QuantiFast Multiplex PCR Kits

For fast, multiplex, real-time PCR and two-step qRT-PCR using sequence-specific probes

  • Sensitive detection of up to 4 targets in 1 tube
  • Faster results with time savings of up to 50%
  • Successful multiplex PCR without the need for optimization
  • Reliable quantification of low- and high-abundance targets

QuantiFast Multiplex PCR Kits enable fast and reliable quantification of up to 4 cDNA or gDNA targets in a single tube by multiplex, real-time PCR or two-step RT-PCR. Q-bond technology and an optimized master mix promote fast multiplex real-time PCR, not only on fast cyclers with short ramping times, but also on standard cyclers. The combination of a hot start and a unique PCR buffer system in the ready-to-use master mix ensures highly sensitive qPCR on any real-time cycler without the need for optimization. Two kit formats are available: the QuantiFast Multiplex PCR Kit for cyclers that require ROX dye for fluorescence normalization, and the QuantiFast Multiplex PCR +R Kit for all other cyclers. For convenience, the master mix can be stored at 2–8°C.

製品名 Cat. no. List price:
QuantiFast Multiplex PCR Kit (400)
For 400 x 25 µl reactions: 3 x 1.7 ml 2x QuantiFast Multiplex PCR Master Mix (with ROX dye), 2 x 2 ml RNase-Free Water
204654
¥85,500
QuantiFast Multiplex PCR Kit (2000)
For 2000 x 25 µl reactions: 25 ml 2x QuantiFast Multiplex PCR Master Mix (with ROX dye), 20 ml RNase-Free Water
204656
¥356,000
QuantiFast Multiplex PCR +R Kit (80)
Trial kit for 80 x 25 µl reactions: 1 ml 2x QuantiFast Multiplex PCR Master Mix (without ROX dye), 45 µl ROX Dye Solution, 2 ml RNase-Free Water
204752
Inquire
QuantiFast Multiplex PCR +R Kit (400)
For 400 x 25 µl reactions: 3 x 1.7 ml 2x QuantiFast Multiplex PCR Master Mix (without ROX dye), 210 µl ROX Dye Solution, 2 x 2 ml RNase-Free Water
204754
¥85,500
QuantiFast Multiplex PCR +R Kit (2000)
For 2000 x 25 µl reactions: 25 ml 2x QuantiFast Multiplex PCR Master Mix (without ROX dye), 1.05 ml ROX Dye Solution, 20 ml RNase-Free Water
204756
¥325,000
QuantiFast Multiplex PCR +R Kit (4000)
For 4000 x 25 µl reactions: 2 x 25 ml 2x QuantiFast Multiplex PCR Master Mix (without ROX dye), 2 x 1.05 ml ROX Dye Solution, 20 ml RNase-Free Water
204757
¥447,000

