QIAstat-Dx COVID-19 research

QIAstat-Dx

For multiplex syndromic applications

  • Detection of 22 respiratory targets including 2019-nCoV (SARS-CoV-2)
  • Targets SARS-CoV-2 Orf1ab and E genes (similar to WHO-Charité test)
  • Utilizes real-time PCR to deliver results with Ct values and amplification curves
  • Cartridge accepts both dry swabs and transport medium liquid samples
  • Research use only

 

To support the research efforts for accessible testing to meet the demands of the COVID-19 outbreak, QIAGEN developed the QIAstat-Dx Respiratory 2019-nCoV Panel. This version of our multiplex syndromic cartridge detects and differentiates 22 respiratory targets, including 2019-nCoV (SARS-CoV-2) from Nasopharyngeal swabs (NPS).

The QIAstat-Dx Analyzer, combined with QIAstat-Dx assay cartridges, uses real-time PCR to detect pathogen nucleic acids in human biological samples. The QIAstat-Dx Analyzer and cartridges are designed as a closed system that enables hands-off sample preparation followed by detection and identification of pathogen nucleic acids. Samples are inserted into a QIAstat-Dx cartridge, which contains all the reagents to isolate and amplify nucleic acids from the sample. Detected real-time amplification signals are interpreted by the integrated software and are reported via an intuitive user interface.


Find out more about QIAstat-Dx, learn about its panels, watch webinars and more.

Product Cat. no. List price:
QIAstat-Dx Analytical Module
Module contains the hardware and software for sample testing and analysis.
9002814
Log in
QIAstat-Dx Analyzer
Instrument consists of both the Operational Module and Analytical Module.
9002824
Log in
QIAstat-Dx Operational Module
Module enables interaction with the QIAstat-Dx Analyzer.
9002813
Log in
QIAstat-Dx Respiratory 2019-nCoV Panel

Six individually packaged cartridges containing all reagents needed for sample preparation and multiplex real-time PCR plus internal control, including six transfer pipettes

691212
Log in

QIAstat-Dx Respiratory 2019-nCoV Panel is for research use only. QIAstat-Dx Respiratory 2019-nCoV Panel is run on the QIAstat-Dx Analyzer.



