
For 50 preps: QIAamp Mini Columns, Tube Extenders (20 ml), QIAGEN Proteinase K, Carrier RNA, Buffers, VacConnectors, and Collection Tubes (1.5 ml and 2 ml)
|
55114
|
|
|
|
Carrier RNA(poly A) 12x1350µg-15-25°C,KG
Carrier RNA(poly A) 12x1350µg-15-25°C,KG
|
1017647
|
|
|
QIAamp Circulating Nucleic Acid Kit は分子生物学実験用です。疾病の診断、治療または予防の目的には使用することはできません。
遊離DNAの再現性の高い回収|改良されたDNAフラグメントの回収|遊離miRNA の効率的な精製|メチル化DNAの効率的な回収|
同量のDNAフラグメント(200 bpと1000 bp)を血漿24サンプルに添加した。DNAを5 ml の血漿からQIAamp Circulating Nucleic Acid Kit で精製し、80 μl で溶出した。QuantiTect Multiplex PCR Kit を用いて、各DNAフラグメントに特異的な66 bpターゲットのduplexリアルタイムPCRを行なった。|遊離DNA を5 ml の血漿からQIAamp Circulating Nucleic Acid Kit で、1 ml の血漿からQIAamp MinElute Virus Vacuum Kit で精製し、100 μl で溶出した。QuantiTect Multiplex PCR Kit を用いて、18S rRNA遺伝子のアンプリコン66 bpと500 bpのduplexリアルタイムPCRを行なった。500 bp と66 bp のアンプリコンの増幅差はDNAのフラグメント化を示し、短い66 bp ターゲットと比較してインタクトな500 bp ターゲット配列が少なかった(この差は使用したサンプル量の5倍差より大きいことに注意)。|標準プロトコールで5 ml、miRNA 専用プロトコールで 3 ml のプール血漿から、QIAamp Circulating Nucleic Acid Kit で遊離RNA を精製し、50 μl で溶出した。標準プロトコール
をmiRNA 専用プロトコールと比較した。 miRNA 30bの収量はTaqMan microRNA Assay(Applied Biosystems)で、miRNA 16の収量はHuman miScript Assay(QIAGEN)でそれぞれ定量した。miRNA プロトコールでの低いCT 値は両miRNA の収量が高いことを示唆している。|メチル化DNAと非標的poly-A RNA(キャリア)を添加した血漿4 ml からQIAamp Circulating Nucleic Acid Kit を用いて精製し、45 μlで溶出した。EpiTect Bisulfite Kit (QIAGEN)を用いてBisulfite変換し、リアルタイムMSP アッセイとQuantiTect Multiplex PCR Kit の試薬を用いたMSP(methylation-specific PCR)をABI PRISM 7900HT Sequence Detection Systemで行なった。2つの完全にメチル化された遺伝子座データを解析した。|
パフォーマンス
Analysis of tumor-specific extracellular DNA fragments and mRNAs in the blood can enable specific detection of tumor types from a simple blood sample. These circulating nucleic acids are present in serum or plasma usually as short fragments, <1000 bp (DNA) or <1000 nt (RNA). In addition, miRNAs, as small as 21 nt, have the potential to provide biomarkers for certain cancers and disease states.
The QIAamp Circulating Nucleic Acid Kit enables efficient purification of these circulating nucleic acids from human plasma or serum and other cell-free body fluids. Efficient purification with reproducible yields provides a representative population of the circulating nucleic acids in blood (see figure "Reproducible recovery of circulating DNA"). Tube extenders and vacuum processing on the QIAvac 24 Plus enable starting sample volumes of up to 5 ml, and flexible elution volumes between 20 μl and 150 μl allow concentration of nucleic acid species that are present in low concentrations. The kit provides advanced technology of selective binding to a silica-based membrane for improved recovery of fragmented nucleic acids (see figure "Improved recovery of fragmented DNA").
Purification of circulating RNA, without copurification of DNA, is possible with DNA digestion using the RNase-Free DNase Set. A specialized protocol provides highly efficient purification of small RNA, such as miRNAs (see figure "Efficient purification of circulating miRNA"). Methylated DNA can be efficiently purified using the QIAamp Circulating Nucleic Acid Kit. The purified DNA maintains its methylation, allowing bisulfite conversion for analysis of the methylation state (see figure "Efficient recovery of methylated DNA").
The purified and concentrated circulating DNA and RNA is free of proteins, nucleases, and other impurities, and is ready to use in wide range of downstream applications, including:
- PCR and quantitative real-time PCR and RT-PCR
- Biomarker research and validation for blood-based cancer detection
- Viral nucleic acid detection
原理
The QIAamp Circulating Nucleic Acid Kit simplifies isolation of circulating DNA and RNA from plasma or serum. No phenol–chloroform extraction is required. Nucleic acids bind specifically to the QIAamp Mini column, while contaminants pass through. PCR inhibitors, such as divalent cations and proteins, are completely removed in 3 wash steps, leaving pure nucleic acids to be eluted in a buffer provided with the kit. The QIAamp Circulating Nucleic Acid technology yields circulating DNA and RNA from human plasma, serum, or urine. The QIAamp Circulating Nucleic Acid Kit combines the selective binding properties of silica-based membrane with flexible elution volumes between 20 and 150 μl. Circulating RNA can be purified with DNA digestion using the RNase-Free DNase Set.