QuantiFast Multiplex PCR Kits は分子生物学実験用です。疾病の診断、治療または予防の目的には使用することはできません。


  • Main Image Navi
Significantly reduced PCR times.|Sensitive duplex PCR and wide dynamic range.|Comparable results in triplex and singleplex PCR.|Uncompromised sensitivity.|Fast primer annealing.|QIAGEN multiplex kits.|Unique PCR buffer.|Linear CT values over twofold decreases in template.|
QuantiFast Multiplex Kits reduce total PCR run time by up to 50% in real-time two-step RT-PCR (40 cycles run; comparison with QuantiTect Multiplex Kits). I: iCycler iQ; L1: LightCycler 480; L2: LightCycler 2.0; A1: ABI PRISM 7900; A2: Applied Biosystems 7500 Fast System; M: Mx3005P.
|Duplicate reactions were run on the Applied Biosystems 7500 Fast System using a DNA template mix providing 108 copies of β-actin (data shown in insets) and 106 to 10 copies of RPS27A (a ribosomal protein). The [A] QuantiFast Multiplex PCR +R Kit showed clearly higher sensitivity than the [B] duplex PCR kit from Supplier AII, enabling the cycler in fast-cycling mode to detect 10 copies of target and quantify over 6 log dilutions of template.|Triplex and singleplex PCR were carried out on the LightCycler 480 using the QuantiFast Multiplex PCR +R Kit and Primer Express designed TaqMan assays for [A] RPS27A (a ribosomal protein), [B] GAPDH (a housekeeping gene), and [C] UBC (a housekeeping gene). The template was HeLa cell cDNA (10 ng, 1 ng, or 0.1 ng), and reactions were run in duplicate. The comparable CT values for triplex PCR (colored curves) and singleplex PCR (gray curves) demonstrate the reliability of triplex PCR with the QuantiFast Multiplex PCR +R Kit when analyzing targets of differing abundance.|4-plex, real-time PCR was carried out using the QuantiFast Multiplex PCR +R Kit and Primer Express designed TaqMan assays on the Applied Biosystems 7500 Fast System. Triplicate reactions were run using 10 ng Ramos cell line cDNA.|[A] Q-Bond in QuantiFast Buffer allows the DNA polymerase and primer to bind as a single complex, reducing the annealing time to a few seconds. In addition, the unique buffer composition supports the melting of DNA, reducing denaturation and extension times. [B] Without Q-Bond, the primer and polymerase bind sequentially to the template, increasing annealing time.|QuantiFast Multiplex PCR Kits provide a simple procedure for quantitative, multiplex, real-time PCR. In contrast to current methods, the kits eliminate the need for optimization of the concentrations of primers, Mg2+, and Taq DNA polymerase, even for difficult assays (e.g., assays in which the copy number of the target gene is much smaller than that for the reference gene).|[A] NH4+ ions prevent nonspecific primers from annealing to the template. [B] Synthetic Factor MP, an innovative PCR additive, increases the local concentration of primers at the template. Together with K+ and other cations, Factor MP stabilizes specifically bound primers, allowing efficient primer extension by HotStarTaq Plus DNA Polymerase.|Duplex and singleplex PCR were carried out using the QuantiFast Multiplex PCR +R Kit and assays for the t(8;14) chromosomal translocation and for GAPDH on the Applied Biosystems 7500 Fast System. Quadruplicate reactions were run using genomic DNA from the Ramos cell line as template (twofold dilutions from 10 ng to 0.625 ng). CT values increased linearly by 1 CT value with decrease in template dilution for both the [A] singleplex and [B] duplex reactions, demonstrating the ability of the kit to precisely discriminate between small differences in template amount.|
Performance

The special master mix supplied with QuantiFast Multiplex PCR Kits allows rapid setup of multiplex reactions and delivers successful results at the first attempt, providing multiplex PCR data that are comparable with singleplex PCR data (see figure "Comparable results in triplex and singleplex PCR"). The kits can clearly distinguish between small differences in the amount of template. Even with twofold differences in template amount, QuantiFast Multiplex PCR Kits provide accurate quantification of targets of widely differing abundance (see figure "Linear CT values over twofold decreases in template").

QuantiFast Multiplex PCR Kits reduce PCR run times by up to 50%, allowing you to get results significantly faster (see figure "Significantly reduced PCR times"). As little as 10 copies of target can be detected in just 60 minutes (see figure "Sensitive duplex PCR and a wide dynamic range"). You can also greatly increase your sample throughput or efficiently share a cycler with other users. Fast results in multiplex, real-time PCR of up to 4 targets are achieved without compromising performance (see figure "Uncompromised sensitivity").

Principle

QuantiFast Multiplex PCR Kits deliver highly sensitive and rapid results over a wide dynamic range on both standard and fast cyclers without optimization (see flowchart "QIAGEN multiplex kits"). The specially developed fast PCR buffer contains the novel additive Q-Bond, which significantly reduces denaturation, annealing, and extension times (see figure "Fast primer annealing").

Amplifying reference and target genes in the same reaction instead of in separate reactions increases the reliability of gene quantification by minimizing handling errors. The QuantiFast Multiplex PCR Buffer includes a balanced combination of K+ and NH4+ ions as well as the unique synthetic Factor MP, which together promote stable and efficient annealing of primers and probes to the nucleic acid template, enabling high PCR efficiency (see figure "Unique PCR buffer"). In addition, HotStarTaq Plus DNA Polymerase provides a stringent hot start, preventing the formation of nonspecific products.

