PyroMark Q24

パイロシークエンス法を用いたメチル化定量解析、配列変異解析、微生物同定

  • メチル化解析とSNPタイピングを1回のアッセイに組み合わせ可能
  • アレルおよびメチル化状態を確実に定量
  • 配列情報から、まれな変異を発見
  • 1 ~ 24 サンプルをわずか15分で解析可能
  • 省スペースを実現するコンパクトな検出装置

PyroMark Q24 は配列情報を基にした定量解析が可能なシークエンシングプラットフォームです。PyroMark Q24 はCpG メチル化、SNP、挿入/欠失、STR、遺伝子コピー数の変動、微生物同定と抵抗性のタイピングに非常に有用なツールです。

Product Cat. no. List price:
PyroMark Q24 System
Instrument and software for Pyrosequencing analysis: includes installation, training, and 1-year warranty on parts and labor
9001514
Inquire
PyroMark Q24 Software 2.0
Analysis software, for laboratory use only
9019062
Inquire
Pyro Q24, Full Agreement

Instrument repair service for the PyroMark Q24 at regional repair center. Shipping, labor and parts included during the Full Agreement period. Loaner instrument provided within 2–3 business days. Instrument repair turnaround time of 7–10 business days. Includes one on-site Preventive Maintenance or Inspection Service during the Full Agreement period.

9241822
Details
Pyro Q24, Preventive Subscription

One on-site Preventive Maintenance or Inspection Service visit for the PyroMark Q24, including travel, labor and parts. Includes a 10% discount on repair services during the Preventive Subscription period.

9243547A
Details

PyroMark Q24 Instrument および PyroMark Q24 Software は、専用のQIAGEN キットと組み合わせて使用し、それぞれのキットハンドブックに記載されているアプリケーションで使用してください。PyroMark Q24 Instrument および PyroMark Q24 Software を特定のアプリケーションのためにQIAGEN 社製以外のキットとともに使用した場合のパフォーマンスの有効性については、ユーザーの責任範囲となります。

日本での型番とパッケージ内容は、QIAGEN機器総合カタログ をご参照ください。
CpG methylation analysis of the MLH1 gene.|Principle of Pyrosequencing — step 1.|Principle of Pyrosequencing — step 2.|Principle of Pyrosequencing — step 3.|Principle of Pyrosequencing — step 4.|Principle of Pyrosequencing — step 5.|CpG methylation pattern in the RASSF1A gene.|Workflow solutions.|Fully integrated system.|Easy data management.|Efficient template prep.|The right instrument for your needs.|
Highlighted areas in the Pyrogram trace indicate variable CpG positions (light gray) and built-in bisulfite treatment controls (yellow). The methylation level of each CpG site is indicated in blue boxes on top of the Pyrogram trace. Data kindly provided by Dr. Triantafillos Liloglou, Roy Castle Lung Cancer Foundation, Molecular Oncology, Liverpool.||||Apyrase, a nucleotide-degrading enzyme, continuously degrades unincorporated nucleotides and ATP. When degradation is complete, another nucleotide is added.||The figure illustrates the variation in methylation level between 5 different CpG sites in 4 individual tumor samples. Each sample was run in duplicate, and the concordance between the two samples clearly illustrates the reproducibility of Pyrosequencing technology.|The components of the PyroMark Q24 System are designed to make the Pyrosequencing workflow straightforward and efficient. Each step, from assay design to PCR amplification and preparation of sequencing templates, is supported by software, kits, reagents, and sample prep instrumentation optimized for Pyrosequencing.|Though small in size, the PyroMark Q24 manages all steps necessary to rapidly analyze up to 24 samples. Simply load your samples and reagents, upload your run file, and walk away. The PyroMark Q24 dispenses reagents and nucleotides to each well with precision. Light signals emitted are detected by 24 CCD sensors — one sensor per well — thereby eliminating signal crossover.|The PyroMark Q24 is designed as a stand-alone instrument, which makes it easy to place anywhere in the lab. Data are stored on the instrument hard drive and can be viewed on the instrument screen during a run. Additionally, all files are stored on the supplied USB stick, giving the user the flexibility to analyze data on any computer with PyroMark Q24 Software installed.|The PyroMark Q24 Vacuum Workstation enables conversion of PCR products into the single-stranded DNA for Pyrosequencing. Exposure of the PCR amplicons to a series of optimized solutions denatures and washes the DNA. This process is carried out for 24 samples in parallel and takes only a few minutes.|While the PyroMark Q24 combines ease-of-use, analysis versatility, and superior detection sensitivity, your workflow may demand higher throughput. The PyroMark Q96 ID and PyroMark Q96 MD accommodate this need by processing up to 96 samples in a single run. Furthermore, the automation options of the PyroMark Q96 MD enable hands-free processing of up to ten 96-well plates.|
Performance
エピジェネティクス研究に最適な検出ツール

