ProductFinder helps you to find the best QIAGEN product for your application. Make your selections and you will find the most suitable products.

27 results found with selected category.

digene HC2 High-Risk HPV DNA Test

For detection of human papillomavirus infections using Hybrid Capture 2 technology

    • Detection of 13 high-risk HPV types
    • High clinical sensitivity proven by extensive clinical validation
    • Standardized, objective results
    • HPV test for in vitro diagnostic use
    • Uses full genome probes
digene Accessories
Accessories for use with digene HC2 DNA Tests
EASYartus RG PCR Kits CE

For CE-IVD-marked integrated automated sample purification and pathogen detection

    • CE-IVD-marked automated processing of clinical samples
    • Pathogen load monitoring in patients
    • Cost-efficient patient management
    • Standardized integrated system for time savings and ease of use
artus Malaria RG PCR Kit RUO
For quantitative detection of Plasmodium specific DNA using real-time PCR
    • High reliability using the internal control
    • Sensitive detection of as few as 0.5 copies/µl
    • Accurate quantitation using the 4 standards supplied
artus Malaria RG PCR Kit CE
For quantitative detection of Plasmodium specific DNA using real-time PCR
    • Compliance with EU IVD Directive 98/79/EC
    • High reliability using the internal control
    • Highly sensitive detection of as few as 0.5 copies/µl
    • Accurate quantitation using the 4 standards supplied
artus M. tuberculosis PCR Kits RUO
For quantitative detection of DNA of members of the M. tuberculosis complex using ...
    • High reliability using the internal control
    • Sensitive detection of as few as 0.23 copies/µl (RG kit)
    • Accurate quantitation using the 4 standards supplied
artus Mycobac. diff. LC PCR Kit CE

For quantitative detection of mycobacterial DNA and differentiation of species and ...

    • Compliance with EU IVD Directive 98/79/EC
    • High reliability using the internal control
    • Sensitive detection of as few as 1.5 copies/µl (LightCycler 1.1/1.2/1.5)
    • Accurate quantitation using the 4 standards supplied
artus Infl./H1 LC/RG RT-PCR Kit RUO

For detection of influenza A/B RNA and specific detection of influenza A (H1N1) RNA ...

    • High reliability using the internal control
    • Sensitive detection of influenza viruses A and B
    • Specific detection of novel influenza H1N1
    • Ready-to-use reaction mixes
artus Mycobac. diff. LC PCR Kit RUO

For quantitative detection of mycobacterial DNA and differentiation of species and ...

    • High reliability using the internal control
    • Sensitive detection of as few as 1.5 copies/µl (LightCycler 1.1/1.2/1.5)
    • Accurate quantitation using the 4 standards supplied
artus WNV LC RT-PCR Kit CE
For quantitative detection of West Nile virus RNA using real-time PCR
    • Compliance with EU IVD Directive 98/79/EC
    • High reliability using the internal control
    • Highly sensitive detection of as few as 2.4 copies/µl
    • Accurate quantitation using the 4 standards supplied
artus Parvo B19 PCR Kits RUO
For quantitative detection of parvovirus DNA using real-time PCR
    • High reliability using the internal control
    • Sensitive detection of as few as 0.2 IU/µl (ABI PRISM 7000)
    • Accurate quantitation using the 5 standards supplied
artus VZV PCR Kits CE
For quantitative detection of varicella-zoster virus specific DNA using real-time PCR
    • Complete CE-IVD-compliant workflow (QIAsymphony RGQ)
    • High reliability using the internal control
    • Highly sensitive detection of as few as 19.2 copies/ml (QS-RGQ kit)
    • Accurate quantitation using the 4 standards supplied
artus Parvo B19 PCR Kits CE
For quantitative detection of parvovirus DNA using real-time PCR
    • Compliance with EU IVD Directive 98/79/EC
    • High reliability using the internal control
    • Highly sensitive detection of as few as 0.2 IU/µl (RG kit)
    • Accurate quantitation using the 5 standards supplied
artus SARS RG RT-PCR Kit CE