Components of 2x QuantiFast Multiplex PCR Kit*
Component Features Benefits
HotStarTaq Plus DNA Polymerase 5 min activation at 95ºC Set up of qPCR reactions at room temperature
QuantiFast Multiplex PCR Buffer Balanced combination of NH4+ and K+ ions Specific primer annealing ensures reliable PCR results
Synthetic Factor MP Reliable multiplexing analysis of up to 4 genes in the same tube
Unique Q-Bond additive Faster PCR run times, enabling faster results and more reactions per day
ROX dye Normalizes fluorescent signals on Applied Biosystems and, optionally, Agilent instruments Precise quantification on cyclers that require ROX dye. Does not interfere with PCR on any real-time cycler
* Also contains a dNTP mix (dATP, dCTP, dGTP, and dTTP).
 ROX dye is either present in the master mix or as a separate solution.
Procedure

QuantiFast Multiplex PCR Kits contain ready-to-use master mixes that eliminate the need for optimization of reaction and cycling conditions. Simply add template DNA and primer-probe sets to the master mix and follow the protocol in the handbook to get fast and reliable results on any real-time cycler. Kits are available with or without ROX passive reference dye in the master mix, enabling use on virtually any real-time cycler (see table).  Due to the optimized ROX concentrations, detection of even low copy numbers is achieved through automatic data analysis.

Choosing the right QuantiFast Multiplex PCR Kit
ROX dyeKit Compatible cyclers
Supplied in master mix QuantiFast Multiplex PCR Kit All cyclers from Applied Biosystems except Applied Biosystems 7500
Supplied in separate tube QuantiFast Multiplex PCR +R Kit Applied Biosystems 7500 and cyclers from
Bio-Rad, Cepheid, Eppendorf, QIAGEN, Roche, Agilent, and other suppliers

For optimal results in real-time two-step RT-PCR, we recommend synthesizing cDNA using the QuantiTect Reverse Transcription Kit, which provides fast cDNA synthesis in just 20 minutes with integrated removal of genomic DNA contamination.  

QuantiFast Probe Assays are predesigned, genomewide assays that use hydrolysis, probe-based detection. They are delivered with the QuantiFast Multiplex PCR Kit for guaranteed results in duplex, two-step real-time RT-PCR.

Applications

QuantiFast Multiplex PCR Kits can be used for multiplex gene expression analysis of cDNA or gDNA targets on any real-time cycler. This includes instruments from Agilent, Applied Biosystems, Bio-Rad, Cepheid, Eppendorf, and Roche. For the Rotor-Gene Q and other Rotor-Gene cyclers, we recommend using the Rotor-Gene Multiplex PCR Kit, which has been specially developed for fast cycling on these instruments.

You are not authorized to download the resource

FAQ
14
FAQ ID -1430
表示
FAQ ID -1976
表示
FAQ ID -1978
表示
FAQ ID -1979
表示
FAQ ID -1981
表示
FAQ ID -2119
表示
FAQ ID -2360
表示
FAQ ID -2371
表示
FAQ ID -2653
表示
FAQ ID -2682
表示
FAQ ID -539
表示
FAQ ID -589
表示
FAQ ID -715
表示
FAQ ID-751
表示
キットハンドブック
2
For quantitative, multiplex, real-time PCR and two-step RT-PCR with fast cycling using sequence-specific probes
詳細を表示
QuantiFast Multiplex PCR Kit - ROX passive reference dyeを含むマスターミックス添付

QuantiFast Multiplex PCR +R Kit - ROX passive reference dyeは別途包装され、マスターミックスにはROX色素を含まない