パイロシークエンスシステムはQIAGEN のエピジェネティクス関連製品と使用することで、正確で高感度なメチル化状態の定量を実現します(図 "MLH1遺伝子のCpGメチル化解析") 。低レベルで存在する異常なDNAメチル化パターンの検出や新規の変異の同定もできます。PyroMark Q24には、Bisulfite処理の変換効率確認やCpGメチル化解析に必要なソフトウェアパッケージが含まれています。

複数のCpG部位を個別に定量

様々な腫瘍における各種の遺伝子発現を研究する場合、個々のCpG部位の解析は極めて重要です(図 "RASSF1A 遺伝子のCpGメチル化パターン")。従来の方法によるデータは解像度が低いため、十分な解析ができませんでしたが、パイロシークエンス法はこの問題点を克服し、単一のCpG部位や複数のCpG部位のメチル化パターンの単一の変化も高精度で解析できます。

Principle

パイロシークエンス法は、合成による配列解読 (sequencing by synthesis) 原理に基づいており、数分でターゲット塩基の定量解析が可能です。PyroMark Q24 はリアルタイムにシークエンス情報を提供し、エピジェネティクス研究や遺伝解析に最適な統合システムです。PyroMark Q24機器と組み合わせて、PyroMark Q24 Vacuum Workstation、PyroMark Q24 Software、PyroMark Gold Q24 Reagents、PyroMark Control Oligo、PyroMark Q24 Validation Oligo がを使用します(表を参照)。PyroMark Q24 Vacuum Workstation を使用して一本鎖DNAの調製を実現するサンプル調製用製品もお届けしています。

関連製品郡 製品説明
PyroMark Q24 変異およびメチル化の定量解析用シークエンス装置
PyroMark Q24 Vacuum Workstation 1本鎖DNAの調製を最大24サンプル同時に行なうワークステーション
PyroMark Q24 Software 解析用ソフトウェア; 2 種類の解析モードを提供(CpG 解析およびアレル定量)
PyroMark Q24 Gold Q24 Reagents 酵素、基質、ヌクレオチド
PyroMark Q24 Control Oligo システムの適切な設置と操作を評価するためのコントロール
PyroMark Q24 Validation Oligo システムの性能を確認するためのコントロール
PyroMark Q24 Tests
遺伝子解析に最適なプラットフォーム

遺伝子解析には、変異およびSNPタイピングを含むゲノムDNAの差異を解析するための様々なアプリケーションが含まれています。PyroMark Q24 は遺伝子のどのような変異解析も高い精度と感度で実現し、混在する細胞集団におけるアレルの種類を定量できます。QIAGENも、パイロシークエンス法により特定の特定の遺伝子変異を解析するための至適化・検証済み研究専用テストを提供しています。

Pyrosequencing反応の実験ステップ

ステップ1:DNAセグメントを増幅し、パイロシークエンス法のテンプレートとして使用するためにDNA鎖をビオチン化します。変性後、ビオチン化一本鎖PCRアンプリコンを単離し、シークエンシング用プライマーをハイブリダイズさせます。プライマーをアニーリングさせた一本鎖テンプレートに、酵素類であるDNA polymerase、ATP sulfurylase、luciferase 、apyrase および基質であるAPS(adenosine 5' phosphosulfate)、Luciferin と共にインキュベートします(図 "パイロシークエンシング法の原理 — ステップ 1")。

ステップ2:次に、反応液にdNTP(deoxribonucleotide triphosphate)を1種類ずつ添加します。テンプレート鎖の塩基に相補するdNTPである場合、DNA polymerase によりシークエンシング用プライマーにdNTPが付加されます。dNTPが取り込まれると、取り込まれたヌクレオチドの量に比例し、定量的にPPi (ピロリン酸) が遊離します(図 "パイロシークエンシング法の原理 — ステップ 2")。