For quantitative detection of SARS coronavirus RNA using real-time PCR

    • Compliance with EU IVD Directive 98/79/EC
    • High reliability using the internal control
    • Highly sensitive detection of as few as 0.5 copies/µl
    • Accurate quantitation using the 4 standards supplied
artus HSV-1/2 PCR Kits CE
For detection and differentiation of HSV-1/2 specific DNA using real-time PCR
    • Complete CE-IVD-compliant workflow (QIAsymphony RGQ)
    • High reliability using the internal control and positive controls
    • Highly sensitive detection of as few as 43.2 copies/ml (QS-RGQ kit)
    • Same temperature profile for multiple viruses (RG and QS-RGQ kits only)
artus BK Virus PCR Kits CE
For quantitative detection of BK virus specific DNA using real-time PCR
    • Complete CE-IVD-compliant workflow (QIAsymphony RGQ)
    • High reliability using the internal control
    • Highly sensitive detection of as few as 26.7 copies/ml (QS-RGQ kit)
    • Accurate quantitation using the 4 standards supplied
artus Borrelia LC PCR Kit CE
For quantitative detection of Borrelia DNA using real-time PCR
    • Compliance with EU IVD Directive 98/79/EC
    • Highly sensitive detection of as few as 2.8 copies/µl (LightCycler 2.0)
    • Specific detection of all members of Borrelia burgdorferi sensu lato
    • High reliability using the internal control
    • Accurate quantitation over a very broad range
artus Enterovirus LC RT-PCR Kit RUO
For quantitative detection of enterovirus RNA using real-time PCR
    • High reliability using the internal control
    • Sensitive detection of as few as 3.2 copies/µl
    • Accurate quantitation using the 4 standards supplied
artus HAV TM RT-PCR Kit v2.0 RUO
For quantitative detection of hepatitis A virus RNA using real-time PCR
    • High reliability using the internal control
    • Sensitive detection of as few as 0.1 IU/µl
    • Accurate quantitation using the 4 standards supplied
artus HI Virus-1 RT-PCR Kits CE
For quantitative detection of HIV-1 specific RNA using real-time PCR
    • Complete CE-IVD-compliant workflow from sample to detection
    • High reliability using the internal control
    • Highly sensitive detection of as few as 76.4 IU/ml
    • Specific detection of HIV-1 genotypes A to H
    • Accurate quantitation of viral load over a very broad range
artus HBV PCR Kits CE
For quantitative detection of hepatitis B virus DNA using real-time PCR
    • Complete CE-IVD-compliant workflow (QIAsymphony RGQ)
    • High reliability using the internal control
    • Highly sensitive detection of as few as 10.2 IU/ml (QS-RGQ kit)
    • Broad linear range from 31.6 to more than 20,000,000 IU/ml (QS-RGQ kit)
    • Accurate quantitation using the 5 standards supplied
artus HCV RT-PCR Kits CE
For quantitative detection of HCV specific RNA using real-time RT-PCR
    • Complete CE-IVD-compliant workflow (QIAsymphony RGQ)
    • High reliability using the internal control
    • Highly sensitive detection of as few as 21 IU/ml
    • Accurate quantitation of viral load over a very broad linear range
artus Aspergillus diff. RG PCR Kit RUO
For amplification and differentiation of Aspergillus spp. DNA
    • High reliability using the internal control
    • Sensitive detection of Aspergillus spp.
    • Differentiation of Aspergillus fumigatus/terreus/flavus DNA
    • Ready-to-use reaction mixes
artus CT/NG QS-RGQ Kit CE
For qualitative detection of Chlamydia trachomatis and Neisseria gonorrhoeae DNA
    • CE-IVD-compliant workflow on the QIAsymphony RGQ
    • High reliability through use of an internal control
    • Excellent detection limit for swabs and urine
artus CMV PCR Kits CE
For quantitative detection of cytomegalovirus DNA using real-time PCR
    • Complete CE-IVD-compliant workflow (QIAsymphony RGQ)
    • High reliability using the internal control
    • Highly sensitive detection of as few as 42.5 copies/ml (QS-RGQ kit)
    • Accurate quantitation of viral load over a very broad linear range
artus EBV PCR Kits CE
For quantitative detection of Epstein-Barr virus DNA using real-time PCR
    • CE-marked IVD workflow (QIAsymphony RGQ)
    • High reliability using the internal control
    • Highly sensitive detection of as few as 157 copies/ml (QS-RGQ kit)
    • Accurate quantitation of viral load over a very broad linear range
QuantiFERON-TB Gold (QFT) Kit
An aid to the detection of Mycobacterium tuberculosis (TB) infection (1)
    • Accurate and unaffected by prior BCG vaccination (2–4)
    • Efficient, with results after one patient visit (1) 
    • Objective results (1) 
    • Proven performance in immunosuppressed patients (5–8)