操作手順
The QIAamp Circulating Nucleic Acid procedure includes 4 steps (lyse, bind, wash, and elute) that are carried out using QIAamp Mini columns on a vacuum manifold. The simple procedure is highly suited for simultaneous processing of multiple samples, providing nucleic acids in less than 2 hours per 24 samples. If the QIAamp Circulating Nucleic Acid Kit is used for isolation of viral RNA and DNA, the performance cannot be guaranteed for every virus species and must be validated by the user.
アプリケーション
The QIAamp Circulating Nucleic Acid Kit efficiently purifies and concentrates free-circulating DNA, RNA, miRNA, and viral nucleic acids from starting materials that contain low concentrations of mostly fragmented DNA and RNA (typically 1–100 ng/ml circulating DNA in human plasma). Starting sample volumes can be up to 5 ml. The QIAamp Circulating Nucleic Acid Kit purifies and concentrates nucleic acids from the following sample types:
|
Feature
|
Specifications
|
|
Applications
|
PCR, real-time PCR
|
|
CE/FDA/IVD compatible
|
-
|
|
Elution volume
|
20–150 µl
|
|
Format
|
QIAamp Mini Columns
|
|
Main sample type
|
Serum, plasma
|
|
Processing
|
Manual (vacuum)
|
|
Purification of total RNA, miRNA, poly A+ mRNA, DNA or protein
|
Free-circulating DNA, RNA and miRNA, viral DNA, viral RNA
|
|
Sample amount
|
1-5 ml
|
|
Technology
|
Silica technology
|
|
Time per run or per prep
|
<2 hour for 24 preps
|
|
Yield
|
Varies, due to donor-to-donor variations and disease status
|
|
|
|
|
FAQ ID -635
|
表示
|
|
|
FAQ ID -728
|
表示
|
|
|
|
|
For concentration and purification of free-circulating DNA and RNA from human plasma or serum
|
詳細を表示
|
|
|
|
詳細を表示
|
|
|
|
|
Download Safety Data Sheets for QIAGEN product components.
|
表示
|
|
|
Download Safety Data Sheets for QIAGEN product components.
|
表示
|
画像
遊離DNAの再現性の高い回収
同量のDNAフラグメント(200 bpと1000 bp)を血漿24サンプルに添加した。DNAを5 ml の血漿からQIAamp Circulating Nucleic Acid Kit で精製し、80 μl で溶出した。QuantiTect Multiplex PCR Kit を用いて、各DNAフラグメントに特異的な66 bpターゲットのduplexリアルタイムPCRを行なった。
改良されたDNAフラグメントの回収
遊離DNA を5 ml の血漿からQIAamp Circulating Nucleic Acid Kit で、1 ml の血漿からQIAamp MinElute Virus Vacuum Kit で精製し、100 μl で溶出した。QuantiTect Multiplex PCR Kit を用いて、18S rRNA遺伝子のアンプリコン66 bpと500 bpのduplexリアルタイムPCRを行なった。500 bp と66 bp のアンプリコンの増幅差はDNAのフラグメント化を示し、短い66 bp ターゲットと比較してインタクトな500 bp ターゲット配列が少なかった(この差は使用したサンプル量の5倍差より大きいことに注意)。
遊離miRNA の効率的な精製
標準プロトコールで5 ml、miRNA 専用プロトコールで 3 ml のプール血漿から、QIAamp Circulating Nucleic Acid Kit で遊離RNA を精製し、50 μl で溶出した。標準プロトコール
をmiRNA 専用プロトコールと比較した。 miRNA 30bの収量はTaqMan microRNA Assay(Applied Biosystems)で、miRNA 16の収量はHuman miScript Assay(QIAGEN)でそれぞれ定量した。miRNA プロトコールでの低いCT 値は両miRNA の収量が高いことを示唆している。
メチル化DNAの効率的な回収
メチル化DNAと非標的poly-A RNA(キャリア)を添加した血漿4 ml からQIAamp Circulating Nucleic Acid Kit を用いて精製し、45 μlで溶出した。EpiTect Bisulfite Kit (QIAGEN)を用いてBisulfite変換し、リアルタイムMSP アッセイとQuantiTect Multiplex PCR Kit の試薬を用いたMSP(methylation-specific PCR)をABI PRISM 7900HT Sequence Detection Systemで行なった。2つの完全にメチル化された遺伝子座データを解析した。
|