ステップ3:ATP sulfurylase は、反応液に予め含有しているAPS と遊離したPPi によりATP を生成します。このATP はLuciferase を触媒として、このATPと反応し、Oxyluciferin へと変換され、ATPの量に比例して可視光が発生します。生じた発光は、CCDセンサにより検出され、ピーク波形(パイログラム;Pyrogram)として観察されます。各ピーク(光のシグナル)の高さは、取り込まれたヌクレオチド数に比例します(図 "パイロシークエンシング法の原理 — ステップ 3")。

ステップ4:Apyrase はヌクレオチドを分解する酵素で、反応に使用されなかったヌクレオチドおよびATPを分解します。分解が完了すると、次のヌクレオチドが添加されます("パイロシークエンシング法の原理 — ステップ 4")。

ステップ5:dNTPの添加が連続して行なわれます。基質として通常のdATP(deoxyadenosine triphosphate)の代わりにdATPαS(deoxyadenosine alfa-thio triphosphate)を使用します。これはdATPαS がLuciferase の基質にならず、DNA polymerase により効率的に使用されるからです。この連続工程により、相補的なDNA 鎖が伸長され、パイログラムにおける各発光ピークから塩基配列が決定できます("パイロシークエンシング法の原理 — ステップ 5")。

サンプルから解析までの効率的なワークフロー

適応性の高いPyroMark Q24 は、エピジェネティクスや遺伝解析のワークフローに取り入れることができ、サンプル調製、Bisulfite変換、PCR増幅のための斬新なQIAGEN テクノロジーと組み合わせて最高の結果が得られます。非常に信頼性の高い本装置は変異およびCpG部位の塩基配列の検出/定量を実現します。効率化されたワークフローにより迅速に結果が得られます。

Procedure
迅速で容易なサンプル調製 

シークエンシング用の一本鎖テンプレートをPCR産物から調製 — PyroMark Q24 Vacuum Workstation を用いて最大24 サンプルを同時に15 分以内で調製できます。ワークステーションは取り扱いが簡単で、実際のマニュアルでの作業は5分以内です。

パイロシークエンシングの前に、ビオチン化PCR産物を調製します。このビオチン化PCR産物をストレプトアビジンでコーティングされたセファロースビーズに結合させます。Vacuum WorkstationのVacuum Toolを用いてビーズを捉え、十分に洗浄した後変性し、パイロシークエンシング用の一本鎖DNAを調製します。このテンプレートDNAをシークエンシングプライマーを含むパイロシークエンシング反応プレートに入れ、プライマーアニーリングの後、プレートをPyroMark 装置にセットします。PyroMark Gold reagentは酵素、ヌクレオチド、パイロシークエンス反応の基質を含んでいます。この試薬をソフトウェアが指示する量に従い分配チップまたはカートリッジに分注し、パイロシークエンシング用の機器にセットします。

Applications

パイロシークエンス法は様々な分野でのアプリケーションでますます重要になってきています。薬剤耐性菌の検出、遺伝子発現制御におけるエピジェネティックなDNAメチル化の役割、家畜の特異的な表現型に対応する遺伝子マーカー、法医学サンプルからのミトコンドリアDNAの多型など、どのアプリケーションを実施するかにかかわらず、PyroMark Q24は遺伝子変異およびエピジェネティックな変異を解析する強力で適応性のあるツールです。さらにパイロシークエンス法は配列検出および定量を行なうので高解像度の解析が行なえ、新しい発見に繋がります。

Software
Easy-to-use PyroMark Q24 software
PyroMark Q24 software, installed on a PC, enables comprehensive analysis of your results. The software contains two analysis modes: CpG and AQ (allele quantification). Both modes can be used to analyze samples on the same plate, enabling different types of samples to be run at the same time. The AQ mode can be used for analyzing single and multivariable positions, as well as di-, tri- , and tetra- allelic mutations. The CpG mode enables analysis of multiple consecutive CpG sites and provides a built-in control for the bisulfite treatment.

