Investigator IDplex Kits are multiplex STR assays for human identification covering the 13 CODIS (Combined DNA Index System) core loci, D2S1338, D19S433 and Amelogenin.
The kits utilize our fast-cycling technology, enabling amplification in just 45–90 minutes, depending on the kit used. Highly sensitive with rapid and reliable results from trace DNA, the Investigator IDplex Plus Kit is suitable for all forensic applications and paternity testing. With rapid and reliable results from reference samples such as buccal swabs, as well as buccal cells or blood on papers, the Investigator IDplex GO! Kit is suitable for reference testing in forensic applications and paternity testing. The genetic analyzer is calibrated with BT5 Matrix.
Investigator IDplex Kits meet ISO 18385 requirements.
Investigator IDplex Kits utilize fast-cycling technology to provide reliable results in STR assays in just 45 minutes for reference samples with direct amplification or 90 minutes for any other sample.
The Fast Reaction Mix is based on proven QIAGEN multiplex PCR technology that has been optimized to increase inhibitor tolerance. Assay performance tested in the presence of increasing concentrations of 6 types of inhibitor (humic acid, hematin, tannic acid, indigo carmine, calcium and collagen) shows high sensitivity and superior inhibitor resistance. This enables reliable, high-quality results from casework samples, but also directly from reference samples such as blood or epithelial cells on FTA paper.
Investigator IDplex Kits were validated and evaluated using the GeneAmp 9700 thermal cycler and the Applied Biosystems 3500 Genetic Analyzer.
The recommended amount of DNA under standard conditions for use with the Investigator IDplex Plus Kit is 0.5 ng. Internal validations demonstrated robust and balanced results with 0.2–2 ng DNA, and reliable results with <0.1 ng DNA.
Investigator IDplex Kits use QIAGEN's fast-cycling PCR technology for the rapid, simultaneous amplification of the 13 CODIS (Combined DNA Index System) core loci, D2S1338, D19S433 and Amelogenin. Carefully designed primers reduce overlap of loci alleles, thereby minimizing the likelihood of misinterpretation.
The 15 polymorphic autosomal STR markers (D2S1338, D3S1358, D5S818, D7S820, D8S1179, D13S317, D16S539, D18S51, D19S433, D21S11, CSF1PO, FGA, TH01, TPOX and vWA), and the gender-specific Amelogenin are amplified simultaneously in a single PCR and labeled with one of the dyes listed in the table "Investigator IDplex Kit dyes and corresponding markers".
Dye | Marker | ||||
6-FAM | Amelogenin | TH01 | D3S1358 | vWA | D21S11 |
BTG | TPOX | D7S820 | D19S433 | D5S818 | D2S1338 |
BTY | D16S539 | CSF1PO | D13S317 | FGA | |
BTR | D18S51 | D8S1179 |
The amplified loci then undergo capillary electrophoresis. The results can be analyzed using dedicated software, such as GeneMapper ID-X. See the table "Technical specifications" for more information.
Investigator IDplex Kits are for rapid and reliable generation of DNA profiles from blood, buccal swabs and forensic stains or reference samples and are highly suited for:
Features | Investigator IDplex GO! Kit | Investigator IDplex Plus Kit |
DNA input volume | 1.2 mm FTA punch or 2 µl lysate | Up to 15 µl |
Volume per reaction | 25 µl | 25 µl |
Matrix | BT5 | BT5 |
Fluorescence dyes | 6-FAM, BTG, BTY, BTO | 6-FAM, BTG, BTY, BTO |
Genetic analyzers | ABI PRISM 3100/3100 Avant, Applied Biosystems 3130/3130xl, or Applied Biosystems 3500 Genetic Analyzers |
ABI PRISM 3100/3100 Avant, Applied Biosystems 3130/3130xl, or Applied Biosystems 3500 Genetic Analyzers |
Software for analysis | Applied Biosystems GeneMapper ID or GeneMapper ID-X |