Custom RT2 Profiler PCR Arrays

For reliable and sensitive gene expression profiling using laboratory-verified assays

S_1084_5_GEN_V2
Configure at GeneGlobe
Find or custom design the right target-specific assays and panels to research your biological targets of interest.
Custom RT2 PCR Array

Cat. No. / ID:  330171

96-well plate, 384-well plate, or Rotor-Disc 100 including assays, film, or cap strips
Copy order details
Configure at GeneGlobe To see pricing
For plates
Array
Additional Plate
Custom RT2 Profiler PCR Arrays are intended for molecular biology applications. These products are not intended for the diagnosis, prevention, or treatment of a disease.
Configure at GeneGlobe
Find or custom design the right target-specific assays and panels to research your biological targets of interest.

Features

  • Robust and reliable biomarker validation
  • Flexible array format for over 100,000 genes
  • Rigorous QC and QA process for accurate and reliable results
  • Designed for routine use on any real-time cycler
  • Ideal for verification of microarray or RNAseq results

Product Details

Custom RT2 Profiler PCR Arrays are sets of optimized real-time PCR primer assays on 96-well plates, 384-well plates or 100-well discs for a panel of genes related to a specific research area of interest and include appropriate RNA quality controls. Custom RT2 Profiler PCR Arrays enable gene expression analysis with real-time PCR sensitivity and the multi-gene profiling capability of a microarray for human, mouse, rat, rhesus macaque (compatible with crab-eating macaque (Macaca fascicularis, Cynomolgus monkey), cow, dog, drosophila, horse, pig, rabbit, chicken, zebrafish and CHO cells.

Performance

Sensitivity
With the sensitivity of the RT2 First Strand Kit, as little as 1 ng or as much as 5 µg of total RNA per array plate provides greater than 80% present call rates (see figure " Positive results with as little as 25 ng RNA").
Reproducibility
The complete PCR array system demonstrates strong correlations across technical replicates, lots and instruments with average correlation coefficients >0.99, ensuring reliable detection of differences in expression between biological samples (see figure " High reproducibility among different users").
Specificity
The PCR array system, with high-quality input RNA, is guaranteed to yield single bands of the predicted size without primer-dimers or other secondary products, therefore providing highly accurate real-time PCR results (see figure " A single gene-specific product in every reaction").
Uniform PCR amplification efficiency
Uniform PCR amplification efficiency is required for PCR array technology to allow accurate comparison of gene expression across all genes. The unique combination of a proprietary primer design algorithm and rigorous testing of every primer assay guarantees the high performance of every primer assay on PCR arrays (see figure " PCR arrays yield highly accurate results").
See figures

Principle

Custom RT2 Profiler PCR Arrays are reliable tools for studying and verifying gene expression biomarkers in large numbers of biological samples. Whether the biomarkers are from a proprietary collection, literature research or DNA microarray analysis, QIAGEN’s expertise in real-time PCR detection provides quality, flexibility and consistency in biomarker validation experiments. QIAGEN’s genomewide coverage provides primers for over 100,000 genes covering the human, mouse, rat, Rhesus macaque, drosophila and dog genomes.
SYBR Green-based real-time PCR is a powerful technology for studying and validating gene expression biomarkers in large numbers of biological samples. Each 96-well plate, 384-well plate or 100-well disc PCR array includes SYBR Green-optimized primer assays. The high-quality primer design and master mix formulation enable the PCR array to amplify gene-specific products simultaneously under uniform cycling conditions.
Rigorous and robust quality assurance (QA) and quality control (QC) procedures covering primer design and quality, specificity and amplification efficiency provide peace of mind.
This combination provides Custom RT2 Profiler PCR Arrays with the specificity and the high amplification efficiencies required for accurate real-time SYBR Green results. PCR arrays are easy to use in any research laboratory.

Available formats

Custom RT2 Profiler PCR Arrays are available in the following plate layouts (see the tables below and figure " Available plate layouts". Select the genes and the plate format required.

Rotor-Gene and 96-well plate or 100-well disc custom qPCR arrays
Format Number of plates (minimum)
8 genes, 12 samples per plate 12
12 genes, 8 samples per plate 12
16 genes, 6 samples per plate 12
24 genes, 4 samples per plate 24
32 genes, 3 samples per plate 24
48 genes, 2 samples per plate 24
96 genes, 1 sample per plate 24
All formats Per additional 12 array
384-plate custom qPCR arrays
Format Number of plates (minimum)
8 genes, 48 samples per plate 6
12 genes, 32 samples per plate 6
24 genes, 16 samples per plate 6
32 genes, 12 samples per plate 6
48 genes, 8 samples per plate 6
64 genes, 6 samples per plate 6
96 genes, 4 samples per plate 6
128 genes, 3 samples per plate 6
192 genes, 2 samples per plate 24
384 genes, 1 sample per plate 24
All formats Per additional 6 array

Arrays are available in additional formats or with special assay designs (position, variants, etc.), please inquire.

See figures

Procedure

Simply mix the cDNA template with the appropriate ready-to-use PCR master mix, aliquot equal volumes to each well of the same plate, and then run the real-time PCR cycling program (see flowchart " Simple procedure"). Custom RT2 Profiler PCR Arrays are compatible with all QIAGEN, ABI, Bio-Rad, Eppendorf, Roche and Stratagene instruments.

Flexible layout and controls

Custom RT2 Profiler PCR Arrays are available in 96-well plate, 384-well plate and 100-well disc formats, and are used to monitor the expression of up to 84 or 370 genes related to a specific research area of interest, plus 5 housekeeping genes. Custom RT2 Profiler PCR Arrays may also include control elements for:

  • Data normalization
  • Genomic DNA contamination detection
  • RNA sample quality
  • General PCR performance
  • Easy-to-use data analysis

Data can be analyzed using an easy-to-use Excel-based data analysis template or web-based software. Data analysis is based on the ΔΔCT method with normalization of the raw data to either housekeeping genes.

See figures

Applications

Custom or Modified RT2 PCR Profiler Arrays offer a robust platform for biomarker screening and validation and can be used in all areas of biological and medical research, including:

  • Cancer
  • Inflammation and cytokine profiling
  • Neuroscience
  • Signal transduction pathways
  • Cell adhesion and cell migration

Supporting data and figures