artus HI Virus-1 RT-PCR Kits CE

For quantitative detection of HIV-1 specific RNA using real-time PCR
  • Complete CE-IVD-compliant workflow from sample to detection
  • High reliability using the internal control
  • Highly sensitive detection of as few as 76.4 IU/ml
  • Specific detection of HIV-1 genotypes A to H
  • Accurate quantitation of viral load over a very broad range
The artus HI Virus-1 RG RT-PCR Kit and the artus HI Virus-1 QS-RGQ Kit are ready-to-use molecular detection kits for real-time RT-PCR on Rotor-Gene Q instruments. The kits provide all necessary reagents optimized for reliable HIV-1 RNA detection and quantitation for in vitro diagnostic use. The artus HI Virus-1 RG RT-PCR Kit uses manual sample preparation and assay setup techniques. The artus HI Virus-1 QS-RGQ Kit is part of the QIAsymphony RGQ, the complete automated system from sample to pathogen detection, and is not for use with manual assay setup.
产品 货号 目录价:
artus HI Virus-1 QS-RGQ Kit (72) CE
For 72 reactions on the QIAsymphony RGQ: 2 Masters, 4 Quantitation Standards, Internal Control, Water (PCR grade)
4513366
询价
artus HI Virus-1 RG RT-PCR Kit (24) CE
For 24 reactions on Rotor-Gene Q instruments: 2 Masters, 4 Quantitation Standards, Internal Control, Water (PCR grade)
4513263
询价
artus HI Virus-1 RG RT-PCR Kit (96) CE
For 96 reactions on Rotor-Gene Q instruments: 2 Masters, 4 Quantitation Standards, Internal Control, Water (PCR grade)
4513265
询价
artus HI Virus-1 QS-RGQ Kit (24) CE
For 24 reactions on the QIAsymphony RGQ: 2 Masters, 4 Quantitation Standards, Internal Control, Water (PCR grade)
4513363
询价

artus HI Virus-1 RT-PCR Kits CE可在欧洲用于体外诊断。


  • Main Image Navi
HIV-1病毒载量的可靠定量。|HIV-1.|HIV-1病毒RNA的高敏感度检测。|CE体外诊断认证。|在某些国家可用于体外诊断。|可使用QIAsymphony RGQ自动化检测HIV-1病毒。|
在Rotor-Gene Q/6000的Cycling Green荧光信道或、Rotor-Gene 3000的A.FAM信道上检测定量标准品(HI Virus-1 RG QS 1–4)。NTC:无模板对照(阴性对照)。||概率分析:HI Virus-1(QIAsymphony RGQ)。artus HI Virus-1 QS-RGQ Kit与QIAsymphony RGQ仪器共同使用的分析敏感度。||||
性能

To ensure highest sensitivity, artus HI Virus-1 Kits have been optimized to detect low numbers of HIV-1 RNA. The analytical sensitivity of the artus HI Virus-1 QS-RGQ Kits is 76.4 IU/ml in consideration of the purification and assay setup using the QIAsymphony RGQ system (see figure "Highly sensitive detection of HIV-1 RNA"). (1 IU/ml corresponds to 0.45 copies/ml for detection of HIV-1 RNA on the Rotor-Gene Q. The conversion factor is an approximation based on an average factor across the assay's dynamic range.)

For highest specificity, validation of the artus HI Virus-1 Kits was carried out using various HIV-1 isolates, including all group M subtypes A–H, and related pathogens.

Performance characteristics of artus HI Virus-1 Kits
Kit  artus HI Virus-1 RG RT-PCR Kitartus HI Virus-1 QS-RGQ Kit
Validated sample type  Human EDTA plasma Human EDTA plasma
Analytical sensitivity  66.9 IU/ml 76.4 IU/ml (corresponding to 34.4 copies/ml)
 Linear range  120 to >1 x 108 IU/ml  1 x 102 to 1 x 108 IU/ml (corresponding to 4.5 x 101 to 4.5 x 107 copies/ml)
 Specificity  HIV-1, including all group M subtypes A–H  HIV-1, including all group M subtypes A–H

原理

The artus HI Virus-1 RG RT-PCR Kit and the artus HI Virus-1 QS-RGQ Kit are based on the amplification and simultaneous detection of a specific region of the HIV-1 genome using real-time RT-PCR. The kits provide high levels of specificity, sensitivity (see figure "Highly sensitive detection of HIV-1 RNA"), and reproducibility over a broad linear range.
Each artus HI Virus-1 Kit provides 4 HIV-1 quantitation standards (see figure "Reliable quantitation of HIV-1 load"). Use of the standards enables accurate quantitation of viral load. In addition, the kits contains a second heterologous amplification system to identify possible PCR inhibition. This is detected as an internal control (IC) in a different fluorescence channel from the analytical PCR. The detection limit of the analytical HIV-1 PCR is not reduced.

Specifications of artus HI Virus-1 Kits
Kitartus HI Virus-1 RG RT-PCR Kit and artus HI Virus-1 QS-RGQ Kit
Validated sample type Human EDTA plasma
Amplicon 93 nt region of the 5' LTR

操作流程

artus HI Virus-1 RT-PCR Kits provide all necessary reagents optimized for reliable HIV-1 RNA detection and quantitation. Simply add template RNA to the ready-to-use PCR master mix, and start the reaction on the appropriate real-time cycler using the optimized cycling program described in the kit handbook.

Complete automated system from sample to HIV-1 detection

The QIAsymphony RGQ workflow solution for HIV-1 detection comprises the QIAsymphony SP for sample preparation, the QIAsymphony AS for assay setup, and the artus HI Virus-1 QS-RGQ Kit on the Rotor-Gene Q. The system enables reliable pathogen detection with a complete CE-IVD-compliant workflow (see figure "Integrated QIAsymphony RGQ system for HIV-1 detection").

Recommendations for manual viral RNA purification

The artus HI Virus-1 RG RT-PCR Kit is validated for use with viral RNA purified from human plasma using the CE-marked QIAamp DSP Virus Kit.

应用

The artus HI Virus-1 RG RT-PCR Kit enables rapid and sensitive detection and quantitation of HIV-1 RNA purified from human plasma using the QIAamp DSP Virus Kit.

The artus HI Virus-1 QS-RGQ Kit is designed to be used with the QIAsymphony RGQ system, providing a complete CE-IVD-compliant workflow from sample to HIV-1 RNA detection and quantitation.

您无权限查看此资源

实验方案软件
1
For use with QIAsymphony SP/AS instruments (software version 4.0)
显示更多
仪器技术参数
1
安全数据表
1
Download Safety Data Sheets for QIAGEN product components.
浏览
图片
Reliable quantitation of HIV-1 load
HIV-1病毒载量的可靠定量。
在Rotor-Gene Q/6000的Cycling Green荧光信道或、Rotor-Gene 3000的A.FAM信道上检测定量标准品(HI Virus-1 RG QS 1–4)。NTC:无模板对照(阴性对照)。
HIV-1
HIV-1.
Highly sensitive detection of HIV-1 RNA
HIV-1病毒RNA的高敏感度检测。
概率分析:HI Virus-1(QIAsymphony RGQ)。artus HI Virus-1 QS-RGQ Kit与QIAsymphony RGQ仪器共同使用的分析敏感度。
CE-IVD marked Symbol
CE体外诊断认证。
SYM_0002_IVD
在某些国家可用于体外诊断。
Integrated QIAsymphony RGQ system for HIV-1 detection
可使用QIAsymphony RGQ自动化检测HIV-1病毒。