Flexible and simple Pyrosequencing assay design using PyroMark Assay Design Software
PyroMark Assay Design Software 2.0 ensures easy design of PCR and sequencing primers. The assays are optimized for use with all PyroMark instruments.
Feature
Specifications
Altitude Up to 2000 m (6500 ft)
Applications Methylation analysis, allele quantification, genotyping, sequence analysis
Chemical resistance pH 4 to pH 9, common detergents, 0.5 M sodium hydroxide, ethanol
Connections One USB port (2.0)
Humidity Relative humidity of 20–90% (noncondensing)
Instrument dimensions 420 x 390 x 525 mm (16.5 x 15.4 x 20.7 in)
Kits designed for this instrument PyroMark Q24 Tests
Operating temperature 15–32°C (59–90°F)
Overvoltage category II
Place of operation For indoor use only
Pollution level 2
Power 100–240 V AC, 47–63 Hz, 1.1–0.45 A (grounded); from external power supply to the instrument : 12 VDC and 24 VDC nominal
Process temperature 28°C (82.4°F) ± 1%
Process time Depends on the number of dispensations (20 dispensations take 24 minutes)
Samples per run (throughput) 1–24
Software PyroMark Q24 Software 2.0 (to be installed on PC)
Technology Pyrosequencing
Weight 27.5 kg (60.6 lb)

You are not authorized to download the resource

FAQs
33
FAQ ID -2094
View
FAQ ID -2095
View
FAQ ID -2096
View
FAQ ID -2098
View
FAQ ID -2215
View
FAQ ID -2216
View
FAQ ID -2825
View
FAQ ID -2826
View
FAQ ID -2827
View
FAQ ID -2832
View
FAQ ID -2837
View
FAQ ID -2838
View
FAQ ID -2839
View
FAQ ID -2840
View
FAQ ID -2842
View
FAQ ID -2843
View
FAQ ID -2846
View
FAQ ID -2848
View
FAQ ID -2850
View
FAQ ID -2852
View
FAQ ID -2855
View
FAQ ID -2871
View
FAQ ID -2872
View
FAQ ID -2874
View
FAQ ID -2875
View
FAQ ID -2877
View
FAQ ID -2878
View
FAQ ID -2879
View
FAQ ID -2881
View
FAQ ID -2941
View
FAQ ID -2942
View

