For purification of up to 10 μg PCR products, 100 bp to 10 kb
  • Up to 95% recovery of ready-to-use DNA
  • Cleanup of DNA up to 10 kb in three easy steps
  • Gel loading dye for convenient sample analysis

The QIAquick PCR Purification Kit provides spin columns, buffers, and collection tubes for silica-membrane-based purification of PCR products >100 bp. DNA of up to 10 kb is purified using a simple and fast bind-wash-elute procedure and an elution volume of 30–50 μl. An optional pH indicator allows easy determination of the optimal pH for DNA binding to the spin column. The procedure can be fully automated on the QIAcube.

Quantity Product Cat. no. Price
 
 
show details
  varies
Quantity Product Cat. no. Price Sum
 
QIAquick PCR Purification Kit (50)
For purification of 50 PCR reactions: 50 QIAquick Spin Columns, Buffers, Collection Tubes (2 ml)
28104
$108.00
$0.00
 
QIAquick PCR Purification Kit (250)
For purification of 250 PCR reactions: 250 QIAquick Spin Columns, Buffers, Collection Tubes (2 ml)
28106
$514.00
$0.00
The QIAquick PCR Purification Kit is intended for molecular biology applications. This product is not intended for the diagnosis, prevention, or treatment of a disease.
  • Main Image Navi
QIAquick and MinElute procedure.|Complete primer removal after PCR.|GelPilot Loading Dye.|pH Indicator Dye.|Spin column handling options — D.|Spin column handling options — E.|Spin column handling options — C.|Spin column handling options — B.|Spin column handling options — A.|
The QIAquick and MinElute systems use a simple bind-wash-elute procedure with spin columns or a vacuum manifold.
|Analysis of PCR products before (b) and after (a) purification with the QIAquick PCR Purification Kit is shown. Samples were analyzed on a 1% TAE agarose gel. M: markers.|GelPilot Loading Dye contains three tracking dyes to facilitate optimization of DNA resolution.

|pH indicator dye in the solubilization and binding buffer allows easy visual determination of optimal pH for DNA adsorption (pH ≤7.5). An incorrect binding-mixture pH can occur if the agarose gel electrophoresis buffer was frequently used or incorrectly prepared. In this case, the pH can be easily adjusted by addition of 10 µl 3 M sodium acetate, pH 5.0.

|QIAvac 24 plus.
|QIAcube.
|Manifold with luer connectors.
|QIAvac 24.
|Microcentrifuge.
|
Performance
The QIAquick PCR Purification procedure removes primers, nucleotides, enzymes, mineral oil, salts, and other impurities from DNA samples (see figure "Complete primer removal after PCR"). Using a microcentrifuge or vacuum manifold, DNA ranging from 100 bp to 10 kb is purified.
Principle

QIAquick Kits contain a silica membrane assembly for binding of DNA in high-salt buffer and elution with low-salt buffer or water. The purification procedure removes primers, nucleotides, enzymes, mineral oil, salts, agarose, ethidium bromide, and other impurities from DNA samples (see figure "Complete primer removal after PCR"). Silica-membrane technology eliminates the problems and inconvenience associated with loose resins and slurries. Specialized binding buffers are optimized for specific applications and promote selective adsorption of DNA molecules within particular size ranges.

Gel loading dye

To enable faster and more convenient sample processing and analysis, gel loading dye is provided. GelPilot Loading Dye contains three tracking dyes (xylene cyanol, bromophenol blue, and orange G) to facilitate the optimization of agarose gel run time and prevent smaller DNA fragments migrating too far (see figure "GelPilot Loading Dye").

Procedure

The QIAquick system uses a simple bind-wash-elute procedure (see flowchart "QIAquick and MinElute procedure"). Binding buffer is added directly to the PCR sample or other enzymatic reaction, and the mixture is applied to the QIAquick spin column. The binding buffer contains a pH indicator, allowing easy determination of the optimal pH for DNA binding (see figure "pH Indicator Dye"). Nucleic acids adsorb to the silica membrane in the high-salt conditions provided by the buffer. Impurities are washed away and pure DNA is eluted with a small volume of low-salt buffer provided or water, ready to use in all subsequent applications.

Handling

QIAquick spin columns are designed to provide two convenient handling options. The spin columns fit into a conventional table-top microcentrifuge or onto any vacuum manifold with luer connectors, such as QIAvac 24 Plus with QIAvac Luer Adapters. The QIAquick PCR Purification Kit, in addition to other QIAGEN spin-column-based kits, can be fully automated on the QIAcube, enabling increased productivity and standardization of results (see figures "Spin column handling options A, B, C, D, and E").

Applications

DNA fragments purified with the QIAquick system are ready for direct use in all applications, including sequencing, microarray analysis, ligation and transformation, restriction digestion, labeling, microinjection, PCR, and in vitro transcription.

Feature
Specifications
Binding capacity 10 µg
Elution volume > 30 µl
Format Tube
Fragment size 100 bp – 10 kb
Fragments removed < 40mers
Processing Manual
Sample type: applications ssDNA or dsDNA from PCR and other enzymatic reactions
Technology Silica technology
Type(s) of DNA recovered ss DNA and dsDNA

FAQs
20
FAQ ID -786
View
FAQ ID -2791
View
FAQ ID -130
View
FAQ ID -575
View
FAQ ID -753
View
FAQ ID -577
View
FAQ ID -148
View
FAQ ID -311
View
FAQ ID -305
View
FAQ ID -637
View
FAQ ID -756
View
FAQ ID -205
View
FAQ ID -519
View
FAQ ID -199
View
FAQ ID -1745
View
FAQ ID -759
View
FAQ ID -490
View
FAQ ID -947
View
FAQ ID -180
View
FAQ ID -2460
View
User-Developed Protocols
1
The protocol has been used successfully for Cy3-, Cy5-, and biotin-labeling of cDNA from <50 ng of total RNA or poly A+ mRNA.
Show details