text.skipToContent text.skipToNavigation

RNeasy Plus Micro Kit

For purification of up to 45 µg total RNA from cells/tissues using gDNA Eliminator columns

  • Unique gDNA Eliminator columns avoid the need for DNase
  • Efficient removal of genomic DNA
  • Highly reproducible yields of RNA in minutes
  • High-performance RNA for sensitive applications
The RNeasy Plus Micro Kit integrates fast, convenient purification of up to 45 µg RNA with effective elimination of genomic DNA. Cell or tissue lysates are spun through gDNA Eliminator spin columns to remove genomic DNA. Total RNA is then purified using RNeasy MinElute spin columns. Tissue samples can be conveniently stabilized using RNAlater RNA Stabilization Reagent or Allprotect Tissue Reagent, and efficiently disrupted using a TissueRuptor or TissueLyser system. For larger samples, the RNeasy Plus Mini Kit (spin-column binding capacity of 100 µg RNA) is also available. Procedures can be fully automated on the QIAcube.
Cat No./ID: 74034
RNeasy Plus Micro Kit (50)
S Fr.528.00
Add To Cart
For 50 micropreps: RNeasy MinElute Spin Columns, gDNA Eliminator Spin Columns, Collection Tubes, Carrier RNA, RNase-Free Water and Buffers
The RNeasy Plus Micro Kit is intended for molecular biology applications. This product is not intended for the diagnosis, prevention, or treatment of a disease.
0
RNeasy Plus procedure.

A short workflow enables RNA purification with genomic DNA removal in less than 30 minutes.

1
High, reproducible RNA yields.
Total RNA was purified from 10-fold serial dilutions of Jurkat cells (5 x 105 to 5 cells) using the RNeasy Plus Micro Kit; at each dilution, RNA was purified from 4 replicates. β-actin transcript was detected in down to 5 cells by real-time RT-PCR, and reproducible CT values were observed at each dilution. In control reactions without reverse transcriptase (-RT), β-actin DNA was not detected after 38 cycles, indicating the absence of genomic DNA contamination.
Performance
The RNeasy Plus Micro procedure integrates selective removal of double-stranded DNA with RNeasy technology. After genomic DNA removal, high-quality RNA is purified using RNeasy MinElute spin columns. This allows high, reproducible RNA yields and effective elimination of genomic DNA contamination for sensitive applications (see figure "High, reproducible RNA yields"). Total RNA with Agilent RIN values of close to 10 is routinely obtained from tissues and cultured cells.
Principle

Cells and easy-to-lyse tissues are first lysed and homogenized in highly denaturing guanidine-isothiocyanate–containing Buffer RLT Plus, which immediately inactivates RNases to ensure isolation of intact RNA. The lysate is then passed through a gDNA Eliminator spin column that, in combination with the high-salt buffer, selectively and efficiently removes genomic DNA. Ethanol is added to provide appropriate binding conditions for RNA, and the sample is applied to an RNeasy MinElute spin column. These specialized columns each contain a silica membrane that specifically binds RNA from lysed cells.

Procedure

Total RNA is purified from up to 5 x 105 cells or 5 mg tissue, making the RNeasy Plus Micro Kit well suited for small samples. A short workflow enables RNA purification with genomic DNA removal in less than 30 minutes (see flowchart "RNeasy Plus procedure").  Samples are first lysed and homogenized. The lysate is passed through a gDNA Eliminator spin column, ethanol is added to the flow-through, and the sample is applied to an RNeasy MinElute spin column. RNA binds to the membrane and contaminants are washed away. High quality RNA is eluted in as little as 14 µl water.

Different protocols are available for different starting materials. The protocols differ mainly in the lysis and homogenization of the sample. Once the sample is applied to the gDNA Eliminator spin column, the protocols are similar. The procedure provides an enrichment for mRNA since most RNAs <200 nucleotides (such as rRNAs and tRNAs) are excluded. The RNeasy Plus procedure can be modified to allow the purification of total RNA containing small RNAs, such as miRNA, from cultured cells. 

When disrupting and homogenizing tissues in Buffer RLT Plus (supplied with the RNeasy Plus Micro Kit), excessive foaming may occur. This foaming is substantially reduced by adding Reagent DX (supplied separately) to Buffer RLT Plus before starting disruption and homogenization. Reagent DX has been carefully tested with the kit, and has no effect on RNA purity or on downstream applications.

Applications

RNA purified using the RNeasy Plus Micro Kit is ideally suited for downstream applications that are sensitive to low amounts of DNA contamination, such as quantitative real-time RT-PCR. The purified RNA can also be used in other applications.

The RNeasy Plus Micro Kit is suitable for small samples, including:

Laser-microdissected cryosections
Fine-needle aspirates
Features
Specifications
Applications null
Elution volume null
Format null
Integrated removal of genomic DNA null
Main sample type null
Processing null
Purification of total RNA, miRNA, poly A+ mRNA, DNA or protein null
Sample amount null
Technology null
Time per run or per prep null
Yield null

You are not authorized to download the resource

FAQs (17)
FAQ ID -1024
View
FAQ ID -1043
View
FAQ ID -1164
View
FAQ ID -1734
View
FAQ ID -1749
View
FAQ ID -1750
View
FAQ ID -1996
View
FAQ ID -2793
View
FAQ ID -2794
View
FAQ ID -2796
View
FAQ ID -2797
View
FAQ ID - 3390
View
FAQ ID - 3560
View
FAQ ID -627
View
FAQ ID -728
View
FAQ ID -2248
View
FAQ ID -530
View
Kit Handbooks (2)
gDNA Eliminatorカラムを用いた動物およびヒト細胞、マイクロダイセクション法により採取した凍結切片微量サンプルからのトータルRNA精製、およびRNAのクリーンアップと濃縮
Show details
For purification of total RNA using gDNA Eliminator columns from small samples, including
  • animal and human cells (≤5 x 10^5)
  • animal and human tissues (≤5 mg)
  • microdissected cryosections
and for RNA cleanup and concentration
Show details
fragment fix placeholder

Customers who bought these products also bought