配列特異的なプローブを用いた高速なマルチプレックス・リアルタイム定量PCR/RT-PCR
詳細を表示
MSDS
1
Download Safety Data Sheets for QIAGEN product components.
表示
画像
Significantly reduced PCR times
PCR時間を顕著に短縮
QuantiFast Multiplex Kitsは2ステップリアルタイムRT-PCRで全PCR時間を最高50%まで短縮する(40サイクル、QuantiTect Multiplex Kitsと比較)。I: iCycler iQ、 L1:LightCycler 480、L2:LightCycler 2.0、A1:ABI PRISM 790、A2:Applied Biosystems 7500 Fast System、M:Mx3005P。
Sensitive duplex PCR and wide dynamic range
幅広いダイナミックレンジでの高感度なduplex PCR
108 コピーのβ-actin(挿入図)と、106 から10コピーのRPS27A(リボソームタンパク質)を含むDNAテンプレートを用いてApplied Biosystems 7500 Fast System上でduplicate反応を行なった。[A] QuantiFast Multiplex PCR +R Kit を用いた場合には、[B] AII社のduplex PCRキットに比べて感度が明らかに高く、迅速サイクリングモードのサイクラーで10コピーターゲットを検出でき、テンプレートを106 倍の希釈範囲で定量できた。
Comparable results in triplex and singleplex RT-PCR on the LightCycler 480
triplex とsingleplex PCR で同等の結果を実現
[A] RPS27A(リボソームタンパク質)、[B] GAPDH(ハウスキーピング遺伝子)、[C] UBC(ハウスキーピング遺伝子)について、Primer ExpressでデザインしたTaqManアッセイとQuantiFast Multiplex PCR +R Kitを用いてLightCycler 480上でtriplexおよびsingleplexPCRを行なった。テンプレートはHeLa細胞のcDNA(10 ng、1 ng、0.1 ng)を用いてtriplicateで行なった。Triplex PCR(色つきの曲線)とsingleplex PCR(グレーの曲線)のCT 値が類似していることから、様々な発現量のターゲットの解析でQuantiFast Multiplex PCR +R Kitを用いて信頼できるtriplex PCRが可能なことを証明している。
Uncompromised sensitivity on the Applied Biosystems 7500 Fast System.
感度を損なわずに増幅

QuantiFast Multiplex PCR +R Kit とPrimer ExpressでデザインしたTaqManアッセイを用いてApplied Biosystems 7500 Fast System上で4plexリアルタイムPCRを行なった。Ramos細胞株のcDNA 10 ngを用いてtriplicate反応を行なった。

Fast primer annealing with Q-Bond
プライマーの高速なアニーリング
[A] QuantiFast Buffer中のQ-Bondは、短い一本鎖化したDNAへのDNAポリメラーゼの結合アフィニティーを増大させるため、プライマーのアニーリング時間を数秒間に短縮できる。さらにDNAの融解をサポートするユニークなバッファー組成が、変性およびエクステンション時間を短縮する。[B] Q-Bond が存在しないと、プライマーとポリメラーゼが連続的にテンプレートに結合するのでプライマーのアニーリングに時間がかかる。
Successful Multiplex PCR-Based Genotypic Analysis without the Need for Optimization
QIAGEN multiplex kits
QuantiFast Multiplex PCR Kitsは、簡単な操作でマルチプレックスリアルタイムRT-PCRを実現する。汎用されている方法に比べて、本キットはプライマー、プローブ、Mg2+Taq DNA polymeraseの濃度に対する至適化が不要で、リファレンス遺伝子に比べてターゲット遺伝子のコピー数が少ないアッセイでも同様。
Unique Type-it Microsatellite PCR Buffer Promotes Stable and Efficient Annealing
ユニークなPCRバッファー
[A] NH4+ イオンは非特異的なプライマーのテンプレートへのアニーリングを防ぐ。[B]画期的なPCR添加物であるFactor MP は、テンプレート周辺でのプライマー濃度を高める。K+ や他の陽イオンと共に、Factor MPは特異的に結合したプライマーを安定化し、HotStarTaq Plus DNA Polymeraseによる効果的なプライマーエクステンションを可能にする。
Linear Ct values over twofold decreases in template on the Applied biosystems 7500 Fast System.
テンプレート量の連続2倍希釈液でも直線性の高いCT値
QuantiFast Multiplex PCR +R Kitを用いて、Applied Biosystems 7500 Fast System上でt(8;14)染色体転座とGAPDH用のアッセイのためのduplexおよびsingleplex PCRを行なった。テンプレートとしてRamos 細胞株のゲノムDNA(10 ngから0.625 ngの2倍希釈)を用いてQuadruplicate反応を行なった。[A] singleplexと[B] duplex反応の両方でテンプレートの希釈に伴いCT 値は1 CTずつ直線性を持って増大したことは、本キットがテンプレート量の微量な差異も正確に定量できることを証明している。