FAQ ID - 3473


View
FAQ ID - 3621
View
Download Files
15
Instrument methods file for use with PyroMark Q24 Software, PyroMark Gold Q24 Reagents, and PyroMark Q24 Cartridges marked with method code 0001
Show details
Instrument methods file for use with PyroMark Q24 Software, PyroMark Gold Q24 Reagents, and PyroMark Q24 Cartridges marked with method code 0002
Show details
Instrument methods file for use with PyroMark Q24 Software, PyroMark Gold Q24 Reagents, and PyroMark Q24 Cartridges marked with method code 0003
Show details
Instrument methods file for use with PyroMark Q24 Software, PyroMark Gold Q24 Reagents, and PyroMark Q24 Cartridges marked with method code 0004
Show details
Instrument methods file for use with PyroMark Q24 Software, PyroMark Gold Q24 Reagents, and PyroMark Q24 Cartridges marked with method code 0005
Show details
Instrument methods file for use with PyroMark Q24 Software, PyroMark Gold Q24 Reagents, and PyroMark Q24 Cartridges marked with method code 0006
Show details
Instrument methods file for use with PyroMark Q24 Software, PyroMark Gold Q24 Reagents, and PyroMark Q24 Cartridges marked with method code 0007
Show details
Instrument methods file for use with PyroMark Q24 Software, PyroMark Gold Q24 Reagents, and PyroMark Q24 Cartridges marked with method code 0008
Show details
Instrument methods file for use with PyroMark Q24 Software, PyroMark Gold Q24 Reagents, and PyroMark Q24 Cartridges marked with method code 0009
Show details
Instrument methods file for use with PyroMark Q24 Software, PyroMark Gold Q24 Reagents, and PyroMark Q24 Cartridges marked with method code 0010
Show details
Instrument methods file for use with PyroMark Q24 Software, PyroMark Gold Q24 Reagents, and PyroMark Q24 Cartridges marked with method code 0011
Show details
Instrument methods file for use with PyroMark Q24 Software, PyroMark Gold Q24 Reagents, and PyroMark Q24 Cartridges marked with method code 0012
Show details
Instrument methods file for use with PyroMark Q24 Software, PyroMark Gold Q24 Reagents, and PyroMark Q24 Cartridges marked with method code 0013
Show details
Instrument methods file for use with PyroMark Q24 Software, PyroMark Gold Q24 Reagents, and PyroMark Q24 Cartridges marked with method code 0014
Show details
Instrument methods file for use with PyroMark Q24 Software, PyroMark Gold Q24 Reagents, and PyroMark Q24 Cartridges marked with method code 0015
Show details
Operating Software
2
This version is compatible with Windows 7 and Windows 10 (64 bit) operating systems. This software may only be downloaded by registered users with a valid PyroMark Q24 software license and registered PyroMark Q24 instrument. If you do not have a valid software license, contact your QIAGEN sales representative.
Show details
This version is compatible with Windows 7 and Windows 10 (64 bit) operating systems. This software may only be downloaded by registered users with a valid PyroMark Q24 MDx software license and registered PyroMark Q24 MDx instrument. If you do not have a valid software license, contact your QIAGEN sales representative.
Show details
Images
Pyrogram trace illustrating CpG methylation analysis of the MLH1 gene
CpG methylation analysis of the MLH1 gene.
Highlighted areas in the Pyrogram trace indicate variable CpG positions (light gray) and built-in bisulfite treatment controls (yellow). The methylation level of each CpG site is indicated in blue boxes on top of the Pyrogram trace. Data kindly provided by Dr. Triantafillos Liloglou, Roy Castle Lung Cancer Foundation, Molecular Oncology, Liverpool.
Principle of Pyrosequencing – Step 1
Principle of Pyrosequencing — step 1.
Principle of Pyrosequencing – Step 2
Principle of Pyrosequencing — step 2.
Principle of Pyrosequencing – Step 3
Principle of Pyrosequencing — step 3.
Principle of Pyrosequencing – Step 4
Principle of Pyrosequencing — step 4.
Apyrase, a nucleotide-degrading enzyme, continuously degrades unincorporated nucleotides and ATP. When degradation is complete, another nucleotide is added.
Principle of Pyrosequencing – Step 5
Principle of Pyrosequencing — step 5.
Pyrosequencing analysis of CpG methylation pattern in the RASSF1A gene
CpG methylation pattern in the RASSF1A gene.

The figure illustrates the variation in methylation level between 5 different CpG sites in 4 individual tumor samples. Each sample was run in duplicate, and the concordance between the two samples clearly illustrates the reproducibility of Pyrosequencing technology.

Workflow solutions.
The components of the PyroMark Q24 System are designed to make the Pyrosequencing workflow straightforward and efficient. Each step, from assay design to PCR amplification and preparation of sequencing templates, is supported by software, kits, reagents, and sample prep instrumentation optimized for Pyrosequencing.
Fully integrated system.

Though small in size, the PyroMark Q24 manages all steps necessary to rapidly analyze up to 24 samples. Simply load your samples and reagents, upload your run file, and walk away. The PyroMark Q24 dispenses reagents and nucleotides to each well with precision. Light signals emitted are detected by 24 CCD sensors — one sensor per well — thereby eliminating signal crossover.

Easy data management.

The PyroMark Q24 is designed as a stand-alone instrument, which makes it easy to place anywhere in the lab. Data are stored on the instrument hard drive and can be viewed on the instrument screen during a run. Additionally, all files are stored on the supplied USB stick, giving the user the flexibility to analyze data on any computer with PyroMark Q24 Software installed.

Efficient template prep.

The PyroMark Q24 Vacuum Workstation enables conversion of PCR products into the single-stranded DNA for Pyrosequencing. Exposure of the PCR amplicons to a series of optimized solutions denatures and washes the DNA. This process is carried out for 24 samples in parallel and takes only a few minutes.

The right instrument for your needs.

While the PyroMark Q24 combines ease-of-use, analysis versatility, and superior detection sensitivity, your workflow may demand higher throughput. The PyroMark Q96 ID and PyroMark Q96 MD accommodate this need by processing up to 96 samples in a single run. Furthermore, the automation options of the PyroMark Q96 MD enable hands-free processing of up to ten 96-well plates.