Feature
Specifications
Altitude Up to 2000 m (6500 ft.)
Elution volume QIAsymphony SP — 30–500 µl (application dependent)
Features Rotor-Gene Q — dynamic range, 10 orders of magnitude
Heat dissipation/thermal load Rotor-Gene Q — average, 0.183 kW (632 BTU/hour); peak, 0.458 kW (1578 BTU/hour)
Humidity QIAsymphony SP/AS — relative humidity of 15–75% (noncondensing); maximum 75% relative humidity for temperatures up to 31°C, decreasing linearly to 50% humidity at 32°C
Rotor-Gene Q — relative humidity of 10–75% (noncondensing)
Input volume QIAsymphony SP — minimum input volume: 200 µl (application dependent)
Instrument dimensions QIAsymphony SP/AS — QIAsymphony SP, 128 x 103 x 73 cm; QIAsymphony AS, 59 x 103 x 73 cm; QIAsymphony SP/AS (integrated operation), 185 x 103 x 73 cm
Rotor-Gene Q — width, 37 cm (14.6 in.); height, 28.6 cm (11.3 in.); depth (without cables), 42 cm (16.5 in.); depth (door open), 53.8 cm (21.2 in.)
Kits or Application Packs designed for this instrument QIAsymphony SP — QIAsymphony DSP Virus/Pathogen Kits and other QIAsymphony Kits; QIAsymphony AS — artus QS-RGQ Kits (not available in all countries), Rotor-Gene Kits and other QIAGEN real-time and end-point PCR kits
Rotor-Gene Q — artus QS-RGQ Kits (not available in all countries), RG SYBR Green PCR Kits; RG SYBR Green RT-PCR Kit; RG Probe PCR Kits; RG Probe RT-PCR Kit; RG Multiplex PCR Kit
Operating temperature QIAsymphony SP/AS — 15–32°C (59–89.6ºF)
Rotor-Gene Q — 18–30ºC (64–86ºF)
Optical System Rotor-Gene Q — up to 6 channels spanning UV to infra-red wavelengths; excitation sources: high energy light-emitting diodes; detector: photomultiplier; acquisition time: 4 s; the software allows to create new excitation/detection wavelength combinations
Overvoltage category II
Place of operation For indoor use only
Pollution level QIAsymphony SP/AS — 2
Rotor-Gene Q — 2; Environmental class 3K2 (IEC 60721-3-3)
Power QIAsymphony SP/AS — 100–240 V AC, 50–60 Hz, 1400 VA, mains supply voltage are not to exceed 10% of nominal supply voltages
Rotor-Gene Q — 100–240 V AC, 50–60 Hz, 520 VA (peak); Power consumption 8 VA (standby); Mains supply voltage fluctuations are not to exceed 10% of the nominal supply voltages; F5A 250 V fuse
Processing QIAsymphony SP/AS — automated
Protocols/main application on this instrument QIAsymphony SP — purification of DNA, RNA, and bacterial and viral nucleic acids from a wide range of starting materials
QIAsymphony AS — PCR setup
Rotor-Gene Q — gene expression analysis, microRNA detection, virus detection, SNP genotyping, SNP genotyping, High Resolution Melt analysis (HRM)
Samples per run (throughput) QIAsymphony SP — 1–96 samples in batches of 24
Rotor-Gene Q — tubes 0.2 ml; strip tubes 0.1 ml (4 tubes); Rotor-Disc 72; Rotor-Disc 100; up to 100 samples per run using a Rotor-Disc 100
Software Rotor-Gene Q — Rotor-Gene Q software, supplied on the provided installation CD
Storage temperature QIAsymphony SP/AS — 5–40°C (41ºF to 104ºF) in manufacturer's package
Rotor-Gene Q — 15 to 30ºC (59ºF to 86ºF) in manufacturer’s package; max. 75% relative humidity (noncondensing); environmental class 1K2 (IEC 60721-3-1)
Technology QIAsymphony SP — QIAGEN magnetic-particles chemistry
Rotor-Gene Q — real-time PCR cycler
Thermal performance Rotor-Gene Q — temperature range, 35 to 99ºC; temperature accuracy, ±0.5ºC (type, measured 30 seconds after clock start); temperature resolution, ±0.02ºC (smallest programmable increment); temperature uniformity, ±0.02ºC; ramp rate (peak ramp rates, air), >15ºC/s heating, >20ºC/s cooling
Transportation conditions QIAsymphony SP/AS — –25 to 70°C (–13ºF to 158ºF) in manufacturer's package
Rotor-Gene Q — –25 to 60ºC (–13ºF to 140ºF) in manufacturer’s package; max. 75% relative humidity (noncondensing); environmental class 2K2 (IEC 60721-3-2)
Typical run time Rotor-Gene Q — 40 cycles in 45 min with the QIAGEN RG Kits (assay dependent)
Warranty Rotor-Gene Q — 1 year on instrument; lifetime guarantee on excitation LEDs
Weight QIAsymphony SP, 175 kg; QIAsymphony AS, 90 kg; QIAsymphony SP/AS (integrated operation), 265 kg; Rotor-Gene Q, 12.5 kg (27.6 lb.) (standard configuration)

You are not authorized to download the resource

Instrument User Manuals
6
For use with software version 1.2.x or higher
Show details
For use with software version 1.3.x or higher
Show details
For use with software version 1.2.x or higher
Show details
For use with software version 1.4.x or higher
Show details
For use with software version 1.5.1 or higher

Show details
For use with software version 1.5.2 or higher

Show details
Safety Data Sheets
1
Download Safety Data Sheets for QIAGEN product components.
View
Operating Software
5
For use with the QIAstat-Dx Analyzer and the DiagCORE Analyzer
Show details
For use with the QIAstat-Dx Analyzer and the DiagCORE Analyzer
Show details
For use with the QIAstat-Dx Analyzer and the DiagCORE Analyzer
Show details
For use with the QIAstat-Dx Analyzer and the DiagCORE Analyzer
Show details
For use with the QIAstat-Dx Analyzer and the DiagCORE Analyzer

Show details